Citations

Institution: Mayo Clinic Clear

Showing 10 of 108104 citations.

Perceptions and Practices of Therapeutic Hypothermia in American Neonatal Intensive Care Units
Harris, Malinda N. , Ellsworth, Marc A., Haas, Lindsey R., Hartman, Tyler, Lang, Tara R., Colby, Christopher E. , Carey, William A.

American Journal of Perinatology | March 2, 2013 | Volume: 31 | Issue: 01 | Pages: 015-020

10.1055/s-0033-1334454 | PMID 23456901 Get It

Projecting future drug expenditures in U.S. nonfederal hospitals and clinics—2013
Hoffman, James M. , Li, Edward , Doloresco, Fred, Matusiak, Linda M., Hunkler, Robert J., Shah, Nilay D., Vermeulen, Lee C. , Schumock, Glen T.

American Journal of Health-System Pharmacy | March 2, 2013 | Volume: 70 | Issue: 6 | Pages: 525-539

10.2146/ajhp120759 | PMID 23456407 Get It

Systematic Psychiatric Evaluation: A Step-by-Step Guide to Applying the Perspectives of Psychiatry
Alarcón, Renato D.

American Journal of Psychiatry | March 2, 2013 | Volume: 170 | Issue: 3 | Pages: 343-344

10.1176/appi.ajp.2012.12111380 Get It

Systemic Amyloidoses
Blancas‐Mejía, Luis M. , Ramı́rez-Alvarado, Marina , Ramirez-Alvarado, Marina

Annual Review of Biochemistry | March 2, 2013 | Volume: 82 | Issue: 1 | Pages: 745-774

10.1146/annurev-biochem-072611-130030 | PMID 23451869 Get It

The amyloidoses are a group of protein misfolding diseases in which the precursor protein undergoes a conformational change that triggers the formation of amyloid fibrils in different tissues and organs, causing cell death and organ failure. Amyloidoses can be either localized or systemic. In localized amyloidosis, amyloid deposits form at the site of precursor protein synthesis, whereas in systemic amyloidosis, amyloid deposition occurs distant from the site of precursor protein secretion. We review the type of proteins and cells involved and what is known about the complex pathophysiology of these diseases. We focus on light chain amyloidosis to illustrate how biochemical and biophysical studies have led to a deeper understanding of the pathogenesis of this devastating disease. We also review current cellular, tissue, and animal models and discuss the challenges and opportunities for future studies of the systemic amyloidoses.
Application of Radiation Force in Noncontact Measurement of the Elastic Parameters
Greenleaf, James F. , Fatemi, Mostafa

Ultrasonic Imaging | March 2, 2013 | Volume: 21 | Issue: 2 | Pages: 147-154

10.1177/016173469902100205 | PMID 10485567 Get It

Ultrasound-stimulated vibro-acoustic spectrography is a recently-developed method that employs the radiation force of two intersecting continuous ultrasound beams to remotely vibrate an object at an arbitrary low frequency. Object vibration produces a sound field (acoustic emission) in the medium, which is a function of object mechanical properties. By measuring the acoustic emission field, one can obtain information about the mechanical parameters of the object. In this paper, we use this method for remote (noncontact) measurement of the dynamic Young's modulus of a rod based on its fundamental resonance frequency. Experimental results on an aluminum rod agree with the published data.
Detection of Cardiac Boundaries in Echocardiographic Images Using a Customized Order Statistics Filter
Bëlohlávek, Marek , Greenleaf, James F.

Ultrasonic Imaging | March 2, 2013 | Volume: 19 | Issue: 2 | Pages: 127-137

10.1177/016173469701900203 | PMID 9381629 Get It

Order statistics filters are nonlinear filters that suppress impulsive and Gaussian noise while preserving edges. These features are particularly useful for cardiac boundary detection in ultrasound images. Based on these facts, we have analyzed performance of a combined ranked order statistics filter. The filter subtracts ranks of ordered highest and lowest intensity values of pixels encompassed in a filter window. The rank extent and window size selection allow adjustment of filter properties for a particular application. Increasing the rank fosters the low-pass characteristics of the filter. Increasing the window size supports noise removal but reduces anatomic selectivity. The filter highlights cardiac boundaries in clinical echocardiograms with intensity proportional to the local probability of a presence of the boundary.
Producing Deep Depth of Field and Depth-Independent Resolution in Nde with Limited Diffraction Beams
Lu, Jian-yu, Greenleaf, James F.

