Citations 465

Evaluation of treatment of methicillin-resistant Staphylococcus aureus biofilms with intermittent electrochemically generated H 2 O 2 or HOCl

Antimicrobial Agents and Chemotherapy | May 21, 2024 | Volume: 68 | Issue: 7 | Pages: No page available

10.1128/aac.01722-23 | PMID 38771032

ABSTRACT Chronic wound infections can be difficult to treat and may lead to impaired healing and worsened patient outcomes. Novel treatment strategies are needed. This study evaluated the effects of intermittently produced hydrogen peroxide (H 2 O 2 ) and hypochlorous acid (HOCl), generated via an electrochemical bandage (e-bandage), against methicillin-resistant Staphylococcus aureus biofilms in an agar membrane biofilm model. By changing the working electrode potential, the e-bandage generated either HOCl (1.5 V Ag/AgCl ) or H 2 O 2 (−0.6 V Ag/AgCl ). The degree of biocidal activity of intermittent treatment with HOCl and H 2 O 2 correlated with HOCl treatment time; HOCl treatment durations of 0, 1.5, 3, 4.5, and 6 hours (with the rest of the 6-hour total treatment time devoted to H 2 O 2 generation) resulted in mean biofilm reductions of 1.36 ± 0.2, 2.22 ± 0.16, 3.46 ± 0.38, 4.63 ± 0.74, and 7.66 ± 0.5 log CFU/cm 2 , respectively, vs. non-polarized controls, respectively. However, application of H 2 O 2 immediately after HOCl treatment was detrimental to biofilm removal. For example, 3 hours HOCl treatment followed by 3 hours H 2 O 2 resulted in a 1.90 ± 0.84 log CFU/cm 2 lower mean biofilm reduction than 3 hours HOCl treatment followed by 3 hours non-polarization. HOCl generated over 3 hours exhibited biocidal activity for at least 7.5 hours after e-bandage operation ceased; 3 hours of HOCl generation followed by 7.5 hours of non-polarization resulted in a biofilm cell reduction of 7.92 ± 0.12 log CFU/cm 2 vs. non-polarized controls. Finally, intermittent treatment with HOCl (i.e., interspersed with periods of e-bandage non-polarization) for various intervals showed similar effects (approximately 6 log CFU/cm 2 reduction vs. non-polarized control) to continuous treatment with HOCl for 3 hours, followed by 3 hours of non-polarization. These findings suggest that timing and sequencing of HOCl and H 2 O 2 treatments are crucial for maximizing biofilm control when using an e-bandage strategy.
Phage K exposure generates phage-neutralizing activity in a rabbit model—humoral receptiveness may impact efficacy of phage therapy

Antimicrobial Agents and Chemotherapy | May 8, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1128/aac.00052-24 | PMID 38717092

ABSTRACT Phage therapy has not been established in the clinical routine, in part due to uncertainties concerning efficacy and immunogenicity. Here, three rabbits were immunized against staphylococcal phage K to assess viral potency in the presence of immunized serum. Three rabbits received weekly intramuscular injections of ~10 10±1 pfu/mL phage K. Phage K-specific IgG formation was measured by an enzyme-linked immunosorbent assay (ELISA); phage inactivation was assessed by calculating K-rates. Using transmission electron microscopy (TEM) and immunogold labeling, antibody binding to phage K was visualized. This was numerically assessed by objective imaging analysis comparing the relative distances of each gold particle to the nearest phage head and tail structure. Immunization led to a strong IgG response, plateauing 7 days after the last phage injection. There was no significant correlation between K-rate and antibody titer over time. TEM showed IgG binding to the head structure of phage K. Image analysis showed a significant reduction in relative distances between antibodies and phage head structures when comparing samples from day 0 and day 28 ( P < 0.0001). These results suggest that while individual serum analysis for antibodies against therapeutic phage bears consideration prior to and with prolonged therapy, during phage application, the formation of specific antibodies against phage may only partially explain decreased phage potency in the presence of immunized serum. Instead, other factors may contribute to an individual’s “humoral receptiveness” to phage therapy. Future investigations should be directed toward the identification of the humoral factors that have the most significant predictive value on phage potency in vivo .
Practical Guidance for Clinical Microbiology Laboratories: Microbiologic diagnosis of implant-associated infections

