Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli from Nonenriched Stool Specimens by Real-Time PCR in Comparison to Enzyme Immunoassay and Culture

Journal of Clinical Microbiology | May 14, 2009 | Volume: 47 | Issue: 7 | Pages: 2008-2012

10.1128/jcm.02013-08 | PMID 19439539

ABSTRACT Shiga toxin (Stx)-producing Escherichia coli (STEC) bacteria are a frequent cause of food-borne gastroenteritis, hemorrhagic colitis, and hemolytic uremic syndrome. Because antimicrobial agents are generally contraindicated in patients infected with STEC, a sensitive and specific diagnostic test with rapid turnaround is essential. Current culture methods may fail to detect non-O157 STEC. We evaluated a Stx gene real-time PCR assay using hybridization probes and the LightCycler instrument with 204 prospectively collected stool specimens, which were also tested for Stx by enzyme immunoassay (EIA) (ProSpecT STEC; Remel, Lenexa, KS) and by culturing on chromogenic agar (Chromagar O157; BD BBL, Sparks, MD). In addition, 85 archived stool specimens previously tested for Stx (by EIA) and/or E. coli O157:H7 (by culture) were tested by PCR. Sample preparation for PCR included mixing the stool in sterile water and extraction of nucleic acid using the MagNA Pure LC instrument (Roche Diagnostics). The PCR assay had 100% sensitivity and specificity compared to EIA and culture for specimens collected prospectively (4 of 204 specimens were positive) and compared to culture and/or EIA for archival specimens (42 of 85 specimens were positive). Both the EIA and PCR produced positive results from a specimen containing an O103 serotype STEC in the prospective specimens, and the PCR test detected three positive specimens that contained nonviable STEC in the archived specimens. The PCR assay demonstrated 100% sensitivity and specificity compared to EIA and/or culture and more rapid turnaround than either EIA or culture.
Comparison of Real-Time PCR for Detection of the tcdC Gene with Four Toxin Immunoassays and Culture in Diagnosis of Clostridium difficile Infection

Journal of Clinical Microbiology | April 24, 2008 | Volume: 46 | Issue: 6 | Pages: 1996-2001

10.1128/jcm.00032-08 | PMID 18434563

ABSTRACT We have developed a rapid real-time PCR method using fluorescence resonance energy transfer probes and the LightCycler (Roche Diagnostics), which will detect the presence of the tcdC gene of Clostridium difficile in stool samples. Our PCR method also will identify the presence of base pair deletions, one of which (18 bp) has been associated with the “epidemic” toxin-hyperproducing strains. We compared the results of this PCR with those of three C. difficile toxin-detecting enzyme immunoassays (EIAs), an EIA for the detection of glutamate dehydrogenase (GDH), and culture of C. difficile . A total of 200 stool specimens were studied by the methods under comparison. C. difficile was isolated from 49 specimens by culture, and 44 of these were confirmed as containing one of the genes associated with toxin production (“toxigenic culture”). Using toxigenic culture as the “gold standard”, the sensitivities, specificities, and positive and negative predictive values, respectively, of the assays were 48%, 98%, 88%, and 87% for the Premier toxin A and B test; 48%, 99%, 91%, and 87% for the ImmunoCard toxin A & B test; 48%, 84%, 46%, and 85% for the Xpect C. difficile toxin A/B test; 32%, 100%, 100%, and 84% for the Triage C. difficile panel (for toxin A); and 86%, 97%, 90%, and 96% for the LightCycler PCR. Thus, in comparison to the sensitivity of toxigenic culture, the sensitivities of the toxin immunoassays were unacceptably low, while the LightCycler real-time PCR assay for the detection of the tcdC gene of C. difficile is sensitive and specific.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

Clinical Microbiology Reviews | July 17, 2006 | Volume: 19 | Issue: 3 | Pages: 595-595

10.1128/cmr.00022-06

Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

Clinical Microbiology Reviews | January 17, 2006 | Volume: 19 | Issue: 1 | Pages: 165-256

