Citations

Institution: Mayo Clinic Clear

Showing 10 of 108195 citations.

Mild cognitive impairment as a risk factor for Parkinson's disease dementia
Hoogland, Jeroen , Boel, Judith A., Bie, Rob M.A. de , Geskus, Ronald B. , Schmand, Ben , Dalrymple‐Alford, John C. , Goldman, Jennifer G. , Tröster, Alexander I. , Burn, David J. , Geurtsen, Gert J. , Disease”, on behalf of the MDS Study Group “Validation of Mild Cognitive Impairment in Parkinson, Rodríguez‐Oroz, María , Goldman, Jennifer G , Marras, Connie , Adler, Charles H. , Litvan, Irene , Disease”, on behalf of the MDS Study Group “Validation of Mild Cognitive Impairment in Parkinson, Dalrymple-Alford, John C , de Bie, Rob M A , Geurtsen, Gert J

Movement Disorders | June 12, 2017 | Volume: 32 | Issue: 7 | Pages: 1056-1065

10.1002/mds.27002 | PMID 28605056 Get It

ABSTRACT Background The International Parkinson and Movement Disorder Society criteria for mild cognitive impairment in PD were recently formulated. Objectives The aim of this international study was to evaluate the predictive validity of the comprehensive (level II) version of these criteria by assessment of their contribution to the hazard of PD dementia. Methods Individual patient data were selected from four separate studies on cognition in PD that provided information on demographics, motor examination, depression, neuropsychological examination suitable for application of level II criteria, and longitudinal follow‐up for conversion to dementia. Survival analysis evaluated the predictive value of level II criteria for cognitive decline toward dementia as expressed by the relative hazard of dementia. Results A total of 467 patients were included. The analyses showed a clear contribution of impairment according to level II mild cognitive impairment criteria, age, and severity of PD motor symptoms to the hazard of dementia. There was a trend of increasing hazard of dementia with declining neuropsychological performance. Conclusions This is the first large international study evaluating the predictive validity of level II mild cognitive impairment criteria for PD. The results showed a clear and unique contribution of classification according to level II criteria to the hazard of PD dementia. This finding supports their predictive validity and shows that they contribute important new information on the hazard of dementia, beyond known demographic and PD‐specific factors of influence. © 2017 International Parkinson and Movement Disorder Society
Generation and measurement of shear waves in micellar fluids using ultrasound-based methods
Amador, Carolina , Otilio, Bruno L., Kinnick, Randall R., Urban, Matthew W.

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3887-3887

10.1121/1.4988714 Get It

Wormlike micellar fluids are viscoelastic and their mechanical properties have been evaluated with mechanically generated shear waves combined with optical detection as well as rheological testing. In this work, we describe the use of acoustic radiation force and ultrafast ultrasound imaging to generate shear waves and measure their propagation, respectively. This shear wave elastography (SWE) method has been used to measure the viscoelastic mechanical properties in tissue-mimicking phantoms and soft tissues. We tested micellar fluids made from cetrimonium bromide (CTAB) and sodium salicylate (NaSAL) with a 5:3 ratio with different concentrations (100, 200, 300, and 400 mM). We fit an extended Maxwell model to the rheological test data (0.001-15.91Hz) and used the model parameters to calculate the shear wave phase velocity in the range of the SWE data (100-500 Hz). The phase velocities calculated from the rheology testing compared well with the SWE results. The mean absolute error was less than 0.02 m/s for all the micellar fluids tested. The SWE method is nondestructive and can be used for characterization of the viscoelasticity of micellar fluids, which could be used as a model for biological tissues. [This work was supported in part by grant R01DK092255.]
Clinical trials evaluating potential therapies for light chain (AL) amyloidosis
Muchtar, Eli , Gertz, Morie A. , Muchtar, E

Expert Opinion on Orphan Drugs | June 10, 2017 | Volume: 5 | Issue: 8 | Pages: 655-663

