Citations

Institution: Mayo Clinic Clear

Showing 10 of 108225 citations.

Alternative methods for virtual heart transplant—Size matching for pediatric heart transplantation with and without donor medical images available
Plasencia, Jonathan D. , Kamarianakis, Yiannis , Karamlou, Tara , Park, Susan S., Nigro, John J. , Frakes, David , Pophal, Stephen , Lagerstrom, Carl F., Velez, Daniel A. , Zangwill, Steven , Ryan, Justin

Pediatric Transplantation | September 24, 2018 | Volume: 22 | Issue: 8 | Pages: No page available

10.1111/petr.13290 | PMID 30251298 Get It

Abstract Background Listed pediatric heart transplant patients have the highest solid‐organ waitlist mortality rate. The donor‐recipient body weight ( DRBW ) ratio is the clinical standard for allograft size matching but may unnecessarily limit a patient's donor pool. To overcome DRBW ratio limitations, two methods of performing virtual heart transplant fit assessments were developed that account for patient‐specific nuances. Method 1 uses an allograft total cardiac volume ( TCV ) prediction model informed by patient data wherein a matched allograft 3‐D reconstruction is selected from a virtual library for assessment. Method 2 uses donor images for a direct virtual transplant assessment. Methods Assessments were performed in medical image reconstruction software. The allograft model was developed using allometric/isometric scaling assumptions and cross‐validation. Results The final predictive model included gender, height, and weight. The 25th‐, 50th‐, and 75th‐percentiles for TCV percentage errors were −13% (over‐prediction), −1%, and 8% (under‐prediction), respectively. Two examples illustrating the potential of virtual assessments are presented. Conclusion Transplant centers can apply these methods to perform their virtual assessments using existing technology. These techniques have potential to improve organ allocation. With additional experience and refinement, virtual transplants may become standard of care for determining suitability of donor organ size for an identified recipient.
Introduction of Microwave Ablation Into a Renal Ablation Practice: Valuable Lessons Learned
Schmitz, John J. , Thompson, R. Houston, Weisbrod, Adam J. , Welch, Brian T. , Hannon, James D. , Schmit, Grant D. , Atwell, Thomas D. , Viers, Boyd R. , Kurup, A Nick, Thompson, Scott M. , Kurup, A. Nicholas

American Journal of Roentgenology | September 24, 2018 | Volume: 211 | Issue: 6 | Pages: 1381-1389

10.2214/ajr.18.19775 | PMID 30247980 Get It

Endovascular Stroke Therapy in the Late Time Window
Schellinger, Peter D. , Demaerschalk, Bart M.

Stroke | September 24, 2018 | Volume: 49 | Issue: 10 | Pages: 2559-2561

10.1161/strokeaha.118.021003 | PMID 30355126 Get It

Absent and Discordant Electronic Health Record Documentation of Complementary and Alternative Medicine in Cancer Care
Wahner‐Roedler, Dietlind L. , Yost, Kathleen J. , O’Byrne, Thomas J., Leppin, Aaron L. , Tilburt, Jon C. , Stan, Daniela L., Wahner-Roedler, Dietlind L., O'Byrne, Thomas Jamie, Branda, Megan E. , Stan, Daniela

The Journal of Alternative and Complementary Medicine | September 24, 2018 | Volume: 24 | Issue: 9-10 | Pages: 988-995

10.1089/acm.2018.0141 | PMID 30247970 Get It

Closing the Brief Case: A 10-Year-Old Girl with Meningoencephalitis
Madigan, Theresa , Ryan, Conor S. , Theel, Elitza S. , Pritt, Bobbi S. , Palm, Jennifer, Schiffman, Elizabeth , Strain, Anna K., Binnicker, Matthew J. , Pritt, Bobbi S , Huskins, W. Charles

Journal of Clinical Microbiology | September 24, 2018 | Volume: 56 | Issue: 10 | Pages: No page available

10.1128/jcm.00255-18 | PMID 30254111 Get It

The Brief Case: A 10-Year-Old Girl with Meningoencephalitis
Madigan, Theresa , Ryan, Conor S. , Theel, Elitza S. , Pritt, Bobbi S. , Palm, Jennifer, Schiffman, Elizabeth , Strain, Anna K., Binnicker, Matthew J. , Pritt, Bobbi S , Huskins, W. Charles