10.1128/cmr.19.1.165-256.2006 | PMID 16418529

SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Detection of Tropheryma whipplei DNA in Clinical Specimens by LightCycler Real-Time PCR

Journal of Clinical Microbiology | July 6, 2005 | Volume: 43 | Issue: 7 | Pages: 3516-3518

10.1128/jcm.43.7.3516-3518.2005 | PMID 16000494

ABSTRACT A real-time PCR method using the LightCycler (Roche Applied Science, Indianapolis, IN) was compared to a conventional PCR assay for the detection of Tropheryma whipplei in 321 clinical specimens. The LightCycler method had sensitivity and specificity comparable to the conventional method but required considerably less labor and time (3 h versus 3 to 5 days).
Comparison of the Roche LightCycler vanA / vanB Detection Assay and Culture for Detection of Vancomycin-Resistant Enterococci from Perianal Swabs

Journal of Clinical Microbiology | June 7, 2004 | Volume: 42 | Issue: 6 | Pages: 2636-2643

10.1128/jcm.42.6.2636-2643.2004 | PMID 15184445

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA / vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml ( n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml ( n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.
Comparison of the Borrelia DotBlot G, MarDx, and VIDAS Enzyme Immunoassays for Detecting Immunoglobulin G Antibodies to Borrelia burgdorferi in Human Serum

Journal of Clinical Microbiology | November 26, 2002 | Volume: 40 | Issue: 12 | Pages: 4782-4784

10.1128/jcm.40.12.4782-4784.2002 | PMID 12454196

ABSTRACT Three enzyme immunoassays, Borrelia DotBlot G (GenBio, San Diego, Calif.), MarDx EIA (MarDx Diagnostics, Inc., Carlsbad, Calif.), and VIDAS (bioMérieux, St. Louis, Mo.) were compared for their ability to detect immunoglobulin G antibodies to Borrelia burgdorferi in 100 human serum samples. The “gold standard” positive result for each of these samples was determined by Western immunoblot analysis (MarDx Marblot Test System) ( n = 99) or clinical signs and symptoms suggestive of Lyme disease with other laboratory results positive for B. burgdorferi ( n = 1). Based on these criteria for a gold standard positive result, 29 of the 100 samples tested were considered true positives and 71 were considered true negatives. The following sensitivities and specificities were noted, respectively, for each method: Borrelia DotBlot G, 93 and 90%; MarDx, 100 and 35%; and VIDAS, 100 and 92%. Because of high sensitivity and specificity and ease of use, the VIDAS test is an appealing method, especially for laboratories that perform high volumes of tests. The high sensitivity but low specificity of the MarDx method compared to the VIDAS and Borrelia DotBlot G methods requires that Western blot confirmatory tests be performed frequently. The Borrelia DotBlot G method has acceptable specificity but appears to lack sensitivity when compared to the VIDAS and MarDx methods.
Real-Time PCR Method for Detection of Encephalitozoon intestinalis from Stool Specimens

Journal of Clinical Microbiology | October 30, 2002 | Volume: 40 | Issue: 11 | Pages: 3922-3928

