Citations

Institution: Mayo Clinic Clear

Showing 10 of 108195 citations.

Solving the mystery of Reed Sternberg like cells in a composite Peripheral T Cell Lymphoma with Epstein Barr Virus and Epstein Barr Virus driven Lymphoproliferative Disorder
Siddiq, M., Shiwlani, Sheena, Ibrar, Warda, Sonam, Fnu , Hashim, M

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S76-S76

10.1093/ajcp/aqad150.169 Get It

Abstract Introduction/Objective Nodal PTCL with EBV positivity can occasionally contain Reed Sternberg-like cells, and EBV- LPD can mimic Hodgkin lymphoma. Coexistence of these two unusual lymphomas in the same lymph node is very rare. We present a case of a 56-year-old male with Composite EBV+ PTCL NOS and EBV LPD, with positive B-cell gene rearrangement and negative T-cell gene rearrangement presenting a significant diagnostic challenge. Methods/Case Report A 56-year-old male with a history of abdominal tuberculosis presented with lethargy, fatigue, and poor appetite. Physical examination revealed generalized lymphadenopathy. CT scan confirmed lymphadenopathy in bilateral axilla, supraclavicular lymph nodes along with lytic lesions on illiac crest. Ill defined splenic lesions raised concerns for metastasis. Cervical lymph node and bone marrow biopsies were performed. Flow cytometry on the lymph node was not done due to tuberculosis history. Flow cytometry on the bone marrow showed an inverted CD4:CD8 ratio. H&E sections of the lymph node revealed a polymorphic lymphoid infiltrate with prominent Reed Sternberg-like cells. Immunohistochemical staining showed CD30-positive and CD45-negative large cells. T-cell and B-cell gene rearrangements were performed. Initially, B-cell gene rearrangements were positive, while T-gamma was negative. Further testing by IHC and morphological evaluation revealed two distinct cell populations, one with CD3, CD5, and CD7 positivity with partial weak positivity for PD1, CD43, and CD8 and the other consisting of B-cells expressing CD30, EBV, MUM1, and partial expression of BCL6 rare CD79a, and partial weak Pax5. Outside molecular testing showed positive T-cell gene rearrangements. The diagnosis of Composite EBV+ Peripheral T Cell Lymphoma, not otherwise specified, with cytotoxic profile along with EBV driven LPD was made. Bone marrow studies confirmed involvement by the same lymphoma. Results (if a Case Study enter NA) NA Conclusion Identifying EBV-positive Reed Sternberg-like cells in both EBV LPD and PTCL-NOS in a composite lymphoma can be challenging. In the absence of flow cytometry, a composite lymphoma can potentially be misdiagnosed, leading to under-treatment. Repeat testing can be helpful in case of any doubt. Although EBV-positive PTCL with cytotoxic profile and EBV-positive LPD has been reported, the combination of these two lymphomas together is exceedingly rare.
Comparison of FDA-Approved vs. Mayo Clinic’s Ki-67 Immunostaining Protocols for Breast Cancer Specimens: A Quantitative Analysis Using Artificial Intelligence (AI) Based Image Analysis Algorithms
Stoy, Leslie, Rosario, Kristina Del, Lewis, Kyle , Yasir, Saleha, Plagge, Antonius , Chen, Z

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S12-S12

10.1093/ajcp/aqad150.026 Get It

Abstract Introduction/Objective Ki-67, a nuclear protein present during the active phases of the cell cycle, is an important prognostic and predictive marker for many tumor types, including breast cancer. This study compared the results of breast cancer specimens immunohistochemically (IHC) stained with the FDA-approved vs. Mayo Clinic’s (MC) validated Ki-67 protocol using AI-based image analysis algorithms for quantitative examination at an individual cell level. Methods/Case Report Sixty-two breast cancer specimens were selected with a rough equal representation of Ki-67 percentage in low (<10%), intermediate (10-20%) and high (>20%) categories. Two adjacent sections of each specimen were stained with the FDA and MC protocols, respectively, and scanned to obtain whole slide digital images. Two AI algorithms, one with tumor cell identification and the other without, were used to quantify positive and negative cells and calculate Ki-67 percentages. Results (if a Case Study enter NA) Both algorithms show high concordance between the two staining protocols, with r-squared scores of 0.989 and 0.992, respectively, analyzing with or without tumor identification. AI identified tumor better on MC stained slides vs. FDA stained slides. The results demonstrate a high-performance concordance between the MC and the FDA IHC staining protocols. Conclusion The data also illustrates the accuracy of using AI image analysis algorithms to compare different IHC protocols at an individual cell level. The AI tumor identification difference in slides stained with two IHC protocols reflects the importance of training an algorithm with a specific staining protocol to achieve optimal tumor recognition.
Evaluation of Siltuximab and Tocilizumab Analytical Interference on Interleukin 6 Measurements
Kian, Susan Ashrafzadeh, Deters, Rebecca, Irvine, Clayton , Bornhorst, Joshua A. , Bornhorst, Joshua , Wang, Qian , Algeciras‐Schimnich, Alicia