Journal of Clinical Microbiology | September 24, 2018 | Volume: 56 | Issue: 10 | Pages: No page available

10.1128/jcm.00254-18 | PMID 30254110 Get It

In Situ Functional Monitoring of Aerosol Jet-Printed Electronic Devices Using a Combined Sparse Representation-Based Classification (SRC) Approach
Salary, Roozbeh , Lombardi, Jack P. , Weerawarne, Darshana L. , Tootooni, M. Samie , Poliks, Mark D. , Rao, Prahalada

Volume 1: Additive Manufacturing; Bio and Sustainable Manufacturing | September 24, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/msec2018-6586 Get It

The goal of this work is in situ monitoring of the functional properties of aerosol jet-printed electronic devices. In pursuit of this goal, the objective is to develop a multiple-input, single-output (MISO) machine learning model to estimate the device functional properties in a near real-time fashion as a function of process parameters as well as 2D/3D features of line morphology. The aim is to use the MISO model for in situ estimation and thus, monitoring of line/device resistance in aerosol jet printing (AJP) process. To realize this objective, silver nanoparticle structures are printed by varying three process parameters: (i) sheath gas flow rate (ShGFR), (ii) exhaust gas flow rate (EGFR), and (iii) print speed (PS). Subsequently, line morphology is captured in situ using a high-resolution charge-coupled device (CCD) camera, mounted coaxial to the nozzle. Besides, utilizing 2D/3D quantifiers (introduced in the authors’ previous publications), the line morphology is further quantified, and the extracted features (e.g., line width, overspray, cross-sectional area, etc.) are fed as inputs to a novel sparse representation-based classification (SRC) model. The four-point probe method is used for measurement of resistance, and definition of a priori classification labels. The outcome of this research paves the way for future control of device functional properties in AJP process.
Obesity and hemoglobin content impact peak oxygen uptake in human heart failure
Iterson, Erik H. Van , Kim, Chul‐Ho , Uithoven, Katelyn E., Olson, Thomas P. , Uithoven, Katelyn, Van Iterson, Erik H

European Journal of Preventive Cardiology | September 24, 2018 | Volume: 25 | Issue: 18 | Pages: 1937-1946

10.1177/2047487318802695 | PMID 30247068 Get It

Background Exercise intolerance, obesity, and low hemoglobin (hemoglobin<13 and <12 g/dl, men/women, respectively) are common features of heart failure. Despite serving as potent contributors to metabolic dysfunction, the impact of obesity and low hemoglobin on exercise intolerance is unknown. This study tested the hypotheses, compared with non-obese (NO) heart failure with normal hemoglobin, (a) counterparts with low hemoglobin and obesity or non-obesity will demonstrate reduced peak exercise oxygen uptake; (b) obese with normal hemoglobin will demonstrate decreased peak exercise oxygen uptake; (c) compared across stratifications, obese with low hemoglobin will demonstrate the sharpest decrement in peak exercise oxygen uptake. Methods Adults with heart failure ( n = 315; left ventricular ejection fraction≤40%; 77% men) (Group 1: normal hemoglobin and non-obese, n = 137; Group 2: low hemoglobin and non-obese, n = 51; Group 3: normal hemoglobin+obesity, n = 89; Group 4, n = 38: low hemoglobin+obesity; body mass index = 26 ± 3, 26 ± 2, 34 ± 4, 34 ± 4 kg/m 2 , respectively) completed treadmill cardiopulmonary exercise testing as part of routine clinical management. Peak exercise oxygen uptake was measured via standard metabolic system. Results There were no group-wise differences for heart failure class, gender, left ventricular ejection fraction, and resting cardiopulmonary function. Group 1 demonstrated increased peak exercise oxygen uptake versus Groups 2–4 (20 ± 6 versus 17 ± 6, 17 ± 5, 13 ± 4 ml/kg/min, respectively; all p < 0.001); whereas Group 4 peak exercise oxygen uptake was reduced versus all groups ( p < 0.001). Additionally, both body mass index (R 2 = 0.10) and hemoglobin (R 2 = 0.12) were significant predictors of peak exercise oxygen uptake in Group 1; which were relationships not mirrored for Groups 2–4. Conclusion These data suggest obesity together with low hemoglobin are potent contributors to impaired peak exercise oxygen uptake and, hence, oxidative metabolic capacity. In diverse populations of heart failure where obesity and/or low hemoglobin are present, it is important to consider these features together when interpreting peak exercise oxygen uptake and underlying exercise limitations.
Obstructive sleep apnea in refractory epilepsy: A pilot study investigating frequency, clinical features, and association with risk of sudden unexpected death in epilepsy
McCarter, Allison R., Timm, Paul, Shepard, Paul W., Sandness, David J., Luu, Thao, McCarter, Stuart J. , Dueffert, Lucas G., Dresow, Max, Feemster, John, Cascino, Gregory D. , So, Elson L., Sherif, Akil Adrian , Jaliparthy, Keerthi , Chahal, C. Anwar A. , Louis, Erik K. St. , Timm, Paul C, Dueffert, Lucas, Feemster, John C, Sherif, Akil , Chahal, Anwar A, St Louis, E K , Chahal, Choudhary Anwar A , Worrell, Gregory A. , Britton, Jeffrey W. , Somers, Virend K. , McCarter, Stuart J

