Citations

Clear

21 citation(s) found for "Frick, Matthew".

Complementary Role of Whole-Body MRI and CT in Hematologic Malignancies and Bone Marrow Disorders
Ghotbi, Elena, Frick, Matthew, Cook, Joselle, Baffour, Francis , Baffour, Francis I , Frick, Matthew J. , Cook, Joselle

Mayo Clinic

Journal of Computer Assisted Tomography | July 22, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/rct.0000000000001918 | PMID 42483998 Get It

Whole-body cross-sectional imaging has largely replaced skeletal survey as the standard for evaluating hematologic malignancies and bone marrow disorders, but the practical choice between whole-body low-dose CT (WBCT) and whole-body MRI (WBMRI) remains incompletely resolved. This clinical review provides a practical, scenario-based comparison of WBCT and WBMRI across diagnosis, staging, treatment response, and surveillance. We emphasize real-world practical considerations, including scanner access, expertise, patient tolerance, radiation considerations, and cost. In multiple myeloma, with available comparative evidence, we include a focused research synthesis of 3 studies (152 patients) demonstrating high pooled CT-MRI concordance of 0.895 (95% CI: 0.834-0.935) with no detectable heterogeneity ( I 2 =0%), supporting either modality as a reasonable first-line depending on the clinical question. Across all included disease categories, the broader pooled concordance estimate was 0.797 (95% CI: 0.667-0.885) with substantial heterogeneity reflecting variability in clinical context, reference standard, and protocol. WBMRI dominates in non-neoplastic marrow disorders where marrow characterization is essential. In lymphoma, FDG-PET/CT remains the standard for adult disease, with WBMRI most indicated in pediatrics and adolescents. Emerging CT techniques, including dual-energy CT with virtual noncalcium images and photon-counting detector CT, are extending CT into the marrow imaging space and narrowing the historical gap with MRI. Modality selection should be guided by the specific clinical scenario, available resources, and patient factors rather than by global judgments of modality superiority.
Radiological Insights into Alcohol Use-Associated Disorders and Diseases: Part II
Nduwimana, Marie-Joy, Patil, Aruna R., Kolbe, Amy B. , Frick, Matthew A., Khandelwal, Ashish , Venkatesh, Sudhakar K. , Venkatesh, Sudhakar K , Bathla, Girish , Rajiah, Prabhakar

Mayo Clinic

Indian Journal of Radiology and Imaging | February 14, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0046-1815931 Get It

Alcohol use disorder (AUD) is a preventable non-communicable disease that affects multiple organs and organ systems across all age groups, including the fetus and is a risk factor for developing certain cancers. Furthermore, alcohol intoxication can result in physical trauma to oneself and others, and is a contributing factor in road accidents. Early recognition of AUD is critical for improving diagnosis, management, and outcomes. Accurate diagnosis relies on comprehensive clinical evaluation and patient history. However, denial of AUD, inebriation, and lack of awareness of problems associated with AUD, can prevent early identification of the disease. AUD-associated organ damage manifests in several ways and can be recognized on imaging modalities including ultrasound, CT, and MRI. Detection of these imaging features is useful in raising suspicion of AUD or diagnosing chronic alcohol use. Radiologists should be aware of the manifestations of alcohol's effects across various organ systems and aid in the early detection and treatment of AUD. In this two-part review, the authors present a comprehensive image-based review illustrating the effects of AUD on different organ systems at various stages. This second part focuses on the imaging manifestations in the central nervous system, fetal health, cardiovascular system, and musculoskeletal system. Additionally, a brief overview of secondary imaging manifestations of alcohol use, associated with trauma and cancers, will be presented.
Imaging Manifestations of Alcohol Use–associated Disorders and Diseases
Venkatesh, Sudhakar K. , Bathla, Girish , Caserta, Melanie P. , Brown, Mark F., Frick, Matthew A., Kolbe, Amy B. , Sheedy, Shannon P. , Khandelwal, Ashish , Fidler, Jeff L. , Brown, Mark , Kolbe, Amy , Rajiah, Prabhakar , Fidler, Jeff L. , Venkatesh, Sudhakar K , Bathla, Girish , Khandelwal, Ashish , Rajiah, Prabhakar

