Abstract Background We reviewed the scientific literature to gain insight on the epidemiology and outcome of Strongyloides stercoralis infections after transplantation. Methods CINAHL, PUBMED, and OVID/MEDLINE were reviewed from inception through March 31, 2022 using key words Strongyloides and transplantation. Results Our review identified 108 episodes of Strongyloides infection among 91 solid organ transplant (SOT) and 15 hematopoietic cell transplant (HCT) recipients. Median time to infection was 10.8 (range, .14–417) and 8.8 (range, 0–208) weeks after SOT and HCT, respectively. Gastrointestinal symptoms were frequent (86/108 [79.6%]), while skin rash (22/108 [20.3%]) and fever (31/103 [30%]) were less common. Peripheral eosinophilia was observed in half of patients (41/77 [53.2%]). Bacteremia (31/59 [52.5%]) was frequently due to Gram‐negative organisms (24/31 [77.4%]). Abnormal chest radiologic findings were reported in half (56/108 [51.9%]). The majority had hyperinfection syndrome (97/108 [89.8%]) while disseminated strongyloidiasis was less common (11/108 [10.2%]). Thirty‐two cases were categorized as donor‐derived infection (DDI), with donors (23/24 [95.8%]) who had traveled to or lived in endemic areas. Median time to DDI was 8 weeks (range .5–34.3 weeks) after transplantation. Treatment consisted of ivermectin ( n = 26), a benzimidazole ( n = 27), or both drugs ( n = 28). There was high all‐cause mortality (48/107, 44.9%) and a high Strongyloides ‐attributable mortality (32/49, 65.3%). Conclusions Strongyloidiasis should be strongly considered among recipients with epidemiologic risk factors for infection, even in the absence of eosinophilia or rash. A policy that provides guidance on pro‐active screening is needed, to ensure preventive measures are provided to recipients at increased risk.
A fast GPU‐accelerated Monte Carlo engine for calculation of MLC‐collimated electron fields
AbstractBackgroundAlthough intensity‐modulated radiation therapy and volumetric arc therapy have revolutionized photon external beam therapies, the technological advances associated with electron beam therapy have fallen behind. Modern linear accelerators contain technologies that would allow for more advanced forms of electron treatments, such as beam collimation, using the conventional photon multi‐leaf collimator (MLC); however, no commercial solutions exist that calculate dose from such beam delivery modes. Additionally, for clinical adoption to occur, dose calculation times would need to be on par with that of modern dose calculation algorithms.PurposeThis work developed a graphics processing unit (GPU)‐accelerated Monte Carlo (MC) engine incorporating the Varian TrueBeam linac head geometry for a rapid calculation of electron beams collimated using the conventional photon MLC.MethodsA compute unified device architecture framework was created for the following: (1) transport of electrons and photons through the linac head geometry, considering multiple scattering, Bremsstrahlung, Møller, Compton, and pair production interactions; (2) electron and photon propagation through the CT geometry, considering all interactions plus the photoelectric effect; and (3) secondary particle cascades through the linac head and within the CT geometry. The linac head collimating geometry was modeled according to the specifications provided by the vendor, who also provided phase‐space files. The MC was benchmarked against EGSnrc/DOSXYZnrc/GEANT by simulating individual interactions with simple geometries, pencil, and square beam dose calculations in various phantoms. MC‐calculated dose distributions for MLC and jaw‐collimated electron fields were compared to measurements in a water phantom and with radiochromic film.ResultsPencil and square beam dose distributions are in good agreement with DOSXYZnrc. Angular and spatial distributions for multiple scattering and secondary particle production in thin slab geometries are in good agreement with EGSnrc and GEANT. Dose profiles for MLC and jaw‐collimated 6–20‐MeV electron beams showed an average absolute difference of 1.1 and 1.9 mm for the FWHM and 80%–20% penumbra from measured profiles. Percent depth doses showed differences of <5% for as compared to measurement. The computation time on an NVIDIA Tesla V100 card was 2.5 min to achieve a dose uncertainty of <1%, which is ∼300 times faster than published results in a similar geometry using a single‐CPU core.ConclusionsThe GPU‐based MC can quickly calculate dose for electron fields collimated using the conventional photon MLC. The fast calculation times will allow for a rapid calculation of electron fields for mixed photon and electron particle therapy.
