Citations

Clear

16 citation(s) found for "Harper, Laura".

Breast MRI in Patients With Active Implanted Metallic Devices: How We Do It
Sanders, Jeremiah , Panda, Anshuman , Harper, Laura, Patel, Bhavika , Sharpe, Richard, Sanders, Jeremiah W , Sharpe, Richard E.

Mayo Clinic

American Journal of Roentgenology | March 25, 2026 | Volume: 227 | Issue: 1 | Pages: No page available

10.2214/ajr.26.34661 | PMID 41879732 Get It

Positive Predictive Value and Breast Cancer Histology by the Method of Detection Across a Multistate Health Care Enterprise
Zhu, Alan , Harper, Laura, Maimone, S. I., Patel, Bhavika K, Girardo, Marlene E, Varner, Jacob, Rashid, Tariq , Khurana, A., Maimone, Santo , Patel, Bhavika , Khurana, Aditya , Harper, Laura , Maimone, Santo , Patel, Bhavika K , Khurana, Aditya , Sharpe, Richard E. , Girardo, Marlene

Mayo Clinic

Journal of Breast Imaging | December 23, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jbi/wbaf086 | PMID 41719116 Get It

Abstract Objective To compare the pathology outcomes of image-guided breast biopsies across a multistate health care enterprise by the method of detection (MOD), including the positive predictive value (PPV3) and histological types. Methods Biopsies from October 31, 2017, to July 6, 2023, across 18 imaging sites in 4 states were extracted. Radiologists prospectively assigned MODs, including symptomatic presentations (self-examination, clinical examination) and imaging modalities (mammogram, tomosynthesis, US, MRI, contrast-enhanced mammogram, molecular breast imaging, other imaging). For each MOD, the rates of malignancy and cancer subtypes were calculated. Univariate and multivariate logistic regression analyses were performed. Results In 26 932 biopsies on 22 582 patients (mean age 57.6 years ± 14.2 [SD]; 22 416 women), 6068 (81.1%) cancers were detected by screening, and 1144 (15.3%) were detected by symptoms. Symptomatic presentation MODs had a higher PPV3 (43.0% vs 25.6%; P < .001), larger cancer lesion sizes (x̄ = 27.5 mm vs x̄ = 17.8 mm; P < 001), and a higher association with invasive carcinoma (96.7% vs 76.8%; P <.001) compared with screening imaging-based MODs. Methods of detection with higher PPV3s also tended to have higher rates of invasive carcinoma (Spearman’s ρ = 0.83). Conclusion Compared with breast cancers detected after symptomatic presentations, those identified via image-based screening were smaller and less often invasive, confirming the value of screening in early detection. Positive predictive value and the rate of invasive carcinoma varied in parallel across MODs.
Relative Costs and Outcomes of a Contrast-Enhanced Mammography-Guided Biopsy Trial
Cumsky, Jameson , Mousa, Abeer, Zuley, Margarita L. , Harper, Laura K , Carnahan, Molly B. , Pizzitola, Victor J. , Ganott, Marie A., Nair, Bronwyn , Vargo, Adrienne , Harnist, Kimberly , Waheed, Uzma , Kelly, Amy E. , Harper, Laura , Harrison, Molly , Pizzitola, Victor, Waheed, Uzma , Patel, Bhavika K , Sharpe, Richard E. , Patel, Bhavika

Mayo Clinic

Journal of Breast Imaging | March 7, 2025 | Volume: 7 | Issue: 5 | Pages: 541-550

10.1093/jbi/wbaf019 | PMID 40393936 Get It

Abstract Objective To assess the performance and cost implications of contrast-enhanced mammography-guided biopsy (CEM Bx). Methods This is a prospective study from May 5, 2021, to April 18, 2022, across 2 U.S. academic centers, evaluating technical success, patient/radiologist feedback, and operational factors of CEM Bx. Inclusion criteria included that patients be 40 years or older and recommended for biopsy with suspicious findings on contrast-enhanced mammography (CEM). Descriptive statistics are reported for clinical outcomes, length of procedure, and user and participant feedback. An estimate of cost was made by comparing general Medicare costs that are being billed for CEM Bx and post-clip mammogram ($475.48) to the Medicare costs of MRI-guided biopsy (MRI Bx) and post-clip placement mammogram ($845.94). Results Eighty-two participants enrolled. Twenty-two were excluded at the time of CEM Bx (22/82, 27%). Sixty participants were included (mean age 57 years, range 33 to 81 years) with 63 suspicious CEM lesions. The malignancy rate was 22% (14/63). A technical success rate of 100% was achieved. Average CEM Bx time was 29% to 33% the average reported MRI-guided breast biopsy times (CEM Bx = 11 minutes; MRI Bx = 33 to 38 minutes), indicating operational efficiencies. A positive opinion of CEM Bx was reported by 78% of radiologists, 93% of technologists, and 98% of patients. The estimated cost for each CEM Bx was ~ 45% lower than MRI Bx. Conclusion CEM Bx demonstrates high success rates and satisfaction scores. CEM Bx resulted in shorter procedure times, enhanced operational efficiency, and ~45% reduction in costs compared with MRI Bx. As advancements continue, we anticipate CEM Bx will offer a cost-efficient and timely option for breast biopsy.
Cystic Breast Disease: What to Do When It’s Not So Cystic
Bhatt, Asha A. , Harper, Laura K , Anderson, Sarah , Solanki, Malvika , Ataya, Dana, Solanki, Malvika H