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S123-S124

10.1093/ajcp/aqad150.269 Get It

Abstract Background Interleukin 6 (IL-6) plays important roles in both innate and adaptive immunity, while dysregulated persistent production of IL-6 is involved in pathological development of various diseases associated with inflammation. Targeting the IL-6 pathway has led to many innovative treatment approaches. Siltuximab and Tocilizumab are monoclonal antibodies targeting IL-6 and IL-6 receptors respectively and have been FDA-approved for treatment of Castleman disease (Siltuximab), a rare lymphoproliferative disorder characterized by hyperproduction of IL-6 with an unknown prevalence, autoimmune diseases such as rheumatoid arthritis (Tocilizumab), and both shown potential as treatment for cytokine release syndrome in hospitalized COVID-19 patients. However, the presence of siltuximab can interfere with IL-6 assays, leading to the use of C-reactive protein (CRP) as a surrogate marker to monitor its efficacy. Aim To evaluate potential Siltuximab and Tocilizumab antibody interference on IL-6 measurements in three different IL-6 protein immunoassays. Method: Serum or EDTA plasma sample pools with different IL-6 concentrations ranging from low (2.3 – 11.1 pg/mL, around the reference interval cut-off for each assay) to high (18.5 – 1142 pg/mL), above reference interval cut-off for each assay) were utilized. Various concentrations of Siltuximab or Tocilizumab were spiked into the sample pools (at 10% of total volume) to achieve final concentrations up to 600 µg/mL and up to 300 µg/mL, respectively. Sample spiked with 10% saline were used as no-drug control. Three assays were used to measure IL-6 concentration: Beckman Access IL-6 assay on UniCel DxI 800 (Beckman Coulter), V-PLEX Plus human IL-6 assay on QuickPlex SQ120 (Meso Scale Diagnostics), and a Luminex cytokine panel assay developed in house (R&D systems) with upper reference interval limits of 6.4,1.8 and 5 pg/mL respectively. Results Siltuximab interfered with the measurement of IL-6 for all three assays. A significant interference (> 20% reduction) was observed at even a very low siltuximab concentrations in all three assays (0.05 µg/mL). In the presence of 5 µg/mL or greater Siltuximab, a maximum reduction of 93%, 83%, and 40% was observed for Beckman Access, R&D Luminex assay, and V-PLEX Plus Mesoscale assay, respectively. Tocilizumab did not interfere with the measurement of IL-6 in the three assays when serum was spiked with up to 300 µg/mL of the drug. Conclusion Siltuximab falsely reduce the measured IL-6 concentration on all three immunoassays tested in this study to differing degrees, whereas Tocilizumab does not. Consider the therapeutic range of Siltuximab (84 to 332 µg/mL) for treatment of Castleman disease, and a half-life of 20.6 days, measurement of IL-6 may not be useful in Siltuximab treated patients for an extended time-period.
Assessment of Improved Quality via the Adoption of Microbiology Automation
Lau, J. , Rice, Francine J., Lau, J, Larsen, J, Grys, Thomas E. , Rice, F, Graf, Erin H.