10.1080/21678707.2017.1341834 | PMID 34567849 Get It

Allogeneic MSCs and Recycled Autologous Chondrons Mixed in a One-Stage Cartilage Cell Transplantion: A First-in-Man Trial in 35 Patients
Windt, Tommy S. de , Vonk, Luciënne A. , Slaper‐Cortenbach, Ineke , Nizak, Razmara, Rijen, Mattie H.P. van , Saris, Daniël B.F. , de Windt, Tommy S , Vonk, Lucienne A

Stem Cells | June 10, 2017 | Volume: 35 | Issue: 8 | Pages: 1984-1993

10.1002/stem.2657 | PMID 28600828 Get It

AbstractMSCs are known as multipotent mesenchymal stem cells that have been found capable of differentiating into various lineages including cartilage. However, recent studies suggest MSCs are pericytes that stimulate tissue repair through trophic signaling. Aimed at articular cartilage repair in a one-stage cell transplantation, this study provides first clinical evidence that MSCs stimulate autologous cartilage repair in the knee without engrafting in the host tissue. A phase I (first-in-man) clinical trial studied the one-stage application of allogeneic MSCs mixed with 10% or 20% recycled defect derived autologous chondrons for the treatment of cartilage defects in 35 patients. No treatment-related serious adverse events were found and statistically significant improvement in clinical outcome shown. Magnetic resonance imaging and second-look arthroscopies showed consistent newly formed cartilage tissue. A biopsy taken from the center of the repair tissue was found to have hyaline-like features with a high concentration of proteoglycans and type II collagen. DNA short tandem repeat analysis delivered unique proof that the regenerated tissue contained patient-DNA only. These findings support the hypothesis that allogeneic MSCs stimulate a regenerative host response. This first-in-man trial supports a paradigm shift in which MSCs are applied as augmentations or “signaling cells” rather than differentiating stem cells and opens doors for other applications.
Inducible knockdown of pregnancy‐associated plasma protein‐A gene expression in adult female mice extends life span
Bale, Laurie K., West, Sally A., Conover, Cheryl A.

Aging Cell | June 10, 2017 | Volume: 16 | Issue: 4 | Pages: 895-897

10.1111/acel.12624 | PMID 28600811 Get It

SummaryPregnancy‐associated plasma protein‐A (PAPP‐A) knockout (KO) mice, generated through homologous recombination in embryonic stem cells, have a significantly increased lifespan compared to wild‐type littermates. However, it is unknown whether this longevity advantage would pertain to PAPP‐A gene deletion in adult animals. In the present study, we used tamoxifen (Tam)‐inducible Cre recombinase‐mediated excision of the floxed PAPP‐A (fPAPP‐A) gene in mice at 5 months of age. fPAPP‐A mice, which were either positive (pos) or negative (neg) for Tam‐Cre, received Tam treatment with quarterly boosters. Only female mice could be used with this experimental design. fPAPP‐A/neg and fPAPP‐A/pos mice had similar weights at the start of the experiment and showed equivalent weight gain. We found that fPAPP‐A/pos mice had a significant extension of life span (P = 0.005). The median life span was increased by 21% for fPAPP‐A/pos compared to fPAPP‐A/neg mice. Analysis of mortality in life span quartiles indicated that the proportion of deaths of fPAPP‐A/pos mice were lower than fPAPP‐A/neg mice at young adult ages (P = 0.002 for 601–800 days) and higher than fPAPP‐A/neg mice at older ages (P = 0.004 for >1000 days). Thus, survival curves and age‐specific mortality indicate that female mice with knockdown of PAPP‐A gene expression as adults have an extended healthy life span.
Shear elasticity and shear viscosity imaging in viscoelastic phantoms
Yang, Yiqun , McGough, Robert J., Song, Pengfei , Chen, Shigao , Urban, Matthew W.