Mayo Clinic

Journal of Breast Imaging | January 15, 2025 | Volume: 7 | Issue: 2 | Pages: 233-248

10.1093/jbi/wbae079 | PMID 39809305 Get It

Abstract Cystic breast masses are a common entity encountered by breast radiologists. The imaging features of benign and malignant cystic masses may overlap, causing confusion and miscategorization with the potential to produce diagnostic delay and harm. This article provides a review of key differentiating imaging features that help guide appropriate mass characterization and treatment.
Digital Technologies Tracking Active and Passive Data Collection in Depressive Disorders: Lessons Learned From a Case Series
Gardea‐Resendez, Manuel , Breitinger, Scott , Harper, Laura , Stoppel, Cynthia , Volety, Rama , Raman, Jeyakumar, Byun, Jin Soo, Langholm, Carsten , Zandi, Peter P. , Frye, Mark A. , Xiong, Ashley , Volety, Rama M, Gardea-Resendez, Manuel , Walker, Alex, Raman, Jeyakumar, Goes, Fernando , Torous, John Blake

Mayo Clinic

Journal of Psychiatric Practice | December 10, 2024 | Volume: 30 | Issue: 6 | Pages: 434-439

10.1097/pra.0000000000000820 | PMID 39655971 Get It

In this case series, we present several examples from participants (2 patients and 1 healthy control) of a 12-week pilot feasibility study to create a digital phenotype of depression (unipolar or bipolar) through active and passive data collection from a smartphone and a wearable device combined with routine clinical care for mood disorders. The selected cases represent real clinical examples that highlight the intrinsic challenges that should be expected when conducting similar studies, including appropriate health data privacy protection, clinical standardization, and interindividual differences in levels of engagement and acceptability of active and passive data collection (ie, self-reported, behavioral, cognitive, and physiological data), particularly with patient-generated data in mobile apps, digital proficiency habituation, and consistent use of wearable devices. In the context of the rapidly growing use of digital technologies in psychiatry, anticipating challenges for the integration of personal mobile devices and smartphone mental health apps as aides to track specific aspects of depressive disorders is critical for a clinically meaningful digital transformation of mood disorders care.
Prospective Study of Supplemental Screening With Contrast-Enhanced Mammography in Women With Elevated Risk of Breast Cancer: Results of the Prevalence Round
Patel, Bhavika , Carnahan, Molly B. , Northfelt, Donald W. , Anderson, Karen S. , Mazza, Gina L. , Pizzitola, Victor J. , Giurescu, Marina E., Lorans, Roxanne, Eversman, William G. , Sharpe, Richard E. , Harper, Laura , Apsey, Heidi A., Palmieri, Jennifer, Fraker, Jessica , Mina, Lida A. , Pockaj, Barbara A. , Patel, Bhavika K , Northfelt, Donald , Harper, Laura K , Apsey, Heidi, Kling, Juliana M , Ernst, Brenda , Fraker, Jessica , Mina, Lida, Batalini, Felipe , Pockaj, Barbara, Mazza, Gina L , Harrison, Molly , Cronin, Patricia A. , Kling, Juliana M. , Ernst, Brenda , Batalini, Felipe

Mayo Clinic

Journal of Clinical Oncology | July 26, 2024 | Volume: 42 | Issue: 32 | Pages: 3826-3836