Clinical Microbiology Reviews | March 20, 2024 | Volume: 37 | Issue: 2 | Pages: No page available

10.1128/cmr.00104-23 | PMID 38506553

SUMMARY Implant-associated infections (IAIs) pose serious threats to patients and can be associated with significant morbidity and mortality. These infections may be difficult to diagnose due, in part, to biofilm formation on device surfaces, and because even when microbes are found, their clinical significance may be unclear. Despite recent advances in laboratory testing, IAIs remain a diagnostic challenge. From a therapeutic standpoint, many IAIs currently require device removal and prolonged courses of antimicrobial therapy to effect a cure. Therefore, making an accurate diagnosis, defining both the presence of infection and the involved microorganisms, is paramount. The sensitivity of standard microbial culture for IAI diagnosis varies depending on the type of IAI, the specimen analyzed, and the culture technique(s) used. Although IAI-specific culture-based diagnostics have been described, the challenge of culture-negative IAIs remains. Given this, molecular assays, including both nucleic acid amplification tests and next-generation sequencing-based assays, have been used. In this review, an overview of these challenging infections is presented, as well as an approach to their diagnosis from a microbiologic perspective.
Evaluation of Sonicate Fluid Culture Cutoff Points for Periprosthetic Joint Infection Diagnosis

Open Forum Infectious Diseases | March 19, 2024 | Volume: 11 | Issue: 5 | Pages: No page available

10.1093/ofid/ofae159 | PMID 38715572

Abstract Introduction Implant sonication is useful for recovery of periprosthetic joint infection (PJI) pathogens in culture, but exact cutoff points for definition of clinically significant sonicate fluid culture results vary from study to study. The aim of this study was to define ideal sonicate fluid culture cutoff points for PJI diagnosis. Methods Sonicate fluid cultures from hip and knee prosthesis components removed between February 2007 and December 2020 were studied. Prosthesis components were placed in solid containers in the operating room; in the clinical microbiology laboratory, 400 mL Ringer's solution was added, and containers subjected to vortexing, sonication and then vortexing, followed by centrifugation. Concentrated sonicate fluid was plated on aerobic and anaerobic solid media, and culture results reported semiquantitatively, as no growth, &lt;20, 20–50, 51–100, or &gt;100 CFU/10 mL sonicate fluid. Sonicate cultures from cement spacers and cultures yielding more than 1 microorganism were excluded. Sensitivity and specificity of each cutoff point was evaluated. Results A total of 1448 sonicate fluid cultures were evaluated, 68% from knees and 32% from hips. PJI was present in 644 (44%) cases. Sensitivity of sonicate culture was 75.0% at &lt;20 CFU/10 mL, 55.3% at ≥20 CFU/10 mL, 46.9% at &gt;51 CFU/10 mL, and 39.8% at &gt;100 CFU/10 mL. Specificity was 78.2%, 99.8%, 100%, and 100%, at the 4 cutoff points, respectively. Conclusions A cutoff point for sonicate fluid culture positivity of ≥20 CFU/10 mL is suitable for PJI diagnosis.
Infectious Diseases Society of America Guidelines on the Diagnosis of Coronavirus Disease 2019: Serologic Testing

Clinical Infectious Diseases | March 15, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/cid/ciae121 | PMID 38489670

