Citations

Institution: Mayo Clinic Clear

Showing 10 of 108195 citations.

CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Diehn, Felix E. , Michalak, Gregory J. , Kotsenas, Amy L. , Lindell, E. Paul , Halaweish, Ahmed F., DeLone, David R. , Campeau, Norbert G , Halaweish, Ahmed F , Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G. , Diehn, Felix E

Acta Radiologica Open | November 27, 2017 | Volume: 6 | Issue: 11 | Pages: 205846011774327

10.1177/2058460117743279 | PMID 29225924 Get It

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Can time to failure predict the faulty component in artificial urinary sphincter device malfunctions?
Yang, David Y. , Linder, Brian J. , Miller, Adam R. , Rangel, Laureano J. , Elliott, Daniel S. , Yang Md, David , Linder, Brian J

International Journal of Urology | November 26, 2017 | Volume: 25 | Issue: 2 | Pages: 146-150

10.1111/iju.13485 | PMID 29178540 Get It

ObjectiveArtificial urinary sphincter malfunctions can occur in any of the individual components. Preoperative identification of the malfunctioning component can be valuable for patient counseling and surgical planning. The optimal strategy for repair of failed artificial urinary sphincter components is debated given the relative rarity of the situation. The aim of the present study was to evaluate the relationship of time to failure with failed artificial urinary sphincter component and to compare our outcomes of specific component versus complete device replacement.MethodsFrom 1983 to 2011, 1805 artificial urinary sphincter procedures were carried out at Mayo Clinic (Rochester, Minnesota, USA), of which 1072 patients underwent primary artificial urinary sphincter placement. Clinical variables, including time to failure, were evaluated for association with component failure. Bootstrap analysis was used to estimate the differences in time to reach a fixed percentage of component failure.ResultsA total of 115 patients experienced device failure at a median follow up of 4.2 years. Urethral cuff, abdominal reservoir, scrotal pump and tubing malfunction occurred in 53 (4.9%), 26 (2.4%), 11 (1%) and 25 (2.3%) patients, respectively. Increasing age at the time of primary surgery was protective of cuff malfunction (hazard ratio 0.97, P = 0.04). Time to 3% urethral cuff failure outpaced other component failures (P < 0.05). Secondary failure‐free rates after whole device versus specific component revisions were comparable (P = 0.38).ConclusionsClinical predictors for artificial urinary sphincter failure continue to be difficult to establish. Although single component versus entire device replacement have similar outcomes, if pursuing single component revision, we recommend cuff‐first interrogation in devices in place for >3 years, as this represents the most likely component to fail.
A Mysterious DRESS Case: Autoimmune Enteropathy Associated with DRESS Syndrome
Adike, Abimbola , Boppana, Vaishnavi, Lam‐Himlin, Dora , Stanton, Melissa, Nelson, Steven B., Ruff, Kevin C. , Nelson, Steven

Case Reports in Gastrointestinal Medicine | November 26, 2017 | Volume: 2017 | Issue: No issue available | Pages: 1-5

10.1155/2017/7861857 | PMID 29333302 Get It

Drug Reaction with Eosinophilia and Systemic Symptoms (DRESS) is a rare but potentially life-threatening cutaneous hypersensitivity reaction characterized by extensive mucocutaneous eruption, fever, hematologic abnormalities, and extensive organ involvement. Here, we present a case of a young woman with DRESS syndrome following exposure to vancomycin with renal, cutaneous, and gastrointestinal involvement. To the best of our knowledge, this is the first case description in the literature of DRESS of the gastrointestinal tract with autoimmune enteropathy.
Three‐dimensional virtual cystoscopy: Noninvasive approach for the assessment of urinary tract in fetuses with lower urinary tract obstruction
Werner, Heron , Ribeiro, Gerson , Jesús, Nilson Ramires de , Santos, Gildásio Rocha, Alexandria, Helenara Abadia Ferreira, Júnior, Edward Araujo , Ruano, Rodrigo , Araujo Júnior, Edward , Lopes, Jorge

Prenatal Diagnosis | November 25, 2017 | Volume: 37 | Issue: 13 | Pages: 1350-1352

10.1002/pd.5188 | PMID 29178428 Get It

What is already known about this topic? Lower urinary tract obstruction is associated with high morbidity and mortality. Fetal cystoscopy may allow the correct identification of the etiology of the obstruction and may provide the adequate treatment. What does this study add? Three‐dimensional virtual navigation is a noninvasive approach that provides an immersive virtual reality in the assessment of fetal structures. Three‐dimensional virtual cystoscopy provides a noninvasive evaluation of fetal lower urinary tract obstruction that in the future may help in the selection of candidates for fetal cystoscopy.
Educational and practice gaps in the management of volar melanocytic lesions
Costello, Collin M. , Ghanavatian, Shirin, Temkit, M’hamed , Buras, Matthew , DiCaudo, David J. , Swanson, David C. , Mangold, Aaron R. , Mangold, A R , Buras, Matthew R , Costello, Collin M

