Citations

Institution: Mayo Clinic Clear

Showing 10 of 108229 citations.

The Effects of Resection Technique on Implant Migration in Single Radius Posterior-Stabilized Total Knee Replacement
Teeter, Matthew G. , Perry, Kevin I. , Yuan, Xunhua , Howard, James L. , Perry, Kevin, Lanting, Brent A.

The Journal of Knee Surgery | December 19, 2018 | Volume: 33 | Issue: 01 | Pages: 078-083

10.1055/s-0038-1676462 | PMID 30562833 Get It

AbstractThe purpose of the present study was to measure the effects of gap balancing and resection techniques on migration of a single total knee replacement implant design. A total of 23 patients (24 knees) were recruited on referral to either a surgeon performing gap balancing or a surgeon performing measured resection and followed prospectively. All patients received a fixed bearing, posterior stabilized total knee replacement implant of a single radius femoral component design with cement fixation, and all aspects of care outside of resection technique were identical. Patients underwent radiostereometric analysis (RSA) at 2 weeks (baseline), 6 weeks, 3 months, 6 months, 1 year, and 2 years. Migration of the tibial and femoral components was compared between groups. Tibial component migration was greater at 2 years in the gap balancing group (mean difference = 0.336 mm, p = 0.036), but there was no difference at 1 year. One measured resection and three gap balancing tibial components demonstrated continuous migration > 0.2 mm between years 1 and 2. There was no difference in femoral component migration. Small differences in tibial component migration were found between the gap balancing and measured resection techniques. However, comparing the migration to established predictive thresholds for long-term loosening risk, implants performed with both techniques were found to have equally low revision risk.
Safety and efficacy of combined ruxolitinib and decitabine in accelerated and blast-phase myeloproliferative neoplasms
Rampal, Raajit K. , Price, Leah , Berenzon, Dmitriy, Abboud, Camille N. , Kremyanskaya, Marina , Weinberg, Rona Singer , Salama, Mohamed E. , Menghrajani, Kamal , Najfeld, Vesna , Sandy, Lonette, Heaney, Mark , Levine, Ross L. , Dueck, Amylou C. , Goldberg, Judith D. , Dueck, A. C. , Price, Leah , Goldberg, Judith D , Najfeld, Vesna , Mascarenhas, John , Kosiorek, Heidi , Hexner, Elizabeth O. , Mesa, Ruben A. , Hoffman, Ronald

Blood Advances | December 18, 2018 | Volume: 2 | Issue: 24 | Pages: 3572-3580

10.1182/bloodadvances.2018019661 | PMID 30563881 Get It

Abstract Myeloproliferative neoplasms (MPN), including polycythemia vera, essential thrombocythemia, and primary myelofibrosis, have a propensity to evolve into accelerated and blast-phase disease (MPN-AP/BP), carrying a dismal prognosis. Conventional antileukemia therapy has limited efficacy in this setting. Thus, MPN-AP/BP is an urgent unmet clinical need. Modest responses to hypomethylating agents and single-agent ruxolitinib have been reported. More recently, combination of ruxolitinib and decitabine has demonstrated synergistic in vitro activity in human and murine systems. These observations led us to conduct a phase 1 study to explore the safety of combined decitabine and dose-escalated ruxolitinib in patients with MPN-AP/BP. A total of 21 patients were accrued to this multicenter study. Ruxolitinib was administered at doses of 10, 15, 25, or 50 mg twice daily in combination with decitabine (20 mg/m2 per day for 5 days) in 28-day cycles. The maximum tolerated dose was not reached. The most common reasons for study discontinuation were toxicity/adverse events (37%) and disease progression (21%). Fourteen patients died during study treatment period or follow-up. The median overall survival for patients on study was 7.9 months (95% confidence interval, 4.1-not reached). Among evaluable patients, the overall response rate by protocol-defined criteria (complete remission with incomplete count recovery + partial remission) was 9/17 (53%) and by intention-to-treat analysis was 9/21 (42.9%). The combination of decitabine and ruxolitinib was generally well tolerated by patients with MPN-AP/BP and demonstrates potentially promising clinical activity. A phase 2 trial evaluating the efficacy of this combination regimen is ongoing within the Myeloproliferative Disorder Research Consortium.
1016: USEFULNESS OF POINT-OF-CARE ULTRASOUND FOR CHARACTERIZATION OF PRE-LIVER TRANSPLANT PLEURAL EFFUSION
Kwon, Minkyung , Prada, Gabriel , Marenco, Lina, Canabal, Juan, Keaveny, Andrew P. , Pai, Sher‐Lu , Díaz‐Gómez, José L.

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 486-486

10.1097/01.ccm.0000551764.90373.73 Get It

1596: CEREBRAL MALARIA: AN ATOVAQUONE A DAY KEEPS THE DOCTOR AWAY
Kinsman, Kristiann, Myers, Melissa A , Park, John, Wijdicks, Eelco F. M.

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 773-773

10.1097/01.ccm.0000552338.61360.bb Get It

1558: PREDICTORS OF DYSRHYTHMIAS WITH NOREPINEPHRINE USE IN SEPTIC SHOCK PATIENTS
Davidson, K. Erin, Jones, Gary M., Samarin, Michael, Kimmons, Lauren A. , Jones, G. Morgan

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 755-755

10.1097/01.ccm.0000552301.47899.e2 Get It

642: SUCCESSFULLY TREATED MUCORMYCOSIS WITH INTRAPLEURAL AMPHOTERICIN B AND PNEUMONECTOMY
Kwon, Minkyung , Arunthari, Vichaya, Canabal, Juan, Mendez, Julio, Makey, Ian A., Thomas, Mathew

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 301-301

10.1097/01.ccm.0000551394.22198.31 Get It

1166: NIVOLUMAB-INDUCED PNEUMONITIS LEADING TO RESPIRATORY FAILURE
Kwon, Minkyung , Arunthari, Vichaya, Patel, Neal M. , Lee, Augustine S. , Tan, Winston , Young, Paul , Rojas, Carlos A. , Colaco, Brendon

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 560-560

10.1097/01.ccm.0000551911.05745.17 Get It

1161: TIMELINESS OF CORTICOSTEROID USE IN ICU PATIENTS WITH PNEUMONIA AND ARDS
Odeyemi, Yewande , Wieruszewski, Patrick M. , Yadav, Hemang , Wieruszewski, Patrick M , Herasevich, Svetlana , Gajic, Ognjen

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 557-557

10.1097/01.ccm.0000551906.96335.48 Get It

“Migratory” Pattern of Corticosteroid-Related Multifocal Bone Infarction on Bone Scintigraphy
Roarke, Michael A., Yang, Ming , Roarke, Michael C., Nguyen, Ba D.

Clinical Nuclear Medicine | December 18, 2018 | Volume: 44 | Issue: 2 | Pages: 155-156

10.1097/rlu.0000000000002403 | PMID 30562189 Get It

Abstract We present serial bone scintigraphy examinations in a 38-year-old woman who presented with posterior left rib pain in the setting of adrenal insufficiency secondary to pituitary damage as a result of radiation treatment for orbital sarcoma.
Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Zhou, Wei , Bartlett, David J. , Glazebrook, Katrina N. , Carter, Rickey E. , Zhou, Wei , Carter, Rickey E , Diehn, Felix E. , Kotsenas, Amy L. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Investigative Radiology | December 18, 2018 | Volume: 54 | Issue: 4 | Pages: 204-211

10.1097/rli.0000000000000535 | PMID 30562270 Get It

Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.