Clinical utility of serial serum dilutions for HLA antibody interpretation
Luminex single antigen bead (SAB) testing has increased the sensitivity and specificity of accurately identifying HLA antibodies, in support of all organ transplantation. However, as described in manufacturers' recommendation, the output of the assay, using mean fluorescence intensity (MFI) units, is only semi‐quantitative. Therefore, the ability to use MFI values to compare between different assays, to accurately guide clinical practice, or be used as an endpoint measure in clinical trials, is limited. To improve potential quantification, one must circumvent inherent limitations of SAB assays such as interference and saturation phenomena. In this review, we discuss how measurement of pre‐transplant serum dilutions can be used to determine unacceptable antigens for wait‐listing, determine the likelihood for successful HLA antibody reduction with desensitization, and compare degree of HLA (in)compatibility among various living donors. We also discuss how serum dilutions are optimal for measuring and comparing the efficacy of antibody depletion therapies for desensitization or antibody mediated rejection treatment post‐transplant. Historically, one of the main criticisms for the use of serum dilutions and titer has been the potential labor and cost associated with additional testing. Here, we show how only one or two dilutions can add major value in most circumstances. In summary, the practical use of serum dilutions and titer determination are important methods that can be used before and after transplantation of all organs to quantify antibody accurately and reliably in routine practice and in clinical trials.
Hypertrophic cardiomyopathy with extreme outflow tract obstruction
Co-Registration of pre- and post-Operative images after cochlear Implantation: A proposed technique to Improve cochlear visualization and localization of cochlear electrodes
Background and Purpose After cochlear implantation, metallic artifact can obscure nearby structures on CT images, which is problematic in patients with facial nerve stimulation (FNS). This study evaluated the usefulness of co-registered pre- and post-operative examinations to evaluate the cochlear implant and adjacent structures. Materials and Methods A retrospective review was completed of consecutive patients that underwent CT imaging of the temporal bone before and after placement of a cochlear implant. Two blinded neuroradiologists independently reviewed all available examinations. All examinations were assessed for the presence or absence of dehiscence of the osseous ridge between the cochlea and facial nerve canal (FNC). Pre-operative and fused pre- and post-operative examinations were compared in their ability to visualize the osseous ridge using a 5-point Likert scale (ranging from 1 = unfused images were substantially superior to 5 = fused images were substantially superior). The electrode closest to the FNC were noted. Results Of 34 included patients, 13 (38.2%) were female and 21 (61.8%) were male; average age was 72.2. Seven patients (20.6%) had frank dehiscence between the cochlea and FNC. Fused images were superior to the post-operative study alone for assessing the integrity of the osseous partition between the cochlea and FNC and for reducing artifact from the electrode array (average Likert scores for both reviewers were 4.4 and 4.7). There was good agreement between reviewers in noting electrode closest to the FNC (concordance correlation coefficient=0.82). Conclusions Following cochlear implantation, co-registered pre- and post-operative CT images are superior to conventional images in assessing the anatomic relationship between the cochlea and FNC.
Sit-Stand Desks and Physical Self-care Behaviors in a Family Medicine Residency
Introduction: More than 50% of primary care physicians’ practice involves sedentary desk work. Growing evidence suggests a link between sedentary workplace behaviors and increased morbidity and mortality. Research on the effects of sit-stand desks in the workplace suggests that sit-stand desks reduce sedentary behaviors. This study examined the use and satisfaction of adjustable desks with a height of sit-stand and their association with physical self-care behaviors among family medicine residents. Methods: We conducted a longitudinal cohort survey study at a 9-9-9 family medicine residency after the clinic installed height-adjustable sit-stand desks in January 2020. Standardized questions about the use and satisfaction of adjustable sit-stand desks and physical self-care behaviors were administered in June 2020, December 2020, and December 2021. The survey also included an open text box for feedback. Results: Median time spent standing at the sit-stand desks was 55.0%. The percentage of time standing was similar across June 2020, December 2020, and December 2021. The average satisfaction rate with the desks across all time points was 71.4%. We did not observe significant differences in the proportion of residents’ satisfaction with the adjustable desks over time. Residents who reported standing at the adjustable desk reported increased satisfaction with the desks (Kendall’s τ=.38, P<.001) and with physical self-care behaviors (Kendall’s τ=.25, P<.05). Themes associated with desk dissatisfaction revolved around limited desktop space. Conclusion: Over a nearly 1.5-year period, more than half of family medicine residents reported standing at their adjustable desks and being satisfied with them. Residents who reported standing at adjustable desks also reported increased physical self-care behaviors. Residency programs investing in sit-stand desks may consider options that allow for increased desktop surface space.
Structural Neuroimaging in Adults and Adolescents With Newly Diagnosed Focal Epilepsy