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S86-S86

10.1093/ajcp/aqad150.191 Get It

Abstract Introduction/Objective Our laboratory implemented a full COPAN WASPLab microbiology automation line in March of 2023. Prior to this implementation, our laboratory routinely observed potential bacterial contamination of sterile specimens, as well as culture plates in which the specimens were not struck out, due to a large number of new staff members and heavy workloads. Both of these quality issues directly impact patient care due to potential misleading or delayed results. We hypothesized that automation of the plating and incubation steps would reduce both of these quality issues significantly. Methods/Case Report Potential contamination and plates not struck were self-reported by technologists during pre- implementation (July 2022-Feb 2023) and post-implementation (Mar-Apr 2023) periods. Potential contamination was defined as one or two colonies of bacteria on a single agar plate, consistent with skin fora, from a normally sterile source specimen and reviewed by the Director for potential clinical correlation. Plates unstruck in the post- implementation period continued to include those manually set up. A 2 two proportion z-test was performed to compare pre and post implementation data. Results (if a Case Study enter NA) A total of 3,055 and 1,750 sterile source cultures were analyzed in the pre- and post-implementation periods, respectively. Of these, 109 versus 8 were designated as potential contamination, respectively, resulting in a significant reduction (Z stat 6.7, p<0.0001). For the plate streaking portion, 22,814 and 7,211 cultures were analyzed in the pre- and post-implementation periods, respectively. Of these, 21 versus 3 plates were not struck, respectively, resulting in a greater than 2-fold reduction per culture, but did not meet significance. Conclusion Implementation of microbiology automation significantly reduced skin flora contamination of sterile source cultures. Proportions of unstruck plates were also reduced, although these did not meet significance, likely due to the low numbers.
Sustained Culture of Safety After Select Agent Exposure
Larsen, Jeremy T. , Lau, Jocelyn , Karsten, Jaap, Wrobel, R. , Francis, D. P., Lau, J, Grys, Thomas E. , Graf, Erin H. , Wrobel, R

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S88-S88

10.1093/ajcp/aqad150.195 Get It

Abstract Introduction/Objective In January of 2021 our laboratory experienced the occupational exposure of 3 technologists to the select agent Burkholderia pseudomallei due to improper recognition and manipulation outside a biosafety cabinet. Subsequently, an interactive computer module was created to train technologists on timely recognition, followed by a “fake” patient test to evaluate comprehension. In that initial period, 100% compliance and successful recognition was demonstrated. To evaluate sustained compliance and recognition, another wave of evaluation was performed Jan- Dec 2022. Methods/Case Report During the study period several new staff members were hired and demonstrated compliance with completing the computer module. Clinical isolates suspicious for a select agent were reported to the Medical Director on rounds daily and reviewed for potential exposure, which was defined as manipulation of the suspicious isolate outside of the biosafety cabinet. Additional challenge “fake” patients were circulated. Results (if a Case Study enter NA) During the study period, 16 isolates were deemed suspicious for select agents based on macroscopic and microscopic morphology and biochemical reactions. Of these, 0 resulted in laboratory exposures. Of the challenge isolates, 1 resulted in a near-miss potential for exposure due to the lack of recognition of macroscopic characteristics. Conclusion The use of an interactive computer module focused around timely recognition and safe handling of potential select agents resulted in sustained laboratory safety and avoidance of potential occupational exposures.
A stochastic multicompartment model of hemostasis and oxygenation during trauma resuscitation as a platform for in silico trials of transfusion
Vieni, Casey , Yazer, Mark H. , Seheult, Jansen N. , Seheult, Jansen N

