Citations

Institution: Mayo Clinic Clear

Showing 10 of 108231 citations.

Peri-Myocardial Infarction Pericarditis: Current Concepts
Michael, Gharacholou S, Bryan, Vaca-Cartagena F, Pragnesh, Parikh P, Peter, Pollak M, Charles, Bruce, Vaca‐Cartagena, Bryan F. , Bryan, Vaca-Cartagena F

Clinical Cardiology and Cardiovascular Medicine | August 9, 2019 | Volume: No volume available | Issue: No issue available | Pages: 23-26

10.33805/2639.6807.121 Get It

Peri-Myocardial Infarction Pericarditis (PMIP), or epistenocardiac pericarditis, has been considered a relatively benign condition occurring within a few days after Myocardial Infarction (MI). Although the condition usually does not require specific treatment, the finding of a pericardial friction rub in the post-MI patient does prompt a careful review of post-MI symptoms and test results, including dysrhythmia recordings, Electro-Cardio Grams (EKG), and the Transthoracic Echocardiogram (TTE) to exclude potentially life threatening post-MI mechanical complications such as free wall rupture. The auscultatory findings of a pericardial rub often represent a teaching opportunity for house staff and students, yet given the self-limited course of PMIP, very little is known regarding the mechanism, biology, imaging findings, and management strategy in patients with and without symptoms. We review the current understanding of PMIP for clinicians caring for post-MI patients.
‘RED’ groups: a bottom‐up approach to wellness
Nordhues, Hannah C. , Kashiwagi, Deanne T. , Kubey, Alan , Kubey, Alan A , Haddox, Candace L.

The Clinical Teacher | August 8, 2019 | Volume: 16 | Issue: 4 | Pages: 420-422

10.1111/tct.13076 | PMID 31397100 Get It

Recruiting the Next Generation of Surgeon-Scientists in Plastic and Reconstructive Surgery: The Value of Research Fellowships
DeCoster, Ryan , Rinker, Brian, Vásconez, Henry C., Rinker, Brian D

Plastic & Reconstructive Surgery | August 8, 2019 | Volume: 144 | Issue: 5 | Pages: 944e-945e

10.1097/prs.0000000000006136 | PMID 31403567 Get It

Integration of high velocity test object motion into a channelized Hotelling observer for the assessment of x-ray angiography systems
Tao, Ashley , Fetterly, Kenneth A. , Fetterly, Kenneth

Physics in Medicine & Biology | August 8, 2019 | Volume: 64 | Issue: 18 | Pages: 185011

10.1088/1361-6560/ab39c4 | PMID 31394507 Get It

Abstract Assessment of x-ray angiography system performance is typically performed using stationary test objects with simple geometries such as a disk on a uniform background. However, these methods do not represent realistic imaging conditions in interventional cardiology as anatomy and devices are inherently non-stationary due to cardiac motion. In this work, a novel implementation of the channelized Hotelling observer (CHO) was used to assess the influence of motion blur on object detectability. A standard CHO model assumes imaging system stationarity whereby the detectability index of a test object is independent of location. However, real angiography systems are inherently non-stationary. While vendor correction gain factors and offset maps are used to compensate for visual non-uniformities, these corrections do not restore stationarity to the images. Methods to accommodate non-stationarity and allow assessment of the influence of motion blur on test object detectability will be presented. The effect of motion blur was quantified with the relative detectability index ( ), where the for an object when moving with constant linear velocity was compared to a low velocity ‘pseudo-stationary’ condition to account for system non-stationarity. The pseudo-stationary condition was used to isolate the influences of spatial non-stationarity and motion blur. Three different test object shapes (disks, spheres and capsules) with linear velocity in the range 0–30 cm · s −1 were tested. For 1 mm diameter objects and linear velocity 30 cm · s −1 , was degraded by 37%, 33% and 42% for the disk, sphere and capsule respectively, relative to the pseudo-stationary condition. Considering all test objects with diameter greater than 2 mm and linear velocity 30 cm · s −1 , was degraded by less than 10% due to motion. In summary, this work describes a new approach to assess performance of x-ray angiography systems using the CHO model and moving test objects.
Outcome of endoscopic resection of colonic polyps larger than 10 mm in patients with inflammatory bowel disease
Yadav, Siddhant, Harmsen, William S. , Song, Louis M. Wong Kee , Wong Kee Song, Louis M, Loftus, Edward V. , Coelho–Prabhu, Nayantara

Endoscopy International Open | August 8, 2019 | Volume: 07 | Issue: 08 | Pages: E994-E1001