Abstract Background The role of serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has evolved during the pandemic as seroprevalence in global populations has increased. The Infectious Diseases Society of America convened an expert panel to perform a systematic review of the coronavirus disease 2019 (COVID-19) serology literature and construct updated best practice guidance related to SARS-CoV-2 serologic testing. This guideline is an update to the fourth in a series of rapid, frequently updated COVID-19 guidelines developed by the Infectious Diseases Society of America. Objective To develop evidence-based recommendations and identify unmet research needs pertaining to the use of anti–SARS-CoV-2 antibody tests for diagnosis, decisions related to vaccination and administration of monoclonal antibodies or convalescent plasma in immunocompromised patients, and identification of a serologic correlate of immunity. Methods A multidisciplinary panel of infectious diseases clinicians, clinical microbiologists, and experts in systematic literature reviewed, identified, and prioritized clinical questions related to the use of SARS-CoV-2 serologic tests. Grading of Recommendations Assessment, Development and Evaluation methodology was used to assess the certainty of evidence and make testing recommendations. Results The panel recommends against serologic testing to diagnose SARS-CoV-2 infection in the first 2 weeks after symptom onset (strong recommendations, low certainty of evidence). Serologic testing should not be used to provide evidence of COVID-19 in symptomatic patients with a high clinical suspicion and repeatedly negative nucleic acid amplification test results (strong recommendation, very low certainty of evidence). Serologic testing may assist with the diagnosis of multisystem inflammatory syndrome in children (strong recommendation, very low certainty of evidence). To seek evidence for prior SARS-CoV-2 infection, the panel suggests testing for immunoglobulin G (IgG), IgG/IgM, or total antibodies to nucleocapsid protein 3 to 5 weeks after symptom onset (conditional recommendation, low certainty of evidence). In individuals with previous SARS-CoV-2 infection or vaccination, the panel suggests against routine serologic testing given no demonstrated benefit to improving patient outcomes (conditional recommendation, very low certainty of evidence). The panel acknowledges further that a negative spike antibody test may be a useful metric to identify immunocompromised patients who are candidates for immune therapy. Conclusions The high seroprevalence of antibodies against SARS-CoV-2 worldwide limits the utility of detecting anti-SARS CoV-2 antibody. The certainty of available evidence supporting the use of serology for diagnosis was graded as very low to low. Future studies should use serologic assays calibrated to a common reference standard.
Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM)

Clinical Infectious Diseases | February 23, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/cid/ciae104 | PMID 38442248

Abstract The critical nature of the microbiology laboratory in infectious disease diagnosis calls for a close, positive working relationship between the physician and the microbiologists who provide enormous value to the healthcare team. This document, developed by experts in both adult and pediatric laboratory and clinical medicine, provides information on which tests are valuable and in which contexts, and on tests that add little or no value for diagnostic decisions. Sections are divided into anatomic systems, including Bloodstream Infections and Infections of the Cardiovascular System, Central Nervous System Infections, Ocular Infections, Soft Tissue Infections of the Head and Neck, Upper Respiratory Infections, Lower Respiratory Tract Infections, Infections of the Gastrointestinal Tract, Intraabdominal Infections, Bone and Joint Infections, Urinary Tract Infections, Genital Infections, and Skin and Soft Tissue Infections; or into etiologic agent groups, including arboviral Infections, Viral Syndromes, and Blood and Tissue Parasite Infections. Each section contains introductory concepts, a summary of key points, and detailed tables that list suspected agents; the most reliable tests to order; the samples (and volumes) to collect in order of preference; specimen transport devices, procedures, times, and temperatures; and detailed notes on specific issues regarding the test methods, such as when tests are likely to require a specialized laboratory or have prolonged turnaround times. In addition, the pediatric needs of specimen management are also addressed. There is redundancy among the tables and sections, as many agents and assay choices overlap. The document is intended to serve as a reference to guide physicians in choosing tests that will aid them to diagnose infectious diseases in their patients.
In vitro activity of sulbactam-durlobactam against colistin-resistant and/or cefiderocol-non-susceptible, carbapenem-resistant Acinetobacter baumannii collected in U.S. hospitals

Antimicrobial Agents and Chemotherapy | January 30, 2024 | Volume: 68 | Issue: 3 | Pages: No page available

10.1128/aac.01258-23 | PMID 38289078

ABSTRACT The activity of a novel β-lactamase inhibitor combination, sulbactam-durlobactam (SUL-DUR), was tested against 87 colistin-resistant and/or cefiderocol-non-susceptible carbapenem-resistant Acinetobacter baumannii clinical isolates collected from U.S. hospitals between 2017 and 2019. Among them, 89% and 97% were susceptible to SUL-DUR and imipenem plus SUL-DUR, with MIC 50 /MIC 90 values of 2 µg/mL/8 µg/mL and 1 µg/mL/4 µg/mL, respectively. The presence of amino acid substitutions in penicillin-binding protein 3, including previously reported A515V or T526S, was associated with SUL-DUR non-susceptibility.
HOCl-producing electrochemical bandage for treating Pseudomonas aeruginosa -infected murine wounds

Antimicrobial Agents and Chemotherapy | January 12, 2024 | Volume: 68 | Issue: 2 | Pages: No page available