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S121-S122

10.1093/ajcp/aqad150.265 Get It

Abstract Uncontrolled hemorrhage accounts for up to 40% of trauma related mortality, and approximately 30% of trauma related deaths occur in the hospital within the first 1-4 hours of injury. The Advanced Trauma Life Support (ATLS) guidelines still recommend initial resuscitation with crystalloid fluid as an integral part of maintaining or restoring hemodynamic stability, but are starting to recognize the role of early resuscitation with blood products in patients with evidence of Class III and IV hemorrhage, in line with recent clinical trial and observational data. Although there is a growing body of evidence that early transfusion with blood products may be associated with improved survival compared with crystalloid infusion, the optimal transfusion strategy still remains unclear and is being actively investigated in clinical trials. In silico models of resuscitation offer a means to evaluate the effectiveness and safety of resuscitation protocols, including effects on body fluid compartment volumes, tissue oxygenation, and hemostatic factors. Here we describe our work extending earlier deterministic models of trauma resuscitation to incorporate hemodynamic, hemostatic, resuscitation, biomarker, and tissue-oxygenation domains into a single comprehensive model. Additionally, this model expands upon previous deterministic models to create a stochastic computational model of hemostatic resuscitation that accounts for variations in blood component composition and temporal features of transfusion therapy. Using this stochastic model, an in silico trial was piloted to compare conventional component therapy, i.e. red cell, platelet and plasma components, to cold-stored whole blood using the following starting assumptions: patient weight of 81.3±21.8 kg, hematocrit of 41.8±4.3%, initial bleeding rate between 50 and 150 mL/min, systolic blood pressure of 125±18 mmHg, fibrinogen of 293±88 mg/dL, international normalized ratio of 1.0±0.1 and platelet count of 239±62x109/L, with blood component and whole blood constituent distributions based on laboratory quality control data. This in silico trial demonstrated that resuscitation with whole blood was associated with a 28-minute reduction in the time spent in the critical window defined by platelet count <50x109/L, INR≥2, hemoglobin <9 g/dL and fibrinogen <150 mg/dL compared with conventional component resuscitation over the course of a 4 hour simulation (p<0.001 based on median regression). We demonstrate how stochastic models of hemostatic resuscitation can be used to perform in silico trials of resuscitation strategies. Our work can guide inclusion and exclusion criteria for future clinical trials and facilitate identification of patient subgroups most likely to benefit from certain resuscitation strategies. This work was partially funded by the AABB Foundation (formerly the National Blood Foundation).
Predicting treatment response to methotrexate: are we closer to solving the enigma?
Myasoedova, Elena , Myasoedova, Elena

Rheumatology | November 29, 2023 | Volume: 63 | Issue: 6 | Pages: 1479-1480

10.1093/rheumatology/kead622 | PMID 38019954 Get It

Orthopnea Secondary to Brachial Plexitis with Bilateral Diaphragmatic Paralysis
Labban, Mohamad El , Bauer, Philippe R.

No container title available | November 29, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-3635073/v1 Get It

Abstract Background: Diaphragmatic paralysis can present with orthopnea. We report a unique presentation of bilateral diaphragmatic paralysis, an uncommon diagnosis secondary to an unusual cause, brachial plexitis. This report thoroughly describes the patient’s presentation, workup, management, and outcome. It also reviews the literature on diaphragmatic paralysis and Parsonage-Turner syndrome. Case presentation: A 50-year-old male patient developed insidious orthopnea associated with left shoulder and neck pain over three months with no associated symptoms. On examination, marked dyspnea was observed when the patient was asked to lie down; breath sounds were present and symmetrical, and the neurological examination was normal. The chest radiograph showed an elevated right hemidiaphragm. Echocardiogram was normal. There was a 63% positional reduction in Forced Vital Capacity and maximal inspiratory and expiratory pressures on pulmonary function testing. The electromyogram was consistent with neuromuscular weakness involving both brachial plexus and diaphragmatic muscle (Parsonage and Turner syndrome). Conclusions: Compared to unilateral, bilateral diaphragmatic paralysis may be more challenging to diagnose. On PFT, reduced maximal respiratory pressures, especially the maximal inspiratory pressure, are suggestive. Parsonage-Turner syndrome is rare, usually with unilateral diaphragmatic paralysis, but bilateral cases have been reported.
Surgeon Sex and Health Care Costs for Patients Undergoing Common Surgical Procedures
Aminoltejari, Khatereh, Kaneshwaran, Kirusanthy , Salles, Arghavan , Buntin, Melinda Beeuwkes, Coburn, Natalie G. , Wright, Frances C. , Conn, Lesley Gotlib , Heybati, Kiyan , Luckenbaugh, Amy N. , Riveros, Carlos , McCartney, Colin J. L. , Bass, Barbara L. , Detsky, Allan S. , Satkunasivam, Raj , Wallis, Christopher J D , Jerath, Angela , Ranganathan, Sanjana , Armstrong, Kathleen