10.1055/a-0953-2021 | PMID 31404424 Get It

Abstract Background and study aims There are limited published data on endoscopic removal of colorectal polyps by endoscopic mucosal resection (EMR) and endoscopic mucosal dissection (ESD) in patients with inflammatory bowel disease (IBD). Patients and methods We performed a retrospective review of patients with colonic IBD and colonic polyps >10mm who underwent EMR and/or ESD at our institution between January 1, 2012 and June 31, 2016. Results Ninety-seven patients with pathology-confirmed IBD (median disease duration 16 years) were included. Mild or moderate active colitis (in background biopsies) was seen in 85 %. Of the total 124 polyps, location was ascending colon in 44 %, transverse in 15 % and sigmoid in 18.5 %; of the total, 55 % were < 20 mm and 45 % were ≥20mm in maximal diameter. Using the Paris classification, 56 % of polyps were polypoid sessile (Is) polyps, while 38 % were non-polypoid (IIa, IIb, IIc). EMR was used in 118 polyps, three required ESD, and three by combined EMR-ESD. Seventy-two percent were resected en-bloc; 28 % underwent piecemeal resection. Histology included low-grade dysplasia in 75, serrated adenoma in 31, and tubular adenoma in 14 polyps. Chromoendoscopy was used in 33 (26.6 %). Adverse events occurred in three patients. Colectomy was performed in 11 patients within 12 months. Recurrence was seen in 20 polyps, 11 of which were successfully resected en-bloc using EMR. Polyps ≥ 20 mm and polyps treated with APC were found to have a statistically significantly higher risk of recurrence. Conclusion This study demonstrates the efficacy and safety of endoscopic resection of large polyps in patients with IBD, making them effective alternatives to colectomy.
Complete Surgical Metastasectomy of Renal Cell Carcinoma in the Post-Cytokine Era
Lyon, Timothy D. , Thompson, R. Houston, Shah, Paras , Lohse, Christine M. , Boorjian, Stephen A. , Costello, Brian A. , Cheville, John C. , Leibovich, Bradley C. , Lyon, Timothy D

Journal of Urology | August 8, 2019 | Volume: 203 | Issue: 2 | Pages: 275-282

10.1097/ju.0000000000000488 | PMID 31393812 Get It

The Clinical Use of Cricoid Pressure: First, Do No Harm
Rice, Mark J., Brull, Sorin J. , Zdravković, Marko , Brull, Sorin J

Anesthesia & Analgesia | August 8, 2019 | Volume: 132 | Issue: 1 | Pages: 261-267

10.1213/ane.0000000000004360 | PMID 31397697 Get It

Application of cricoid pressure (CP) during rapid sequence induction and intubation sequence has been a “standard” of care for many decades, despite limited scientific proof of its efficacy in preventing pulmonary aspiration of gastric contents. While some of the current rapid sequence induction and intubation guidelines recommend its use, other international guidelines do not, and many clinicians argue that there is insufficient evidence to either continue or abandon its use. Recently published articles and accompanying editorials have reignited the debate on the efficacy and safety of CP application and have generated multiple responses that pointed out the various (and significant) limitations of the available evidence. Thus, a critical discussion of available data must be undertaken before making a final clinical decision on such an important patient safety issue. In this review, the authors will take an objective look at the available scientific evidence about the effectiveness and safety of CP in patients at risk of pulmonary aspiration of gastric contents. We suggest that current data are inadequate to impose clinical guidelines on the use of CP because we acknowledge that currently there is not, and there may never be, a method to prevent aspiration in all patients. In addition, we reiterate that a universally accepted medical-legal standard for approaching the high-risk aspiration patient does not exist, discuss the differences in practice between the US and international practitioners regarding use of CP, and propose 5 recommendations on how future studies might be designed to obtain optimal scientific evidence about the effectiveness and safety of CP in patients at risk for pulmonary aspiration.
ALG9 Mutation Carriers Develop Kidney and Liver Cysts
Besse, Whitney , Chang, Alex R. , Luo, Jonathan Z. , Triffo, William , Moore, Bryn S. , Gulati, Ashima , Hartzel, Dustin N. , Mane, Shrikant , Torres, Vicente E. , Somlo, Stefan , Torres, Vicente E , Chang, Alexander R , Mirshahi, Tooraj

Journal of the American Society of Nephrology | August 8, 2019 | Volume: 30 | Issue: 11 | Pages: 2091-2102