10.1128/aac.01216-23 | PMID 38214514

ABSTRACT The growing threat of antibiotic-resistant bacterial pathogens necessitates the development of alternative antimicrobial approaches. This is particularly true for chronic wound infections, which commonly harbor biofilm-dwelling bacteria. A novel electrochemical bandage (e-bandage) delivering low-levels of hypochlorous acid (HOCl) was evaluated against Pseudomonas aeruginosa murine wound biofilms. 5 mm skin wounds were created on the dorsum of mice and infected with 10 6 colony-forming units (CFU) of P. aeruginosa . Biofilms were formed over 2 days, after which e-bandages were placed on the wound beds and covered with Tegaderm. Mice were administered Tegaderm-only (control), non-polarized e-bandage (no HOCl production), or polarized e-bandage (using an HOCl-producing potentiostat), with or without systemic amikacin. Purulence and wound areas were measured before and after treatment. After 48 hours, wounds were harvested for bacterial quantification. Forty-eight hours of polarized e-bandage treatment resulted in mean biofilm reductions of 1.4 log 10 CFUs/g ( P = 0.0107) vs non-polarized controls and 2.2 log 10 CFU/g ( P = 0.004) vs Tegaderm-only controls. Amikacin improved CFU reduction in Tegaderm-only ( P = 0.0045) and non-polarized control groups ( P = 0.0312) but not in the polarized group ( P = 0.3876). Compared to the Tegaderm-only group, there was less purulence in the polarized group ( P = 0.009). Wound closure was neither impeded nor improved by either polarized or non-polarized e-bandage treatment. Concurrent amikacin did not impact wound closure or purulence. In conclusion, an HOCl-producing e-bandage reduced P. aeruginosa in wound biofilms with no impairment in wound healing, representing a promising antibiotic-free approach for addressing wound infection.
Testing for Helicobacter pylori in an era of antimicrobial resistance

Journal of Clinical Microbiology | January 9, 2024 | Volume: 62 | Issue: 2 | Pages: No page available

10.1128/jcm.00732-23 | PMID 38193664

The Infectious Diseases Society of America Guidelines on the Diagnosis of COVID-19: Molecular Diagnostic Testing (December 2023)

Clinical Infectious Diseases | December 19, 2023 | Volume: 78 | Issue: 7 | Pages: e385-e415

10.1093/cid/ciad646 | PMID 38112284

Abstract Accurate molecular diagnostic tests are necessary for confirming a diagnosis of coronavirus disease 2019 (COVID-19) and for identifying asymptomatic carriage of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The number of available SARS-CoV-2 nucleic acid detection tests continues to increase as does the COVID-19 diagnostic literature. Thus, the Infectious Diseases Society of America (IDSA) developed an evidence-based diagnostic guideline to assist clinicians, clinical laboratorians, patients, and policymakers in decisions related to the optimal use of SARS-CoV-2 nucleic acid amplification tests. In addition, we provide a conceptual framework for understanding molecular diagnostic test performance, discuss nuances of test result interpretation in a variety of practice settings, and highlight important unmet research needs related to COVID-19 diagnostic testing. IDSA convened a multidisciplinary panel of infectious diseases clinicians, clinical microbiologists, and experts in systematic literature review to identify and prioritize clinical questions and outcomes related to the use of SARS-CoV-2 molecular diagnostics. Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology was used to assess the certainty of evidence and make testing recommendations. The panel agreed on 12 diagnostic recommendations. Access to accurate SARS-CoV-2 nucleic acid testing is critical for patient care, hospital infection prevention, and the public health response to COVID-19 infection. Information on the clinical performance of available tests continues to grow, but the quality of evidence of the current literature to support this updated molecular diagnostic guideline remains moderate to very low. Recognizing these limitations, the IDSA panel weighed available diagnostic evidence and recommends nucleic acid testing for all symptomatic individuals suspected of having COVID-19. In addition, testing is suggested for asymptomatic individuals with known or suspected contact with a COVID-19 case when the results will impact isolation/quarantine/personal protective equipment (PPE) usage decisions. Evidence in support of rapid testing and testing of upper respiratory specimens other than nasopharyngeal swabs, which offer logistical advantages, is sufficient to warrant conditional recommendations in favor of these approaches.