Ultrasonic Imaging | March 2, 2013 | Volume: 15 | Issue: 2 | Pages: 134-149

10.1177/016173469301500205 | PMID 8346611 Get It

Limited diffraction beams, such as Durnin's J 0 Bessel beam, are a class of nonspreading solutions to the isotropic/homogeneous scalar wave equation. These beams can be approximately produced with finite aperture and energy over a deep depth of field. In this paper, we report the application of a broadband J 0 Bessel beam to nondestructive evaluation (NDE) of materials. Pulse-echo images of a stainless steel block phantom were obtained with both the Jo Bessel beam and a conventional focused Gaussian beam. Results show that uniformly high resolutions were obtained with the J 0 Bessel beam over a large distance. In addition, the lateral resolution of the J 0 Bessel beam is almost independent of the speed of sound of the materials inspected. In contrast, the lateral resolution of images obtained with the conventional focused Gaussian beam changes dramatically with the distance and the focal length of the beam in water is greatly reduced by the steel block. Therefore, limited diffraction beams could be useful for nondestructive evaluation of materials of different speeds of sound. Restoration of pulse-echo images obtained with these beams could be simplified.
Modified X Waves with Improved Field Properties
Lu, J-y., Greenleaf, James F. , Song, Tai‐Kyong

Ultrasonic Imaging | March 2, 2013 | Volume: 15 | Issue: 1 | Pages: 36-47

10.1177/016173469301500104 | PMID 8328118 Get It

A method to obtain a good compromise between the depth of field and the lateral resolution of “X waves” is proposed. The original X waves are theoretically nondiffracting beams generated by a specially phased infinite transmit aperture. When generated by a finite aperture, X waves are diffracting beams but have a large depth of field, maintaining uniform lateral field profiles. The proposed modification of the wave equation solution for X waves replaces a constant parameter representing the propagation angle of ultrasound with a function of radial distance at the aperture surface, and results in modified X waves that have a larger depth of field than the original X waves. Computer simulations show that a proper choice of the modification function can produce a new beam with improved field properties compared with the original X waves, promising images with higher lateral resolution and increased contrast over a large depth of field in high frame rate medical imaging. Experimental results are presented to verify the simulation results of the proposed method.
Spectral Normalization for Ultrasonic Contrast Microbubble Detection
Chen, Shigao , McMahon, Eileen M. , Greenleaf, James F. , Bëlohlávek, Marek , Fatemi, Mostafa

Ultrasonic Imaging | March 2, 2013 | Volume: 26 | Issue: 3 | Pages: 150-162

10.1177/016173460402600302 | PMID 15754796 Get It

Ultrasonic contrast agents consisting of microbubbles are used to assess tissue perfusion. The microbubbles are highly reflective and nonlinear and thus produce harmonics that are stronger than those from tissues. However, the magnitude of harmonic signals resulting from a region with microbubbles also depends on the acoustic pressure of incident ultrasound and the attenuation of intervening tissues in the ultrasound path. Therefore, the harmonic magnitude, as used in traditional harmonic imaging, may not be a reliable indicator of the presence or absence of microbubbles, and hence, tissue perfusion. To compensate for these effects, we present two parameters defined as the ratio of the harmonic to the fundamental component ( HFR) and the ratio of the harmonic to squared fundamental ( HSFR). A simplified model is used to illustrate the usefulness of these two parameters. Experiments show that both parameters improve detection of microbubbles and that HSFR performs better than HFR.
Linear Arrays for Vibro-Acoustography: A Numerical Simulation Study
Silva, Glauber T. , Greenleaf, James F. , Fatemi, Mostafa

Ultrasonic Imaging | March 2, 2013 | Volume: 26 | Issue: 1 | Pages: 1-17

10.1177/016173460402600101 | PMID 15134390 Get It

In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave or tone-burst signals at slightly different frequencies. The system beamforming is modeled in a homogeneous and lossless fluid. In this model, the point-spread function (psf) of the system is obtained as the product of the spatial impulse function of each linear array. Three linear array configurations are analyzed for vibro-acoustography systems. Simulations considering 64 elements in each array are performed. Aspects related to clinical applications of vibro-acoustography, such as system spatial resolution, sidelobes, grating lobes and image frame-rate are discussed. It is concluded that linear array transducers can produce acceptable spatial resolution for clinical applications.