10.1681/asn.2019030298 | PMID 31395617 Get It

Significance Statement Dominantly inherited polycystic kidney and liver phenotypes occur when epithelial cells in these organs have reduction of polycystin-1 functional dosage. In a cohort of genetically unresolved polycystic liver and kidney disease, the authors identified heterozygous loss of function mutations in ALG9 . ALG9 encodes an endoplasmic reticulum enzyme that builds N -glycans, and the authors show that Alg9 inactivation results in impaired polycystin-1 maturation. Using a novel ‘genotype-first’ approach to ascertain individuals based strictly on their ALG9 genotype from a large cohort of exome-sequenced individuals, the authors find that 7/8 (88%) of ALG9 mutation carriers over age 50 have multiple kidney cysts. Together, these findings identify ALG9 as a novel human polycystic kidney and liver disease gene and support the utility of a genotype-driven approach to candidate disease gene validation and genotype-phenotype correlation. Background Mutations in PKD1 or PKD2 cause typical autosomal dominant polycystic kidney disease (ADPKD), the most common monogenic kidney disease. Dominantly inherited polycystic kidney and liver diseases on the ADPKD spectrum are also caused by mutations in at least six other genes required for protein biogenesis in the endoplasmic reticulum, the loss of which results in defective production of the PKD1 gene product, the membrane protein polycystin-1 (PC1). Methods We used whole-exome sequencing in a cohort of 122 patients with genetically unresolved clinical diagnosis of ADPKD or polycystic liver disease to identify a candidate gene, ALG9 , and in vitro cell-based assays of PC1 protein maturation to functionally validate it. For further validation, we identified carriers of ALG9 loss-of-function mutations and noncarrier matched controls in a large exome-sequenced population-based cohort and evaluated the occurrence of polycystic phenotypes in both groups. Results Two patients in the clinically defined cohort had rare loss-of-function variants in ALG9 , which encodes a protein required for addition of specific mannose molecules to the assembling N-glycan precursors in the endoplasmic reticulum lumen. In vitro assays showed that inactivation of Alg9 results in impaired maturation and defective glycosylation of PC1. Seven of the eight (88%) cases selected from the population-based cohort based on ALG9 mutation carrier state who had abdominal imaging after age 50; seven (88%) had at least four kidney cysts, compared with none in matched controls without ALG9 mutations. Conclusions ALG9 is a novel disease gene in the genetically heterogeneous ADPKD spectrum. This study supports the utility of phenotype characterization in genetically-defined cohorts to validate novel disease genes, and provide much-needed genotype-phenotype correlations.
Noninvasive Assessment of Aortic Pulse Wave Velocity by the Brachial Occlusion-Cuff Technique: Comparative Study
Fabián, Vratislav , Matera, Lukáš , Bayerová, Kristýna , Havlík, Jan , Křemen, Václav , Pudil, Jan , Sajgalik, Pavol , Kremen, Vaclav , Zemánek, David

Sensors | August 8, 2019 | Volume: 19 | Issue: 16 | Pages: 3467

10.3390/s19163467 | PMID 31398931 Get It

Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 ± 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 ± 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 ± 1.01) m/s. The correlation between methods using a Pearson’s correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment.
Improving the image quality of 3D FLAIR with a spiral MRI technique
Li, Zhiqiang , Pipe, James G. , Ooi, Melvyn B. , Kuwabara, Michael , Karis, John P.

Magnetic Resonance in Medicine | August 8, 2019 | Volume: 83 | Issue: 1 | Pages: 170-177

10.1002/mrm.27911 | PMID 31393038 Get It

PurposeFluid‐attenuated inversion recovery (FLAIR) nulls the CSF signal and is widely used in neuro MRI exams. A 3D scan can provide high SNR, contiguous coverage, and reduced sensitivity to through‐plane CSF flow. In this work, a 3D spiral FLAIR technique is proposed to improve the image quality of conventional 3D Cartesian FLAIR.MethodsThe 3D spiral FLAIR sequence incorporated a spiral‐in/out readout to preserve higher scan efficiency and eliminate off resonance‐induced artifacts observed with a commonly implemented spiral‐out readout, a compensation approach to minimize phase errors due to the concomitant fields accompanying the spiral gradient, and an adapted variable flip angle scheme to preserve scan efficiency and maintain a long and stable echo train. 3D Cartesian and spiral FLAIR (~6 min each) were acquired on a 3 Tesla scanner from 6 subjects (age range: 31‐64 years; mean: 39.5). Two neuroradiologists rated the images in a blinded fashion on a 5‐point scale. The noise performance was assessed quantitatively.ResultsCompared to 3D Cartesian FLAIR, 3D spiral FLAIR exhibits greater reduction of artifacts from CSF, especially anterior to the brain stem (rated better in 4 cases), artifacts attributed to blood/flow in the deep brain (better or much better in all 6 cases), and superior overall image quality (much better in 5 cases) despite residual susceptibility artifacts near the nasal cavity. Quantitative assessment demonstrates ~1.5× higher average SNR than Cartesian data.Conclusion3D spiral FLAIR achieves higher SNR, reduced CSF, and blood/flow artifacts, providing an alternative to 3D Cartesian FLAIR for neurological exams.