Epilepsia | September 24, 2018 | Volume: 59 | Issue: 10 | Pages: 1973-1981

10.1111/epi.14548 | PMID 30246243 Get It

SummaryObjectiveWe aimed to determine the frequency of probable obstructive sleep apnea (pOSA) in refractory epilepsy monitoring unit inpatients and clinical features associated with pOSA, including risk for sudden unexpected death in epilepsy (SUDEP).MethodsWe prospectively recruited 49 consecutive adult patients admitted to the Mayo Clinic Epilepsy Monitoring Unit with focal, generalized, or unclassified epilepsy syndromes. pOSA was identified using oximetric oxyhemoglobin desaturation index (ODI) and the Sleep Apnea–Sleep Disorders Questionnaire (SA‐SDQ) and STOP‐BAG screening tools. Revised SUDEP Risk Inventory (rSUDEP‐7) scores were calculated, and epilepsy patients with and without pOSA were compared with Wilcoxon signed‐rank tests. Correlation and regression analyses were utilized to determine relationships between pOSA and rSUDEP‐7 scores.ResultsThirty‐five percent of patients had pOSA, with a mean ODI of 11.3 ± 5.1/h (range = 5.1‐22.8). Patients with pOSA were older and heavier, and more frequently had a focal epilepsy syndrome and longer epilepsy duration, with higher SA‐SDQ and STOP‐BAG scores (all P < 0.05). Median rSUDEP‐7 score was 3 ± 1.4 (range = 0‐6). Higher rSUDEP‐7 scores were positively correlated with higher ODI (P = 0.036). rSUDEP‐7 score ≥ 5 was associated with pOSA by ODI, SA‐SDQ, and STOP‐BAG questionnaire criteria (P < 0.05).SignificanceOur pilot study identified a high frequency of pOSA in refractory epilepsy monitoring patients, finding that pOSA patients were older and heavier, with higher screening symptoms for sleep apnea and more frequent focal seizures with a longer epilepsy duration. We also found a possible association between OSA and SUDEP risk. Identification and treatment of OSA in patients with epilepsy could conceivably provide a novel approach toward preventing the risk of SUDEP. Future studies with polysomnography are needed to confirm predictive features for OSA in epilepsy populations, and to determine whether OSA is associated with SUDEP risk.
Growing the phenotype of chronic lymphocytic inflammation with pontine perivascular enhancement responsive to steroids (CLIPPERS) in children
Tobin, W. Oliver , Tobin, W Oliver

Developmental Medicine & Child Neurology | September 24, 2018 | Volume: 61 | Issue: 4 | Pages: 391-392

10.1111/dmcn.14043 | PMID 30246371 Get It

This commentary is on the case series by Sa et al. on pages 490–496 of this issue.