Cockerill, Franklin R.

A5028896212 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 58

Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 6 | Pages: 2233-2236

10.1128/jcm.39.6.2233-2236.2001 | PMID 11376062

ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method ( P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles ( P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) ( P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.
Culture with BACTEC Peds Plus/F Bottle Compared with Conventional Methods for Detection of Bacteria in Synovial Fluid

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4468-4471

10.1128/jcm.39.12.4468-4471.2001 | PMID 11724863

ABSTRACT An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens. The Peds Plus/F bottle was used because in our laboratory the quantity of synovial fluid available for culture is frequently in the range of 0.5 to 3.0 ml. The culture results obtained with the Peds Plus/F bottle were compared to those obtained by a conventional agar plate method for a total of 805 synovial fluid specimens. Microbial growth was produced by 74 cultures (9.2%) from 60 patients, yielding a total of 77 microorganisms. Organisms were classified as pathogens ( n = 62), contaminants ( n = 12), or indeterminate ( n = 3) on the basis of a review of the patients' medical histories. Culture using BACTEC Peds Plus/F bottle detected statistically significantly more pathogens overall (62 versus 51 pathogens [ P = 0.001]) and statistically fewer contaminants overall (1 versus 11 contaminants [ P = 0.006]) than culture by the agar plate method. These results indicate the superior performance of the BACTEC Peds Plus/F bottle over the conventional agar plate method for the detection of clinically significant microorganisms from synovial fluid specimens.
Comparison of the BACTEC MYCO/F Lytic Bottle to the Isolator Tube, BACTEC Plus Aerobic F/Bottle, and BACTEC Anaerobic Lytic/10 Bottle and Comparison of the BACTEC Plus Aerobic F/Bottle to the Isolator Tube for Recovery of Bacteria, Mycobacteria, and Fungi

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4380-4386

10.1128/jcm.39.12.4380-4386.2001 | PMID 11724848

ABSTRACT The BACTEC MYCO/F Lytic blood culture bottle (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is designed to optimize the recovery of fungi and mycobacteria; however, this bottle also supports the growth of most aerobic bacteria. We compared the MYCO/F Lytic bottle with two other BACTEC bottles and the Isolator system for the recovery of bacteria as well as fungi and mycobacteria from blood. A total of 6,108 blood culture sets were inoculated with blood obtained from adult patients. Twenty-five to 28 ml of blood collected by a phlebotomy team for each blood culture set was randomly distributed into each of four blood culture receptacles: the Isolator tube (Wampole Laboratories, Cranbury, N.J.) and three BACTEC bottles: the MYCO/F Lytic bottle, the BACTEC Plus Aerobic/F bottle, and the BACTEC Anaerobic Lytic/10 bottle. The sediment from the Isolator tube was inoculated onto chocolate agar (CA), brain heart infusion agar (BHI), and Sabouraud dextrose agar (SDA) and into a BACTEC 13A bottle. Incubation durations were as follows: MYCO/F Lytic bottle, 42 days; Plus Aerobic/F bottle, 5 days; Anaerobic Lytic/10 bottle, 5 days; sediment from Isolator tube on CA, 3 days; sediment from Isolator tube on BHI, 30 days; sediment from Isolator tube on SDA, 30 days; and sediment from Isolator tube in a BACTEC 13A bottle, 42 days. Two isolates of Histoplasma capsulatum were recovered from the Isolator tube only. Three isolates of Mycobacterium tuberculosis complex were recovered: two isolates from the MYCO/F Lytic bottle only and one isolate from the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle) only. Two isolates of Cryptococcus neoformans were recovered: one from the MYCO/F Lytic bottle only and the other from the MYCO/F Lytic bottle and the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle). For potential pathogens overall, there was a statistical difference in recovery that favored the Isolator system over the MYCO/F Lytic bottle ( P = 0.0015), including statistically significant differences for Staphylococcus aureus ( P = 0.0001) and Streptococcus pneumoniae ( P = 0.0313). However, there was no statistically significant difference between the two blood culture systems when detection of bloodstream infection was considered. The time to detection for all potential pathogens combined was less for the MYCO/F Lytic bottle than for the Isolator system ( P = 0.0004). Overall, the potential pathogen recovery was greater for the BACTEC Plus Aerobic/F bottle than for either the Isolator system ( P = 0.0003) or the MYCO/F Lytic bottle ( P = 0.0001). However, the BACTEC Plus Aerobic/F bottle did not recover M. tuberculosis , H. capsulatum , or C. neoformans isolates. The combination of the Isolator system and MYCO/F Lytic bottle may be useful as a selective blood culture method to optimize the recovery of fungi and mycobacteria from blood. Compared with the manual Isolator system, the MYCO/F Lytic system has the advantage of less preanalytic processing and continuous automated monitoring of bottles for growth by the BACTEC 9240 instrument.
In Vivo and In Vitro Studies of Cytosolic Phospholipase A2Expression inHelicobacter pyloriInfection