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3720-3721

10.1121/1.4988148 Get It

Shear wave elasticity imaging determines the mechanical parameters of soft tissue by analyzing measured shear waves induced by an acoustic radiation force. Currently, the widely used time-of-flight method calculates the correlation between shear waveforms at adjacent lateral observation points to estimate the shear elasticity value. Although this method provides accurate estimates of the shear elasticity in purely elastic media, our experience suggests that this approach overestimates the shear elasticity values in viscoelastic media because the effects of diffraction, attenuation, and dispersion are not taken into account. To address this problem, we have developed an approach that directly accounts for all of these effects when estimating the shear elasticity. This new approach simulates shear waveforms using a Green’s function-based approach with a Voigt model, while the shear elasticity and viscosity values are estimated using an optimization-based approach by comparing measured shear waveforms with simulated shear waveforms in the time-domain. This operation is then performed on a point-by-point basis to generate images. The results indicate that there is good agreement between the simulated and measured shear velocity waveforms, and that this approach yields improved images of the shear elasticity and shear viscosity. [Work supported, in part, by NIH Grant R01DK092255.]
Shear wave phase velocity dispersion estimation in viscoelastic materials using the Multiple Signal Classification method
Qiang, Bo, Amador, Carolina , Urban, Matthew W. , Kijanka, Piotr , Song, Pengfei , Chen, Shigao

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3720-3720

10.1121/1.4988145 Get It

Shear wave elastography (SWE) is clinically used for the measurement of soft tissue mechanical properties. Most SWE methods assume that the tissue is elastic, but soft tissues are inherently viscoelastic. The viscoelasticity can be characterized by examining phase velocity dispersion. Methods to extract the phase velocities from the spatiotemporal data, v(x,t), involve using a two-dimensional Fourier transform. The Fourier representation, V(k,f), is searched for peaks that correspond to the phase velocities. We present a method that uses the Multiple Signal Classification (MUSIC) method to provide robust estimation of the phase velocity dispersion curves. We compared results from the MUSIC method with the current approach of searching for peaks in the V(k,f) representation. We tested this method on digital phantom data created using finite element models (FEMs) in viscoelastic media excited by a simulated acoustic radiation force push from a curved linear array. We evaluated the algorithm with different levels of added noise. Additionally, we tested the methods on data acquired in viscoelastic phantoms with a Verasonics system. The MUSIC algorithm provided dispersion estimation with lower errors than the conventional peak search strategy. This method can be used for evaluation of wave velocity dispersion in viscoelastic tissues and guided wave propagation. [This work was supported in part by grant R01DK092255.]
An ultrasound surface wave elastography technique for noninvasive measurement of surface lung tissue
Osborn, Thomas G. , Greenleaf, James F. , Kalra, Sanjay , Zhang, Xiaoming , Zhou, Boran , Bartholmai, Brian J.

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3721-3721

10.1121/1.4988149 Get It

Ultrasonography is not widely used in clinic for lung assessment because ultrasound cannot image deep lung tissue. In this abstract, we present a novel technique, lung ultrasound surface wave elastography (LUSWE), for measuring the elastic properties of superficial lung tissue. In LUSWE, a small, local, and 0.1 second harmonic vibration is generated on the chest of a subject. The speed of surface wave on the lung is measured by using an ultrasound probe. We are evaluating LUSWE for assessing patients with interstitial lung disease (ILD). LUSWE may be useful for assessing ILD because most ILD patients have typical fibrotic scars in the peripheral and subpleural regions of the lung. In a large clinical study of ILD patients, we measure both lungs through six intercostal spaces for patients and controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. In an example, the surface wave speed is 1.88 ± 0.11 m/s and 3.3 ± 0.37 m/s, respectively, for a healthy subject and an ILD patient at 100 Hz and in the same intercostal space. LUSWE may compliment the clinical standard high-resolution computed tomography for assessing ILD. LUSWE may be useful for assessing other lung disorders.
Role of diastolic function indices in the risk stratification of patients with mixed aortic valve disease
Egbe, Alexander C. , Khan, Arooj R., Boler, Amber, Said, Sameh M. , Geske, Jeffrey B. , Miranda, William R. , Akintoye, Emmanuel , Connolly, Heidi M. , Warnes, Carole A. , Oh, Jae K. , Geske, Jeffrey B

European Heart Journal - Cardiovascular Imaging | June 10, 2017 | Volume: 19 | Issue: 6 | Pages: 668-674

10.1093/ehjci/jex148 | PMID 28655164 Get It