ImportanceSelf-measured blood pressure (SMBP) with commercially available connected smartphone applications may help patients effectively use SMBP measurements.ObjectiveTo determine if enhanced SMBP paired with a connected smartphone application was superior to standard SMBP for blood pressure (BP) reduction or patient satisfaction.Design, Setting, and ParticipantsThis randomized clinical trial was conducted among 23 health systems participating in PCORnet, the National Patient-Centered Clinical Research Network, and included patients who reported having uncontrolled BP at their last clinic visit, a desire to lower their BP, and a smartphone. Enrollment and randomization occurred from August 3, 2019, to December 31, 2020, which was followed by 6 months of follow-up for each patient. Analysis commenced shortly thereafter.InterventionsEligible participants were randomly assigned to enhanced SMBP using a device that paired with a connected smartphone application (enhanced) or a standard device (standard). Participants received their device in the mail, along with web-based educational materials and phone-based support as needed. No clinician engagement was undertaken, and the study provided no special mechanisms for delivering measurements to clinicians for use in BP management.Main Outcomes and MeasuresReduction in systolic BP, defined as the difference between clinic BP at baseline and the most recent clinic BP extracted from electronic health records at 6 months.ResultsEnrolled participants (1051 enhanced [50.0%] vs 1050 standard [50.0%]; 1191 women [56.7%]) were mostly middle-aged or older (mean [SD] age, 58 [13] years), nearly a third were Black or Hispanic (645 [31%]), and most were relatively comfortable using technology (mean [SD], 4.1 [1.1] of 5). The mean (SD) change in systolic BP from baseline to 6 months was −10.8 (18) mm Hg vs −10.6 (18) mm Hg (enhanced vs standard: adjusted difference, −0.19 mm Hg; 95% CI, −1.83 to 1.44;P = .81). Secondary outcomes were mostly null, except for documented attainment of BP control to lower than 140/<90 mm Hg, which occurred in 32% enhanced vs 29% standard groups (odds ratio, 1.15; 95% CI, 1.01-1.34). Most participants were very likely to recommend their SMBP device to a friend (70% vs 69%).Conclusions and RelevanceThis randomized clinical trial found that enhanced SMBP paired with a smartphone application is not superior to standard SMBP for BP reduction or patient satisfaction.Trial RegistrationClinicalTrials.gov Identifier:NCT03796689
Safety and Effectiveness of a Catheter With Contact Force and 6-Hole Irrigation for Ablation of Persistent Atrial Fibrillation in Routine Clinical Practice
Predictive Polygenic Score for Outcome after First-Line Oxaliplatin-Based Chemotherapy in Colorectal Cancer Patients Using Supervised Principal Component Analysis
Abstract Background: Associations between candidate germline genetic variants and treatment outcome of oxaliplatin, a drug commonly used for patients with colorectal cancer, have been reported but not robustly established. This study aimed to construct polygenic hazard scores (PHSs) as predictive markers for oxaliplatin treatment outcome by using a supervised principal component approach (PCA). Methods: Genome-wide association analysis for overall survival, including interaction terms (SNP*treatment type) was carried out using two phase III trials, 3,098 resected stage III colon cancer (rCC) patients of NCCTG N0147 and 506 metastatic colorectal cancer (mCRC) patients of NCCTG N9741, separately. SNPs showing interaction with genome-wide significance (P < 5 × 10–8) were selected for PCA to derive a PHS. PHS interaction with treatment was included in Cox regression models to predict outcome. Replication of prediction models was performed in an independent cohort, DACHS. Results: The two PHSs based on the first two principal components of selected SNPs (15SNPs for rCC and 13SNPs for mCRC) were used to construct interaction terms with treatment type and included in models adjusted for clinical covariables. However, in the DACHS study, the addition of the two PHS terms to clinical models did not improve the prediction error in either patients with rCC or mCRC. PHS interaction was also not replicated. Conclusions: The PHSs derived using principal components efficiently combined multiple predictive SNPs for estimating likelihood of benefit from oxaliplatin versus other treatment but could not be replicated. Impact: These results highlight the potential but also challenges in generating evidence for a predictive polygenic score for oxaliplatin efficacy.
Netrin G1 Is a Novel Target Antigen in Primary Membranous Nephropathy
Background Primary membranous nephropathy (MN) is caused by circulating autoantibodies binding to antigens on the podocyte surface. PLA 2 R1 is the main target antigen in 70%–80% of cases, but the pathogenesis is unresolved in 10%–15% of patients. Methods We used native western blotting to identify IgG4 autoantibodies, which bind an antigen endogenously expressed on podocyte membranes, in the serum of the index patient with MN. These IgG4 autoantibodies were used to immunoprecipitate the target antigen, and mass spectrometry was used to identify Netrin G1 (NTNG1). Using native western blot and ELISA, NTNG1 autoantibodies were analyzed in cohorts of 888 patients with MN or other glomerular diseases. Results NTNG1 was identified as a novel target antigen in MN. It is a membrane protein expressed in healthy podocytes. Immunohistochemistry confirmed granular NTNG1 positivity in subepithelial glomerular immune deposits. In prospective and retrospective MN cohorts, we identified three patients with NTNG1-associated MN who showed IgG4-dominant circulating NTNG1 autoantibodies, enhanced NTNG1 expression in the kidney, and glomerular IgG4 deposits. No NTNG1 autoantibodies were identified in 561 PLA 2 R1 autoantibodies–positive patients, 27 THSD7A autoantibodies–positive patients, and 77 patients with other glomerular diseases. In two patients with available follow-up of 2 and 4 years, both NTNG1 autoantibodies and proteinuria persisted. Conclusions NTNG1 expands the repertoire of target antigens in patients with MN. The clinical role of NTNG1 autoantibodies remains to be defined.