10.1128/jcm.40.11.3922-3928.2002 | PMID 12409353

ABSTRACT The prevalence of microsporidiosis is likely underestimated due to the labor-intensive, insensitive, and nonspecific clinical laboratory methods used for the diagnosis of this disease. A real-time PCR assay was designed to assess DNA extraction methods and to detect three Encephalitozoon species in feces. Modifications of the MagNA Pure LC DNA isolation kit protocol (Roche Applied Sciences, Indianapolis, Ind.) were compared by using the automated MagNA Pure LC instrument (Roche) and fecal specimens spiked with Encephalitozoon intestinalis spores. Extracted DNA was amplified by the LightCycler (Roche) PCR assay. Assay sensitivity, reproducibility, and efficiency were assessed by comparing threshold crossover values achieved with different extraction and storage conditions (fresh, refrigerated, frozen, and preserved specimens). Optimal extraction conditions were achieved by using a commercial buffer, tissue lysis buffer (Roche), as the specimen diluent. LightCycler PCR results were compared to those obtained from routine stool microscopy with trichrome blue stain. The lower limit of detection for the LightCycler PCR assay varied by storage conditions from 10 2 to 10 4 spores/ml of feces, a value which represented a significant improvement over that achieved by staining (≥1.0 × 10 6 spores/ml). Melting temperature analysis of the amplicons allowed for the differentiation of three Encephalitozoon species ( E . intestinalis , E . cuniculi , and E . hellem ). The assay is readily adaptable to the clinical laboratory and represents the first real-time PCR assay designed to detect Encephalitozoon species.
Multicenter Survey of the Changing In Vitro Antimicrobial Susceptibilities of Clinical Isolates of Bacteroides fragilis Group, Prevotella, Fusobacterium, Porphyromonas , and Pepto

Antimicrobial Agents and Chemotherapy | July 27, 2002 | Volume: 45 | Issue: 4 | Pages: 1238-1243

10.1128/aac.45.4.1238-1243.2001 | PMID 11257040

ABSTRACT In vitro surveys of antimicrobial resistance among clinically important anaerobes are an important source of information that can be used for clinical decisions in the choice of empiric antimicrobial therapy. This study surveyed the susceptibilities of 556 clinical anaerobic isolates from four large medical centers using a broth microdilution method. Piperacillin-tazobactam was the only antimicrobial agent to which all the isolates were susceptible. Similarly, imipenem, meropenem, and metronidazole were highly active (resistance, <0.5%), whereas the lowest susceptibility rates were noted for penicillin G, ciprofloxacin, and clindamycin. For most antibiotics, blood isolates were less susceptible than isolates from intra-abdominal, obstetric-gynecologic, and other sources. All isolates of the Bacteroides fragilis group were susceptible to piperacillin-tazobactam and metronidazole, while resistance to imipenem and meropenem was low (<2%). For these same isolates, resistance rates (intermediate and resistant MICs) to ampicillin-sulbactam, cefoxitin, trovafloxacin, and clindamycin were 11, 8, 7, and 29%, respectively. Among the individual species of the B. fragilis group, the highest resistance rates were noted among the following organism-drug combinations: for clindamycin, Bacteroides distasonis and Bacteroides ovatus ; for cefoxitin, Bacteroides thetaiotaomicron, B. distasonis , and Bacteroides uniformis; for ampicillin-sulbactam, B. distasonis, B. ovatus , and B. uniformis ; and for trovafloxacin, Bacteroides vulgatus . For the carbapenens, imipenem resistance was noted among B. fragilis and meropenem resistance was seen among B. fragilis, B. vulgatus , and B. uniformis . With few exceptions all antimicrobial agents were highly active against isolates of Prevotella, Fusobacterium, Porphyromonas , and Peptostreptococcus . These data further establish and confirm that clinically important anaerobes can vary widely in their antimicrobial susceptibilities. Fortunately most antimicrobial agents were active against the test isolates. However, concern is warranted for what appears to be a significant increases in resistance to ampicillin-sulbactam and clindamycin.
Evaluation of ColorPAC Giardia/Cryptosporidium Rapid Assay and ProSpecT Giardia/Cryptosporidium Microplate Assay for Detection of Giardia and Crypto

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4523-4525

10.1128/jcm.39.12.4523-4525.2001 | PMID 11724874

ABSTRACT Detection of Giardia and Cryptosporidium in clinical stool specimens using the ColorPAC and ProSpecT enzyme immunoassays revealed 98.7% agreement for Giardia detection and 98.1% agreement for Cryptosporidium detection. Sensitivities were uniformly 100%. The specificities of the ColorPAC immunoassay for Giardia and Cryptosporidium detection were 100 and 99.5%, respectively, and those for the ProSpecT assay were 98.4 and 98.6%, respectively. The false-positive reactions with the ProSpecT assay occurred with specimens that were grossly bloody.