Mayo Clinic

RadioGraphics | June 5, 2025 | Volume: 45 | Issue: 7 | Pages: No page available

10.1148/rg.240189 | PMID 40471832 Get It

Alcohol use disorder is linked to a multitude of diseases and disorders, many of which can be diagnosed with imaging techniques such as US, CT, and MRI, enabling early detection and potentially preventing further damage and improving outcomes.
A phase 1 clinical trial shows safe, sustained, AAV-mediated expression of IL-1Ra in the human osteoarthritic knee joint
Vega, Rodolfo E. De la , Sellon, Jacob L. , Smith, Jay , Wisniewski, Stephen, Jurisson, Mary L. , Frick, Matthew A., Scrabeck, Tyson L., Block, Julie B., Mills, Candee J. , Pohlkamp, Zachary W., Coenen, Michael J., Hawse, Gresin P. , Abdul, Temilola Y. , Conaghan, Philip G. , Keravala, Annahita, Robbins, Paul D. , Ghivizzani, Steven C. , Evans, Christopher H. , De La Vega, Rodolfo E , Wisniewski, Stephen J, Conaghan, Philip , Chalberg, Thomas W , Robbins, Paul D , Ghivizzani, Steven C , Evans, Christopher H , Block, Julie B.

Mayo Clinic

Science Translational Medicine | June 4, 2025 | Volume: 17 | Issue: 801 | Pages: No page available

10.1126/scitranslmed.adu9804 | PMID 40465688 Get It

Osteoarthritis (OA) is a major global health problem with no disease-modifying therapies. Interleukin-1 (IL-1) is a critical cytokine associated with the pathophysiology of OA and can be inhibited by IL-1 receptor antagonist (IL-1Ra). Here, we tested the delivery of a gene therapeutic encoding the human IL-1Ra to the knee in a phase 1, open-label clinical trial that enrolled nine patients with radiographic knee OA. The IL-1Ra gene was delivered by a self-complementary (sc)–recombinant adeno-associated virus (rAAV) serotype 2.5 (sc-rAAV2.5IL-1Ra) by intra-articular injection into an index knee at one of three doses: low [1 × 10 11 viral genomes (vg)], mid (1 × 10 12 vg), or high (1 × 10 13 vg). The primary outcome was safety. There were no serious adverse events (AEs) related to sc-rAAV2.5IL-1Ra. Two AEs occurred that were possibly related to the vector. Both were effusions with increased pain and resolved with conservative treatment. sc-rAAV2.5IL-1Ra did not cause changes in vital signs, physical findings, or clinical laboratory measures. Less than 1% of the injected dose of sc-rAAV2.5IL-1Ra vg was detected in circulation after 1 day and was cleared within a week. Titers of neutralizing antibodies to AAV2.5 rose in serum and synovial fluid. In all cases, IL-1Ra concentration increased in the synovial fluid, and IL-1Ra concentrations remained elevated after 1 year. Baseline pain and function scores improved during the study. Therefore, we found that intra-articular gene therapy with sc-rAAV2.5IL-1Ra was safe. The sustained increase in local IL-1Ra in human knee joints supports the further clinical examination of this therapy to provide therapeutic benefit in OA.
RCOM RADIOLOGICAL CASE OF THE MONTH
L., Emery Robert, Ly, Justin Q. , Frick, Matthew D., Hoffman, Alan D., Beall, Douglas P.

Mayo Clinic

Applied Radiology | April 2, 2022 | Volume: No volume available | Issue: No issue available | Pages: 49-52

10.37549/ar1198 Get It

High-resolution MRI of a peroneal intraneural ganglion cyst arising from the knee joint: illustrative case
Jack, Megan M. , Powell, Garret M. , Frick, Matthew A., Amrami, Kimberly K. , Spinner, Robert J. , Smith, Brandon W.