Infection and Immunity | July 27, 2002 | Volume: 69 | Issue: 9 | Pages: 5857-5863

10.1128/iai.69.9.5857-5863.2001 | PMID 11500464

ABSTRACTModifications of mucosal phospholipids have been detected in samples from patients withHelicobacter pylori-positive gastritis. These alterations appear secondary to increased phospholipase A2activity (PLA2). The cytosolic form of this enzyme (cPLA2), normally involved in cellular signaling and growth, has been implicated in cancer pathogenesis. The aim of this study was to investigate cPLA2expression and PLA2activity in the gastric mucosae of patients with and withoutH. pyloriinfection. In gastric biopsies from 10H. pylori-positive patients, cPLA2levels, levels of mRNA as determined by reverse transcriptase PCR, levels of protein as determined by immunohistochemistry, and total PLA2activity were higher than in 10H. pylori-negative gastritis patients. To clarify whetherH. pylorihad a direct effect on the cellular expression of cPLA2, we studied cPLA2expression in vitro with different human epithelial cell lines, one from a patient with larynx carcinoma (i.e., HEp-2 cells) and two from patients with gastric adenocarcinoma (i.e., AGS and MKN 28 cells), incubated with differentH. pyloristrains. The levels of cPLA2, mRNA, and protein expression were unchanged in Hep-2 cells independently of cellular adhesion or invasion of the bacteria. Moreover, no change in cPLA2protein expression was observed in AGS or MKN 28 cells treated with wild-typeH. pylori. In conclusion, our study shows increased cPLA2expression and PLA2activity in the gastric mucosae of patients withH. pyloriinfection and no change in epithelial cell lines exposed toH. pylori.
Direct Identification of Bacteria from Positive Blood Cultures by Amplification and Sequencing of the 16S rRNA Gene: Evaluation of BACTEC 9240 Instrument True- Positive and False-Positive Results

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 10 | Pages: 3578-3582

10.1128/jcm.39.10.3578-3582.2001 | PMID 11574575

ABSTRACT In a previous study which evaluated the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.), we noted a 1.3% “instrument false-positive” rate. That is, the BACTEC system signaled that a bottle (BACTEC Plus Aerobic/F bottle or BACTEC Anaerobic Lytic/10 bottle) culture was positive but a Gram stain was negative and there was no growth of bacteria or yeasts on subculture to chocolate agar. Furthermore, from the same sample of blood, cultures for fungi using the Isolator blood culture system (Wampole Laboratories, Cranbury, N.J.) were negative for growth. For the present study, we evaluated 76 instrument false-positive samples for the presence of 16S ribosomal DNA using the MicroSeq 500 kit (PE Biosystems, Foster City, Calif.). These samples also were negative for fungi by the Isolator method. This kit has a PCR module and sequencing module for the amplification and sequencing of the 16S RNA gene and provides a database for sequence alignment and identification of bacteria. To optimize the assay, we evaluated the effect of adding 0.5% bovine serum albumin to the sample from blood culture bottles and found that it decreased the effects of inhibitors on the PCR. Two control groups of blood culture specimens were also evaluated. One group ( n = 45) were “instrument true positives”; the instrument signaled positive, and subsequent Gram stains were positive and subcultures on chocolate agar grew bacteria. The other group ( n = 20) were “instrument true negatives”; the instrument signaled negative, the Gram stain was negative, and subcultures on chocolate agar and from the Isolator tube on fungal media showed no growth. None of the 76 instrument false-positive samples had evidence for 16S rRNA gene sequences. All of the instrument true-positive samples and all of the instrument true-negative specimens were positive and negative, respectively, using the MicroSeq 500 kit. Total peripheral white blood cell counts were statistically significantly higher for patients who had instrument false-positive results than for patients who had instrument true-positive or true-negative results ( P = 0.001). We conclude that instrument false positives signaled by the BACTEC 9240 system are not due to bacteria in the blood culture samples.
Frequency of Isolation of Staphylococcus lugdunensis in Consecutive Urine Cultures and Relationship to Urinary Tract Infection

