Abstract 15321: Association Between Cardiovascular Risk Factors, Social Determinants of Health and Cardio-Ankle Vascular Index (CAVI) Scores Among African-American Adults: The FAITH! Heart Health+ (HH+) Study
Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available
Background Cardio-ankle vascular index (CAVI) is a measure of arterial stiffness associated with cardiovascular (CV) events and mortality. African American (AA) adults have a higher prevalence of CV risk factors (RFs) and adverse social determinants of health (SDOH) leading to a higher CV mortality risk than White adults. These disparities may be associated with arterial stiffness, however limited research exists on the association of CV RFs, SDOH, and CAVI among AAs. Hypotheses We hypothesized that CV RFs (eg, diabetes) and SDOH (eg, income) would be associated with CAVI among AA adults. Our secondary hypothesis was that AA adults would have a higher prevalence of abnormal CAVI scores (≥8.0) than White adults. Methods In the FAITH! HH+ study, CAVI measurements, CV RFs, and SDOH surveys were obtained. We collected CAVI readings and CV RFs from a secondary cohort of White adults (n=600), referred for echocardiography and without structural cardiac disease. The association of CV RFs, SDOH and CAVI scores among AAs was assessed via ANOVA and univariable linear regression. We compared CV RFs among both cohorts using Chi-squared tests and ANOVA, followed by comparing CAVI scores between cohorts using a multivariable linear regression model. Results In total, 48 AAs were included from the FAITH! HH+ cohort (mean age [SD]: 54.2 [11.5] years, 67.4% women). There was no significant association between CV RFs or SDOH with CAVI scores. In the 600 White adults assessed, mean age was 59.5 [14.7] years and 45.7% were women. Compared to White adults, AA participants had a lower burden of hyperlipidemia (43.5% vs 61.4%; p=0.017), but a higher burden of hypertension (73.9% vs 57.7%; p=0.031), diabetes (28.3% vs 9.3%; p<0.001), and obesity (71.7% obese vs 36.0%; p<0.001). There was no significant difference in CAVI scores between groups when adjusted for age, sex, and CV RFs (AA cohort: mean: 8.0 [1.4] vs White cohort: 8.4 [1.5]; p=0.790). Conclusions In this pilot study, SDOH and CV RFs were not associated with CAVI scores among AAs. There was no significant difference in CAVI scores between AA and White adults, despite a significantly higher burden of CV RFs in the AA cohort. Further studies are warranted to identify factors linked with onset and progression of arterial stiffness among AAs.
PPV of the Molecular Breast Imaging Lexicon
American Journal of Roentgenology | July 20, 2022 | Volume: 220 | Issue: 1 | Pages: 40-48
Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose–Reduced Multiphase Abdominal CT Examinations
American Journal of Roentgenology | June 22, 2022 | Volume: 220 | Issue: 1 | Pages: 73-85
Objective The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). Materials and Methods Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0–33, likely absent; 34–66, indeterminate; 67–100, likely present). Radiologists also rated confidence for the probability of UIP (0–20, normal; 21–40, inconsistent with UIP; 41–60, indeterminate UIP; 61–81; probable UIP; 81–100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. Results A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDIvol, 7.88 mGy) and research PCD-CT (median CTDIvol, 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings (P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507–0.818 vs 0.601–0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). Conclusions Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.
Impact of dual-energy 50-keV virtual monoenergetic images on radiologist confidence in detection of key imaging findings of small hepatocellular carcinomas using multiphase liver CT
Background Dual-energy virtual monoenergetic images can increase iodine signal, potentially increasing the conspicuity of hepatic masses. Purpose To determine if dual-energy 50-keV virtual monoenergetic images improve visualization of key imaging findings or diagnostic confidence for small (≤2 cm) hepatocellular carcinomas (HCC) at multiphase, contrast-enhanced liver computed tomography (CT). Material and Methods Patients with chronic liver disease underwent multiphase dual-energy CT imaging for HCC, with late arterial and delayed phase dual-energy 50-keV images reconstructed. Two non-reader subspecialized gastrointestinal (GI) radiologists established the reference standard, determining the location and diagnosis of all hepatic lesions using predetermined criteria. Three GI radiologists interpreted mixed kV CT images without or with dual-energy 50-keV images. Radiologists identified potential HCCs and rated their confidence (0–100 scales) in imaging findings of arterial enhancement, enhancing capsule, tumor washout, and LI-RADS 5 (2018) category. Results In total, 45 patients (14 women; mean age = 59.5 ± 10.9 years) with chronic liver disease were included. Of them, 19 patients had 25 HCCs ≤2 cm (mean size = 1.5 ± 0.4 cm). There were 17 LI-RADS 3 and 4 lesions and 19 benign lesions. Reader confidence in imaging findings of arterial enhancement, enhancing capsule, and non-peripheral washout significantly increased with dual-energy images ( P ≤ 0.022). Overall confidence in HCC diagnosis increased significantly with dual-energy 50-keV images (52.4 vs. 68.8; P = 0.001). Dual-energy images demonstrated a slight but significant decrease in overall image quality. Conclusion Radiologist confidence in key imaging features of small HCCs and confidence in imaging diagnosis increases with use of dual-energy 50-keV images at multiphase, contrast-enhanced liver CT.
Myocarditis Following Coronavirus Disease 2019 mRNA Vaccine: A Case Series and Incidence Rate Determination
Abstract Background Myocarditis following coronavirus disease 2019 (COVID-19) mRNA vaccines (Pfizer-BioNTech and Moderna) has been increasingly reported. Incidence rates in the general population are lacking, with pericarditis rather than myocarditis diagnostic codes being used to estimate background rates. This comparison is critical for balancing the risk of vaccination with the risk of no vaccination. Methods A retrospective case series was performed using the Mayo Clinic COVID-19 Vaccine Registry. We measured the incidence rate ratio (IRR) for myocarditis temporally related to COVID-19 mRNA vaccination compared with myocarditis in a comparable population from 2016 through 2020. Clinical characteristics and outcomes of the affected patients were collected. A total of 21 individuals were identified, but ultimately 7 patients met the inclusion criteria for vaccine-associated myocarditis. Results The overall IRR of COVID-19–related myocarditis was 4.18 (95% confidence interval [CI], 1.63–8.98), which was entirely attributable to an increased IRR among adult males (IRR, 6.69; 95% CI, 2.35–15.52) compared with females (IRR 1.41; 95% CI, .03–8.45). All cases occurred within 2 weeks of a dose of the COVID-19 mRNA vaccine, with the majority occurring within 3 days (range, 1–13) following the second dose (6 of 7 patients, 86%). Overall, cases were mild, and all patients survived. Conclusions Myocarditis is a rare adverse event associated with COVID-19 mRNA vaccines. It occurs in adult males with significantly higher incidence than in the background population. Recurrence of myocarditis after a subsequent mRNA vaccine dose is not known at this time.
Borderline Resectable and Locally Advanced Pancreatic Cancer: FDG PET/MRI and CT Tumor Metrics for Assessment of Pathologic Response to Neoadjuvant Therapy and Prediction of Survival
American Journal of Roentgenology | December 9, 2020 | Volume: 217 | Issue: 3 | Pages: 730-740