JAMA Surgery | November 29, 2023 | Volume: 159 | Issue: 2 | Pages: 151

10.1001/jamasurg.2023.6031 | PMID 38019486 Get It

ImportancePrior research has shown differences in postoperative outcomes for patients treated by female and male surgeons. It is important to understand, from a health system and payer perspective, whether surgical health care costs differ according to the surgeon’s sex.ObjectiveTo examine the association between surgeon sex and health care costs among patients undergoing surgery.Design, Setting, and ParticipantsThis population-based, retrospective cohort study included adult patients undergoing 1 of 25 common elective or emergent surgical procedures between January 1, 2007, and December 31, 2019, in Ontario, Canada. Analysis was performed from October 2022 to March 2023.ExposureSurgeon sex.Main Outcome and MeasureThe primary outcome was total health care costs assessed 1 year following surgery. Secondarily, total health care costs at 30 and 90 days, as well as specific cost categories, were assessed. Generalized estimating equations were used with procedure-level clustering to compare costs between patients undergoing equivalent surgeries performed by female and male surgeons, with further adjustment for patient-, surgeon-, anesthesiologist-, hospital-, and procedure-level covariates.ResultsAmong 1 165 711 included patients, 151 054 were treated by a female surgeon and 1 014 657 were treated by a male surgeon. Analyzed at the procedure-specific level and accounting for patient-, surgeon-, anesthesiologist-, and hospital-level covariates, 1-year total health care costs were higher for patients treated by male surgeons ($24 882; 95% CI, $20 780-$29 794) than female surgeons ($18 517; 95% CI, $16 080-$21 324) (adjusted absolute difference, $6365; 95% CI, $3491-9238; adjusted relative risk, 1.10; 95% CI, 1.05-1.14). Similar patterns were observed at 30 days (adjusted absolute difference, $3115; 95% CI, $1682-$4548) and 90 days (adjusted absolute difference, $4228; 95% CI, $2255-$6202).Conclusions and RelevanceThis analysis found lower 30-day, 90-day, and 1-year health care costs for patients treated by female surgeons compared with those treated by male surgeons. These data further underscore the importance of creating inclusive policies and environments supportive of women surgeons to improve recruitment and retention of a more diverse and representative workforce.
Cold Versus Hot Endoscopic Mucosal Resection for Sessile Serrated Colorectal Polyps ≥10 mm
Malik, Talia F. , Deliwala, Smit , Kassab, Lena L., Chandan, Saurabh , Sharma, Neil , Chandan, Saurabh , Mohan, Babu P. , Adler, Douglas G.

Journal of Clinical Gastroenterology | November 29, 2023 | Volume: 58 | Issue: 9 | Pages: 889-895

10.1097/mcg.0000000000001951 | PMID 38019045 Get It

Introduction: We performed a systematic review and meta-analysis studying the efficacy and safety of cold versus hot endoscopic mucosal resection (EMR) for resection of sessile serrated polyps (SSPs) ≥10 mm. Methods: Multiple databases were searched until January 2023 for studies reporting outcomes of cold versus hot EMR for SSPs ≥10 mm. The primary outcome was the residual SSP rate. Secondary outcomes included technical success rate, R0 resection rate, and adverse events. We used standard meta-analysis methods using the random-effects model, and I 2% was used to assess heterogeneity. Results: Thirteen studies were included in the final analysis. In all, 1896 SSPs were included with a mean polyp size of 23.7 mm (range, 15.9 to 33). A total of 1452 SSPs were followed up for a median follow-up duration of 15.3 months (range, 6 to 37). The pooled residual SSP rate for cold EMR was 4.5% (95% CI: 1.0-17.4), and 5.1% (95% CI: 2.4-10.4) for hot EMR (P=0.9). The pooled rates of technical success, R0 resection, immediate bleeding, and perforation were comparable. Hot EMR was significantly associated with lower piecemeal resection (59.2% vs. 99.3%, P<0.001), higher en-bloc resection (41.4% vs. 1.4%, P<0.001), and delayed bleeding rate (4% vs. 0.7%, P=0.05) compared to cold EMR. Conclusions: Cold EMR has similar efficacy compared to hot EMR for resection of SSP ≥ 10 mm, despite limitations in piecemeal R0 resection rate reporting. Although hot EMR was associated with a higher rate of en-bloc resection, it also showed an increased risk of delayed bleeding compared to cold EMR.