Journal of the European Academy of Dermatology and Venereology | November 25, 2017 | Volume: 32 | Issue: 9 | Pages: 1450-1455

10.1111/jdv.14712 | PMID 29178552 Get It

AbstractBackgroundThe benign and malignant patterns of acral melanocytic naevi (AMN) and acral melanomas (AM) have been defined in a series of retrospective studies. A three‐step algorithm was developed to determine when to biopsy acral melanocytic lesions. This algorithm has only been applied to a Japanese population.ObjectivesOur study aimed to review the current management strategy of acral melanocytic lesions and to investigate the utility of the three‐step algorithm in a predominately Caucasian cohort.MethodsA retrospective search of the pathology and image databases at Mayo Clinic was performed between the years 2006 and 2016. Only cases located on a volar surface with dermoscopic images were included. Two dermatologists reviewed all dermoscopic images and assigned a global dermoscopic pattern. Clinical and follow‐up data were gathered by chart review. All lesions with known diameter and pathological diagnosis were used for the three‐step algorithm.ResultsRegular fibrillar and ridge patterns were more likely to be biopsied (P = 0.01). The majority of AMN (58.1%) and AM (60%) biopsied were due to physician‐deemed concerning dermoscopic patterns. 39.2% of these cases were parallel furrow, lattice‐like or regular fibrillar. When patients were asked to follow‐up within a 3‐ to 6‐month period, only 16.7% of the patients returned within that interval. The three‐step algorithm would have correctly identified four of five AM for biopsy, missing a 6 mm, multicomponent, invasive melanoma.ConclusionWe found one major educational gap in the recognition of low‐risk lesions with high rates of biopsy of the fibrillary pattern. Recognizing low‐risk dermoscopic patterns could reduce the rate of biopsy of AMN by 23.3%. We identified two major practice gaps, poor patient compliance with follow‐up and the potential insensitivity of the three‐step algorithm to small multicomponent acral melanocytic lesions.
Faculty Opinions recommendation of Deficiency of tumor suppressor NDRG2 leads to attention deficit and hyperactive behavior.
Wu, Long‐Jun , Eyo, Ukpong B

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | November 24, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.732025554.793539172 Get It

Letter to the Editor. Computed tomography angiography in brain death determination: is there justification for its use?
Greer, David M. , Wijdicks, Eelco F. M. , Kaufmann, Timothy J.

Journal of Neurosurgery | November 24, 2017 | Volume: 128 | Issue: 2 | Pages: 650-653

10.3171/2017.4.jns17824 | PMID 29171806 Get It

Longitudinal trajectories of subjective care stressors: the role of personal, dyadic, and family resources
Bangerter, Lauren R. , Liu, Yin , Zarit, Steven Howard

Aging & Mental Health | November 24, 2017 | Volume: 23 | Issue: 2 | Pages: 255-262

10.1080/13607863.2017.1402292 | PMID 29171960 Get It

Comparison of left atrial pressure monitoring with dedicated catheter versus steerable guiding catheter during transcatheter mitral valve repair
Eleid, Mackram F. , Reeder, Guy S., Rihal, Charanjit S. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | November 24, 2017 | Volume: 92 | Issue: 2 | Pages: 374-378

10.1002/ccd.27430 | PMID 29171684 Get It

AbstractObjectiveThe objective of this study was to determine the accuracy of left atrial pressure (LAP) measurement through the manufacturer provided steerable guiding catheter (SGC) during transcatheter mitral valve repair (TMVR).BackgroundLAP measurement during TMVR has been shown to be associated with clinical improvement when measured through a dedicated catheter.MethodsSimultaneous LAP was performed in consecutive patients using an independent fluid‐filled 4F multipurpose catheter and compared to LAP waveforms measured through the manufacturer‐provided MitraClip SGC during TMVR (Abbott, Santa Clara, CA).ResultsMean age of 10 consecutive subjects with primary mitral regurgitation undergoing TMVR was 83 ± 3 years (60% female). Left atrial v wave and mean pressures through the dedicated catheter were 42 ± 7 and 24 ± 3 mmHg vs. 35 ± 7 and 23 ± 3 mmHg through the SGC (P < 0.001 and P = 0.23, respectively). Mean differences in v wave and mean LAP were 8 ± 4 and 1.0 ± 2.4 mmHg (percent difference 19 and 3%), respectively. SGC waveform overdamping was observed in all cases.ConclusionsLeft atrial v wave pressure measurement through a dedicated catheter with sideholes during TMVR has superior accuracy compared to the manufacturer provided SGC, which results in waveform overdamping and a significant underestimation of v wave pressure. These data have important implications for clinical practice.
Calibrated Peer Review for Interpreting Linear Regression Parameters: Results from a Graduate Course
Enders, Felicity B., Jenkins, Sarah M. , Hoverman, Verna, Enders, Felicity B., Hoverman, Verna R.

Journal of Statistics Education | November 24, 2017 | Volume: 18 | Issue: 2 | Pages: 50

10.1080/10691898.2010.11889489 Get It