Mayo Clinic

Journal of Neurosurgery: Case Lessons | May 24, 2021 | Volume: 1 | Issue: 21 | Pages: No page available

10.3171/case21130 | PMID 35854869 Get It

BACKGROUND The advancement of high-resolution imaging and increased clinical experience have led to an increased understanding of the formation and treatment of intraneural ganglion cysts. Nearly all intraneural ganglion cysts in the common peroneal nerve have been reported to arise from a joint connection to the superior tibiofibular joint. The authors have identified four cases of intraneural ganglion cysts arising from the knee joint itself; however, none of these reported cases were well described, documented, or illustrated with high-resolution imaging. OBSERVATIONS Here the authors present the case of an intraneural ganglion cyst arising from the knee joint and causing intermittent weakness and pain. The articular branch to the knee joint was clearly demonstrated on high-resolution magnetic resonance imaging and confirmed at surgical exploration. The patient was treated with articular branch ligation and has had complete resolution of his symptoms without recurrence of the cyst on follow-up imaging. LESSONS This case adds to the mounting evidence that intraneural cyst pathology is dependent on a connection to a synovial joint as stated in the unifying theory of intraneural cyst development.
Clinical and Radiological Safety of Retained Implantable Doppler Devices Used for Free Flap Monitoring
Kreutz‐Rodrigues, Lucas , Carlsen, Brian T. , Frick, Matthew A., Bakri, Karim , Gibreel, Waleed , Mardini, Samir

Mayo Clinic

Plastic Surgery | April 27, 2021 | Volume: 30 | Issue: 1 | Pages: 20-24

10.1177/22925503211006537 | PMID 35096688 Get It

Introduction: Implantable Doppler devices are reliable adjuncts used for free flap monitoring. Occasionally, the probe/wire is not removed and remains in the soft tissues. The clinical safety of the retained probes and safety and compatibility with magnetic resonance imaging (MRI) have not been studied. We present a series of retained implantable Doppler probes examining clinic outcomes, safety and compatibility with MRI, and effect on MRI image quality. Methods: A retrospective review was conducted of patients who had an implantable Doppler device for free flap monitoring between July 2007 and August 2018. Routine post-operative imaging was reviewed for all patients to identify incidental findings of a retained probe. A subset of patients with retained implantable Doppler probes who underwent MRI was identified. Magnetic resonance images were reviewed to detect any degradation of image quality. Results: A total of 323 patients who had an implantable Doppler device placed were reviewed 18 (5.6%) patients were identified with a retained probe and were included in this study. Mean age was 49 years with mean follow-up of 34.4 months. One potential device-related complication occurred in 1 (5.6%) patient. A total of 32 MRI scans were performed in 8 patients with retained devices, including 6 patients who underwent a total of 21 MRIs of the surgical site. There were no complications related to the MRI scans, and we found no significant degradation of image quality. Conclusion: Retained implantable Doppler probes were not associated with substantial adverse clinical outcomes nor affected MRI image quality of the surgical site.
7T MR Thermometry technique for validation of system‐predicted SAR with a home‐built radiofrequency wrist coil
Fagan, Andrew , Jacobs, Paul , Hulshizer, Thomas C., Rossman, Phillip J. , Frick, Matthew A., Amrami, Kimberly K. , Felmlee, Joel P. , Jacobs, Paul S, Fagan, Andrew J

Mayo Clinic

Medical Physics | December 10, 2020 | Volume: 48 | Issue: 2 | Pages: 781-790

10.1002/mp.14641 | PMID 33294999 Get It

PurposeA 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system‐measured transmitted radiofrequency (RF) power into a home‐built RF wrist coil with the system‐predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g‐averaged specific absorption rate (SAR10g), are not exceeded. MRT can be used to validate this factor by ensuring that MRT‐measured SAR values do not exceed those predicted by the system.MethodsA 14‐cm diameter high‐pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual‐echo gradient echo MRT technique, incorporating quasi‐simultaneous RF‐induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high‐temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4‐min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility‐induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1+ maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist‐sized piece of meat positioned at that SAR hotspot location. MRT‐measured and system‐predicted SAR values for the phantom and meat were compared.ResultsTemperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT‐measured B1+ and SAR maps. Using a coil conversion factor of 2 kg−1, MRT‐measured point‐SAR values did not exceed the system‐predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location.ConclusionsA highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system‐predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.
Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT
Murthy, Naveen S. , Frick, Matthew A., Tao, Shengzhen , Unger, Mark, LaVallee, Katherine T, Larson, Nicholas B. , Maus, Timothy P. , Larson, Nicholas B , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Mayo Clinic

