Citations 27

Analysis of Posttraumatic Stress Disorder, Depression, Anxiety, and Resiliency Within the Unique Population of Spontaneous Coronary Artery Dissection Survivors

Journal of the American Heart Association | April 28, 2020 | Volume: 9 | Issue: 9 | Pages: No page available

10.1161/jaha.119.014372 | PMID 32342736

Background Mental health after spontaneous coronary artery dissection ( SCAD ), a cause of myocardial infarction in young women, remains largely unexplored. We assessed the prevalence and severity of psychiatric symptoms after SCAD . Methods and Results Individuals with confirmed SCAD who consented to the Mayo Clinic “Virtual” Multicenter SCAD Registry were sent the Posttraumatic Stress Disorder Diagnostic Scale for Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition , Patient Health Questionnaire‐9, Generalized Anxiety Disorder‐7, Anxiety Sensitivity Index, Connor‐Davidson Resilience Scale, 36‐Item Short‐Form Health Survey, and an SCAD ‐specific questionnaire. Among 782 patients contacted, 512 surveys were returned. Most respondents were women (97.5%), with median age at time of SCAD and survey completion of 47 and 52 years, respectively. Eighty‐two percent had at least one trauma, with mild or more posttraumatic stress disorder symptoms in 28%. Symptoms of anxiety and depression were observed in 41% and 32%, respectively. On multivariable analysis, those of younger age at first SCAD and low resiliency scored higher on measures of trauma, anxiety, and depression. Those with higher anxiety sensitivity had more severe anxiety and posttraumatic stress disorder symptoms. Emotional and social quality of life was higher in those with high resiliency scores. Time from SCAD event to survey completion was associated with lower Generalized Anxiety Disorder‐7 score severity. Conclusions Survivors of SCAD have significant rates of posttraumatic stress disorder, depression, and anxiety, which are associated with lower quality of life specifically among those with lower resiliency. Given the prevalence and potential impact, screening and treatment for the psychological distress is advised. Behavioral interventions targeted toward resiliency training may be beneficial for this patient population.
Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique

Acta Radiologica | January 27, 2020 | Volume: 61 | Issue: 9 | Pages: 1186-1195

10.1177/0284185119898655 | PMID 31986894

Background Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. Purpose To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. Material and Methods CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. Results Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m 2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18–1.28 vs. 1.02–1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar ( P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). Conclusion This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.
CT angiogram findings in carotid-cavernous fistulas: stratification of imaging features to help radiologists avoid misdiagnosis

Acta Radiologica | November 8, 2019 | Volume: 61 | Issue: 7 | Pages: 945-952

10.1177/0284185119885119 | PMID 31698923

Background Carotid-cavernous fistulas (CCFs) are commonly misdiagnosed on computed tomography angiography (CTA). Purpose This study sought to identify the most sensitive and specific imaging features of CCFs on CTA. Material and Methods A retrospective review identified 18 consecutive patients suspected of having a CCF on CTA and subsequently underwent digital subtraction angiography (DSA). Two blinded reviewers assessed multiple findings on CTA: cavernous sinus asymmetry/enlargement; arterial-phase contrast in the cavernous sinus; proptosis; pre- or post-septal orbital edema; and dilated regional vasculature. Each was graded as positive, possible, and negative; “possible” was counted as positive. A third blinded reviewer served as a tiebreaker. Results Of 18 patients, nine were true-positive and nine were false-positive. Superior ophthalmic vein early enhancement and dilatation had 100.0% sensitivity (95% confidence interval [CI] 40.0–100.0) and 77.8% specificity (95% CI 44.4–100.0); arterial-phase contrast in the cavernous sinus had 88.9% sensitivity (95% CI 44.4–100.0) and 66.7% specificity (95% CI 18.5–90.1); peri-orbital edema had 88.9% sensitivity (95% CI 35.5–100.0) and 77.8% specificity (95% CI 22.2–100.0). The most specific markers of CCF were superior petrosal sinus and inferior ophthalmic vein dilatation/enhancement (100.0%, 95% CI 88.8–100.0 and 88.9%, 95% CI 44.4–100.0, respectively); the specificity of asymmetric cavernous enlargement was 44.4% (95% CI 11.1–77.7). Conclusions Among patients in whom a CCF is suspected on CTA, superior ophthalmic vein dilatation/enhancement and arterial-phase contrast within the cavernous sinus are the most sensitive findings. Asymmetric cavernous sinus enlargement has poor specificity and may result in false-positive diagnoses of CCFs. False positive cases were less likely to have an optimally timed contrast bolus.
Molecular Breast Imaging in Patients with Suspicious Calcifications

Journal of Breast Imaging | October 31, 2019 | Volume: 1 | Issue: 4 | Pages: 303-309

10.1093/jbi/wbz054 | PMID 38424809

AbstractObjectiveWe evaluated the accuracy of molecular breast imaging (MBI)—a nuclear medicine technique that employs dedicated dual-detector, cadmium zinc telluride gamma cameras to image the functional uptake of a radiopharmaceutical (typically Tc-99m sestamibi) in the breast—in patients with suspicious calcifications on mammography.MethodsWomen scheduled for stereotactic biopsy of calcifications detected on 2D digital mammography were prospectively enrolled to undergo MBI before biopsy. Molecular breast imaging was performed with injection of Tc-99m sestamibi and a dual-detector, cadmium zinc telluride gamma camera. Positive findings on either modality were biopsied. High-risk and malignant biopsy findings were excised.ResultsIn 71 participants, 76 areas of calcifications were recommended for biopsy after mammography, and 24 (32%) were malignant, including 20 cases of ductal carcinoma in situ (DCIS) and 4 cases of invasive ductal cancer. Prebiopsy MBI was positive in 17 of the 76 (22%) calcifications, including 10 of 20 (50%) DCISs and 2 of 4 (50%) invasive cancers. The median pathologic size for MBI–positive cancers was 1.5 cm (range 0.5–3.2 cm) compared with 0.9 cm (range 0.1–2.0 cm) for MBI–negative cancers (P = 0.09).Non-mass uptake on MBI led to additional biopsies of 6 sites in 6 patients, and 2 of 6 (33%) MBI–detected incidental lesions showed malignancy; both DCIS contralateral to the mammographically detected calcifications. The overall per-lesion positive and negative predictive values of MBI in this prebiopsy setting were 61% (14 of 23) and 80% (47 of 59), respectively.ConclusionMolecular breast imaging has insufficient negative predictive value to identify calcifications in which biopsy could be avoided. However, among women presenting for biopsy of suspicious calcifications, MBI revealed additional sites of mammographically occult breast cancer.To avoid biopsy of suspicious calcifications on mammography, negative findings on MBI should not be used.
Dose Reduction in Molecular Breast Imaging With a New Image-Processing Algorithm

American Journal of Roentgenology | October 8, 2019 | Volume: 214 | Issue: 1 | Pages: 185-193

10.2214/ajr.19.21582 | PMID 31593516

Findings of CT-Derived Bone Strength Assessment in Inflammatory Bowel Disease Patients Undergoing CT Enterography in Clinical Practice

Inflammatory Bowel Diseases | November 26, 2018 | Volume: 25 | Issue: 6 | Pages: 1072-1079

10.1093/ibd/izy341 | PMID 30476314

Observer Performance with Varying Radiation Dose and Reconstruction Methods for Detection of Hepatic Metastases

Radiology | September 11, 2018 | Volume: 289 | Issue: 2 | Pages: 455-464

10.1148/radiol.2018180125 | PMID 30204077