10.1200/jco.22.02819 | PMID 39058970 Get It

PURPOSE Contrast-enhanced mammography (CEM) and magnetic resonance imaging (MRI) have shown similar diagnostic performance in detection of breast cancer. Limited CEM data are available for high-risk breast cancer screening. The purpose of the study was to prospectively investigate the efficacy of supplemental screening CEM in elevated risk patients. MATERIALS AND METHODS A prospective, single-institution, institutional review board–approved observational study was conducted in asymptomatic elevated risk women age 35 years or older who had a negative conventional two-dimensional digital breast tomosynthesis screening mammography (MG) and no additional supplemental screening within the prior 12 months. RESULTS Four hundred sixty women were enrolled from February 2019 to April 2021. The median age was 56.8 (range, 35.0-79.2) years; 408 of 460 (88.7%) were mammographically dense. Biopsy revealed benign changes in 22 women (22/37, 59%), high-risk lesions in four women (4/37, 11%), and breast cancer in 11 women (11/37, 30%). Fourteen cancers (10 invasive, tumor size range 4-15 mm, median 9 mm) were diagnosed in 11 women. The overall supplemental cancer detection rate was 23.9 per 1,000 patients, 95% CI (12.0 to 42.4). All cancers were grade 1 or 2, ER+ ERBB2–, and node negative. CEM imaging screening offered high specificity (0.875 [95% CI, 0.844 to 0.906]), high NPV (0.998 [95% CI, 0.993 to 1.000), moderate PPV1 (0.164 [95% CI, 0.076 to 0.253), moderate PPV3 (0.275 [95% CI, 0.137 to 0.413]), and high sensitivity (0.917 [95% CI, 0.760 to 1.000]). At least 1 year of imaging follow-up was available on all patients, and one interval cancer was detected on breast MRI 4 months after negative screening CEM. CONCLUSION A pilot trial demonstrates a supplemental cancer detection rate of 23.9 per 1,000 in women at an elevated risk for breast cancer. Larger, multi-institutional, multiyear CEM trials in patients at elevated risk are needed for validation.
Biliary Disorders, Anomalies, and Malignancies in Children
Simmons, Curtis , Harper, Laura K , Patel, Mittun C. , Katabathina, Venkat S. , Southard, Richard , Gonçalves, Luís F. , Tran, Evelyn , Biyyam, Deepa R. , Simmons, Curtis L , Southard, Richard N , Goncalves, Luis

Mayo Clinic

RadioGraphics | February 15, 2024 | Volume: 44 | Issue: 3 | Pages: No page available

10.1148/rg.230109 | PMID 38358937 Get It

False-Positive and False-Negative Contrast-enhanced Mammograms: Pitfalls and Strategies to Improve Cancer Detection
Carnahan, Molly B. , Harper, Laura K , Brown, Parker J. , Bhatt, Asha A. , Eversman, Sarah , Sharpe, Richard E. , Patel, Bhavika , Harper, Laura , Patel, Bhavika K , Harrison, Molly

Mayo Clinic

RadioGraphics | November 30, 2023 | Volume: 43 | Issue: 12 | Pages: No page available

10.1148/rg.230100 | PMID 38032823 Get It

Imaging Characteristics of and Multidisciplinary Management Considerations for Atypical Ductal Hyperplasia and Flat Epithelial Atypia: Review of Current Literature
Harper, Laura K , Carnahan, Molly B. , Bhatt, Asha A. , Simmons, Curtis , Patel, Bhavika , Downs, Erinn , Pockaj, Barbara A. , Yancey, Kristina , Eversman, Sarah , Sharpe, Richard E. , Simmons, Curtis L , Patel, Bhavika K , Eversman, Sarah E, Harrison, Molly

Mayo Clinic

RadioGraphics | September 28, 2023 | Volume: 43 | Issue: 10 | Pages: No page available

10.1148/rg.230016 | PMID 37768862 Get It

How to Recognize and Correct Artifacts on Contrast-Enhanced Mammography
Harper, Laura K , Faulk, Ellen A, Patel, Bhavika , Collins, Patricia, Rochman, Carrie M., Patel, Bhavika K

Mayo Clinic

Journal of Breast Imaging | July 28, 2023 | Volume: 5 | Issue: 4 | Pages: 486-497

10.1093/jbi/wbad041 | PMID 38416909 Get It

Abstract Contrast-enhanced mammography (CEM) has emerged as an important new technology in breast imaging. It can demonstrate a number of imaging artifacts that have the potential to limit interpretation by either obscuring or potentially mimicking disease. Commonly encountered artifacts on CEM include patient motion artifacts (ripple and misregistration), pectoral highlighting artifact, breast implant artifact, halo artifact, corrugation artifact, cloudy fat artifact, contrast artifacts (retention and contamination), skin artifacts (skin line enhancement and skin overexposure), and skin lesions. Skin lesions may demonstrate a variety of imaging appearances and have both benign and malignant etiologies. It is important that the technologist, radiologist, and physicist be aware of potential artifacts and skin enhancement on CEM that may affect interpretation and understand their causes and potential solutions.