Investigative Radiology | January 27, 2020 | Volume: 55 | Issue: 6 | Pages: 349-356

10.1097/rli.0000000000000648 | PMID 31985604 Get It

Objective The aim of this study was to grade cartilage damage in a swine model of osteoarthritis using a whole-body photon-counting detector (PCD) CT. Materials and Methods A multienergy phantom containing gadolinium (Gd) (2, 4, 8, and 16 mg/mL) and hydroxyapatite (200 and 400 mg/cc) was scanned using a PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs, D50 reconstruction kernel) to serve as calibration for material decomposition and to assess quantification accuracy. Osteoarthritis was induced in Yucatan miniswine (n = 8) using 1.2 mg monoiodoacetate (MIA) injected into a randomized knee, whereas the contralateral control knee received saline. Twenty-one days later, a contrast bolus (gadoterate meglumine, 4 mL/knee) was intra-articularly administered into both knees. The knees were simultaneously scanned on the PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs). Multienergy images were reconstructed with a sharp “V71” kernel and a quantitative “D50” kernel. Image denoising was applied to the V71 images before grading cartilage damage, and an iterative material decomposition technique was applied to D50 images to generate the Gd maps. Two radiologists blinded to the knee injection status graded the cartilage integrity based on a modified International Cartilage Repair Society scoring system. Histology was performed on excised cartilage using methylene blue/basic fuchsin. Statistical analysis of grade distribution was performed using an exact test of omnibus symmetry with P < 0.05 considered significant. Results Material decomposed images from the multienergy phantom scan showed delineation and quantification of Gd and hydroxyapatite with a root-mean-squared error of 0.3 mg/mL and 18.4 mg/cc, respectively. In the animal cohort, the radiologists reported chondromalacia in the MIA knees with International Cartilage Repair Society scores ranging from grade 1 (cartilage heterogeneity, n = 4 knees) to grade 3 (up to 100% cartilage loss, n = 4 knees). Grade 1 was characterized by cartilage heterogeneity and increased joint space in the patellofemoral compartment, whereas grade 3 was characterized by cartilage erosion and bone-on-bone articulation in the patellofemoral compartment. All control knees were scored as grade 0 (normal cartilage). Significant difference (P = 0.004) was observed in the grade distribution between the MIA and control knees. Gross examination of the excised knees showed cartilage lesions in the grade 3 MIA knees. The Gd maps from material decomposition showed lower contrast levels in the joint space of the MIA knee compared with the contralateral control knee due to joint effusion. Histology revealed chondrocyte loss in the MIA knee cartilage confirming the chondrotoxic effects of MIA on cartilage matrix. Conclusions We demonstrated a high-resolution and quantitative PCD-CT arthrography technique for grading cartilage damage in a large animal model of osteoarthritis. Photon-counting detector CT offers simultaneous high-resolution and multienergy imaging capabilities that allowed morphological assessment of cartilage loss and quantification of contrast levels in the joint as a marker of joint disease. Cartilage damage in the MIA knees was graded using PCD-CT images, and the image-based findings were further confirmed using histology and gross examination of the excised knees.
Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode
Fagan, Andrew , Welker, Kirk M. , Amrami, Kimberly K. , Frick, Matthew A., Watson, Robert E. , Kollasch, Peter , Chebrolu, Venkata V. , Felmlee, Joel P. , Fagan, Andrew J

Mayo Clinic

Investigative Radiology | September 10, 2019 | Volume: 54 | Issue: 12 | Pages: 781-791

10.1097/rli.0000000000000598 | PMID 31503079 Get It

Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.