Non‐Vascular Considerations When Interpreting Extremity Arterial and Venous Examinations
Peripheral arterial and venous examinations are performed regularly in vascular labs and interpreted by physicians of different specialities. Many vascular examinations have nonvascular pathology that is either inadvertently imaged by the sonographer or imaged with intent as it relates to patient's symptoms. It is prudent for every reader of vascular studies to be acquainted with the sonographic appearance of these non‐vascular lesions to enable appropriate and optimal interpretation that has a direct bearing on patient's clinical care. Our review includes a discussion of the nonvascular pathologies like lymph nodes, soft tissue edema, soft tissue fluid collections, musculotendinous injuries, soft tissue masses, and joint and bursal pathologies that may be encountered during interpretation of vascular exams. The pictorial essay includes a discussion of their sonographic appearances and pitfalls in interpretation. Multiple illustrative examples and sonographic images of the non‐vascular pathologies found during interpretation of vascular studies have been utilized to highlight their appearances.
AbstractBackgroundDual‐energy CT with virtual noncalcium (VNCa) images allows the evaluation of focal intramedullary bone marrow involvement in patients with multiple myeloma. However, current commercial VNCa techniques suffer from excessive image noise and artifacts due to material decomposition used in synthesizing VNCa images.ObjectivesIn this work, we aim to improve VNCa image quality for the assessment of focal multiple myeloma, using an Artificial intelligence based Generalizable Algorithm for mulTi‐Energy CT (AGATE) method.Materials and methodsAGATE method used a custom dual‐task convolutional neural network (CNN) that concurrently carries out material classification and quantification. The material classification task provided an auxiliary regularization to the material quantification task. CNN parameters were optimized using custom loss functions that involved cross‐entropy, physics‐informed constraints, structural redundancy in spectral and material images, and texture information in spectral images. For training data, CT phantoms (diameters 30 to 45 cm) with tissue‐mimicking inserts were scanned on a third generation dual‐source CT system. Scans were performed at routine dose and half of the routine dose. Small image patches (i.e., 40 × 40 pixels) of tissue‐mimicking inserts with known basis material densities were extracted for training samples. Numerically simulated insert materials with various shapes increased diversity of training samples. Generalizability of AGATE was evaluated using CT images from phantoms and patients. In phantoms, material decomposition accuracy was estimated using mean‐absolute‐percent‐error (MAPE), using physical inserts that were not used during the training. Noise power spectrum (NPS) and modulation transfer function (MTF) were compared across phantom sizes and radiation dose levels. Five patients with multiple myeloma underwent dual‐energy CT, with VNCa images generated using a commercial method and AGATE. Two fellowship‐trained musculoskeletal radiologists reviewed the VNCa images (commercial and AGATE) side‐by‐side using a dual‐monitor display, blinded to VNCa type, rating the image quality for focal multiple myeloma lesion visualization using a 5‐level Likert comparison scale (−2 = worse visualization and diagnostic confidence, −1 = worse visualization but equivalent diagnostic confidence, 0 = equivalent visualization and diagnostic confidence, 1 = improved visualization but equivalent diagnostic confidence, 2 = improved visualization and diagnostic confidence). A post hoc assignment of comparison ratings was performed to rank AGATE images in comparison to commercial ones.ResultsAGATE demonstrated consistent material quantification accuracy across phantom sizes and radiation dose levels, with MAPE ranging from 0.7% to 4.4% across all testing materials. Compared to commercial VNCa images, the AGATE‐synthesized VNCa images yielded considerably lower image noise (50–77% noise reduction) without compromising noise texture or spatial resolution across different phantom sizes and two radiation doses. AGATE VNCa images had markedly reduced area under NPS curves and maintained NPS peak frequency (0.7 lp/cm to 1.0 lp/cm), with similar MTF curves (50% MTF at 3.0 lp/cm). In patients, AGATE demonstrated reduced image noise and artifacts with improved delineation of focal multiple myeloma lesions (all readers comparison scores indicating improved overall diagnostic image quality [scores 1 or 2]).ConclusionsAGATE demonstrated reduced noise and artifacts in VNCa images and ability to improve visualization of bone marrow lesions for assessing multiple myeloma.