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 2 | Pages: 654-656

10.1128/jcm.40.2.654-656.2002 | PMID 11825988

ABSTRACT Recent reports associate Staphylococcus lugdunensis with severe infection in humans. The frequency of this microorganism in urine cultures is unknown. Five hundred isolates of coagulase-negative staphylococci (CoNS) were recovered from 4,652 consecutive urine specimens submitted for culture to the Mayo Clinic Microbiology Laboratory. Thirty-one (6%) of 500 isolates of CoNS were identified as S. lugdunensis . In no case was S. lugdunensis isolated in pure culture; 29 (94%) of 31 S. lugdunensis isolates were part of mixed nonpathogenic flora. Medical records were reviewed for 30 of the 31 patients from whom these 31 isolates were isolated. Twenty-one (70%) of the 30 evaluable patients were not treated with antibiotics; the remaining 9 (30%) of 30 patients were treated with antibiotics that may be effective against S. lugdunensis. S. lugdunensis may be an unrecognized yet infrequent cause of urinary tract infection.
INFECTIVE ENDOCARDITIS CAUSED BY HACEK MICROORGANISMS

Annual Review of Medicine | July 27, 2002 | Volume: 48 | Issue: 1 | Pages: 25-33

10.1146/annurev.med.48.1.25 | PMID 9046942

▪ Abstract The HACEK group of fastidious gram-negative organisms is a recognized but unusual cause of infective endocarditis, responsible for approximately 3% of cases. We report our experience with 45 cases of endocarditis caused by HACEK organisms. In Olmsted County, Minnesota, the incidence of HACEK endocarditis was 0.14 per 100,000 person-years. In patients with native valves, 33 cases occurred, and in patients with prosthetic valves, 12 cases occurred. The most common presenting symptoms were fever, splenomegaly, new or changing murmur, and microvascular phenomena. Symptoms were present in the majority of patients anywhere from two weeks to six months prior to diagnosis. Blood cultures became positive in a mean of 3.375 days, and therapy with a beta-lactam alone or as part of a combination was given for anywhere between three and six weeks. Within the first month of diagnosis, surgery was performed for 13 regurgitant valves in 11 patients (24%). Echocardiography was an insensitive predictor of subsequent major arterial embolization (odds ratio, 1.33; 95% confidence interval, 0.31–5.67). The overall survival in our cohort of patients was 87%. These results confirm previous reports that HACEK endocarditis portends a favorable prognosis.
Multiplex LightCycler PCR Assay for Detection and Differentiation of Bordetella pertussis and Bordetella parapertussis in Nasopharyngeal Specimens

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 1 | Pages: 96-100

10.1128/jcm.40.1.96-100.2002 | PMID 11773099

ABSTRACT A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS 481 and IS 1001 of B. pertussis and B. parapertussis , respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensitivity is less than one organism per reaction. Results for Bordetella culture and/or direct fluorescent antibody testing and a second LightCycler PCR assay (target, pertussis toxin gene) were compared to results of the LC-PCR-IS assay for 111 nasopharyngeal swabs submitted for pertussis testing. Of the specimens, 12 were positive (9 B. pertussis and 3 B. parapertussis ) and 68 specimens were negative by all methods. Three other specimens were positive for B. pertussis by at least two of the methods (including the LC-PCR-IS assay), and another 28 specimens were positive for B. pertussis by the LC-PCR-IS assay only. No specimens were negative by the LC-PCR-IS assay and positive by the other methods. A conventional PCR method (target, IS 481 ) was also compared to the LC-PCR-IS assay for a different group of nasopharyngeal swab specimens ( n = 96): 44 specimens were positive and 41 specimens were negative for B. pertussis with both PCR methods. Nine specimens were positive for B. pertussis by the LC-PCR-IS assay and negative by the conventional PCR assay, and two specimens were positive for B. pertussis by the conventional PCR assay and negative by the LC-PCR-IS assay. Positivity of the two assays was not significantly different ( P = 0.0654). The insertion sequence IS 481 is also present in Bordetella holmesii ; specimens containing B . holmesii may yield false-positive results. The LC-PCR-IS assay takes approximately 45 min to complete post-nucleic acid extraction, compared to 24 h for the conventional PCR assay previously used in our laboratory. The LC-PCR-IS assay is easier to perform than the conventional PCR assay, and the closed system decreases the chance of contamination. All of these characteristics represent a significant improvement in the detection of B . pertussis and B . parapertussis in nasopharyngeal specimens.