Citations 28

Three-Lobed Donor Left Lungs: Imaging and Clinical Implication in Thoracic Transplantation

Texas Heart Institute Journal | November 28, 2022 | Volume: 49 | Issue: 6 | Pages: No page available

10.14503/thij-22-7860 | PMID 36441543

Safe heart flush technique during recovery from donors after circulatory death

Journal of Cardiac Surgery | October 14, 2022 | Volume: 37 | Issue: 12 | Pages: 5646-5648

10.1111/jocs.17023 | PMID 36229938

Safe Heart Flush Technique During Recovery From Donors After Circulatory Death

No container title available | June 29, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.165648258.81499266/v1

For donation after circulatory death, procurement is performed after the heart has arrested. This technique has been employed and adopted by clinicians to overcome the shortage of available hearts for transplant. Warm ischemia time plays a pivotal role in the survival outcome of the heart recipients. We describe a fast and safe technique to flush the heart during recovery from circulatory death donors in order to shorten the warm ischemia time.
A Comparison of Negative Pressure and Conventional Therapy in Infected Open Chest Wounds

Surgical Infections | May 27, 2021 | Volume: 22 | Issue: 9 | Pages: 955-961

10.1089/sur.2020.397 | PMID 34042543

Heart–lung transplant in congenitally corrected transposition of the great arteries and dextrocardia patient

SAGE Open Medical Case Reports | February 12, 2021 | Volume: 9 | Issue: No issue available | Pages: No page available

10.1177/2050313x20987449 | PMID 33633862

A 53-year-old male patient was presented to our institution with the clinical picture of biventricular failure. The echocardiogram revealed congenitally corrected transposition of the great arteries, dextrocardia with situs solitus, atrioventricular discordance and ventriculoatrial discordance, severe systemic and mitral valves regurgitation, and severe pulmonary hypertension (mean pulmonary artery pressure: 51 mm Hg). He underwent heart–lung transplant. He was discharged on postoperative day 25 with left ventricular ejection fraction of 60%–65%, and with oxygen independency.
Pulmonary Langerhans Cell Histiocytosis Presenting as a Solitary Pulmonary Nodule on a Lung Cancer Screening CT

Case Reports in Pulmonology | December 29, 2020 | Volume: 2020 | Issue: No issue available | Pages: 1-4

10.1155/2020/8872111 | PMID 33425422

Pulmonary Langerhans cell histiocytosis (PLCH) is a rare inflammatory condition that mostly affects lungs in smokers. On imaging, it usually presents as multiple, upper lobe predominant, solid, and cavitary nodules, but presentation as solitary pulmonary nodule (SPN) is rare. We describe a case of SPN seen on low-dose lung cancer screening CT (LDCT) that was FDG avid on PET/CT. Given concern for malignancy, lobectomy was planned if intraoperative frozen section was consistent with malignancy. Lobectomy was performed based on frozen section; however, on formal pathology review, the nodule was ultimately found to be PLCH. This case illustrates an atypical presentation of PLCH as a solitary nodule. Furthermore, it helps demonstrate how rare etiologies (like PLCH) may be more frequently encountered and should be considered in the differential diagnosis for solitary lung nodules, especially in the era of lung cancer screening.
Agitation Techniques to Enhance Drainage of Retained Hemothorax

Surgical Innovation | December 18, 2020 | Volume: 28 | Issue: 5 | Pages: 544-551

10.1177/1553350620978002 | PMID 33339490

Background. Retained hemothorax (RH) is a common problem in cardiothoracic and trauma surgery. We aimed to determine the optimum agitation technique to enhance thrombus dissolution and drainage and to apply the technique to a porcine-retained hemothorax. Methods. Three agitation techniques were tested: flush irrigation, ultrasound, and vibration. We used the techniques in a benchtop model with tissue plasminogen activator (tPA) and pig hemothorax with tPA. We used the most promising technique vibration in a pig hemothorax without tPA. Statistics. We used 2-sample t tests for each comparison and Cohen d tests to calculate effect size (ES). Results. In the benchtop model, mean drainages in the agitation group and control group and the ES were flush irrigation, 42%, 28%, and 2.91 ( P = .10); ultrasound, 35%, 27%, and .76 ( P = .30); and vibration, 28%, 19%, and 1.14 ( P = .04). In the pig hemothorax with tPA, mean drainages and the ES of each agitation technique compared with control (58%) were flush irrigation, 80% and 1.14 ( P = .37); ultrasound, 80% and 2.11 ( P = .17); and vibration, 95% and 3.98 ( P = .06). In the pig hemothorax model without tPA, mean drainages of the vibration technique and control group were 50% and 43% (ES = .29; P = .65). Discussion. In vitro studies suggested flush irrigation had the greatest effect, whereas only vibration was significantly different vs the respective controls. In vivo with tPA, vibration showed promising but not statistically significant results. Results of in vivo experiments without tPA were negative. Conclusion. Agitation techniques, in combination with tPA, may enhance drainage of hemothorax.
The Radial Stapler Facilitates Lung-Conserving Wedge Resections

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | August 13, 2020 | Volume: 15 | Issue: 5 | Pages: 463-467

10.1177/1556984520942370 | PMID 32790513

Objective To test whether use of the radial stapler facilitates lung-conserving wedge resections compared to the linear stapler. Methods A video-assisted thoracoscopic simulation lab was established to compare wedge resections performed only with linear staplers to wedge resections performed with the option of a radial stapler. Preserved sheep lungs were used. The target was a 0.5 cm mark on an ovoid surface of the lung equidistant from all edges. Seven fully trained cardiothoracic surgeons participated. They were instructed to obtain at least a 1 cm margin in all directions from the mark. The surgeons were allowed to work from only 2 preassigned ports. Each resected specimen was weighed. The resection margin was the shortest distance measured from the edge of the mark to the staple line. The mass-to-margin ratio was defined as the mass of the specimen divided by the length of the margin. The results were analyzed using a t-test for 2 independent means. Results The 17 radial resections demonstrated a significantly better mass-to-margin ratio (3.31 [SD = 1.19]) compared to the 11 linear resections (4.75 [SD = 1.32], t[26] = 3, P = 0.006). Conclusions In a thoracoscopic simulation, the option of a radial stapler allowed for a better mass-to-margin resection of a small target from a broad surface of the lung than a linear stapler-only option.
Incidentally Discovered Cor Triatriatum Sinistrum Anomaly During Heart Transplant

No container title available | July 16, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159493172.23025358

Heart-Lung Transplant in Congenitally Corrected Transposition of the Great Arteries and Dextrocardia Patient

No container title available | July 16, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159493108.80223139

Background and aim of the study: Congenitally corrected transposition of the great arteries (cc-TGA) is a rare type of congenital heart disease and heart-lung transplant (HLTx) is the potential solution if the patient developed severe biventricular failure.. Aim of the study is to present a challenging case of cc-TGA with dextrocardia managed by HLTx. Methods: A 53-year-old male patient was presented to our institution with biventricular failure. The echocardiogram revealed cc-TGA, dextrocardia with situs solitus, atrioventricular discordance and ventriculoatrial discordance, severe systemic and sub-pulmonary atrioventricular valves regurgitation, and severe pulmonary hypertension. He underwent heart-lung transplant. Results: The patient was discharged on postoperative day 25 on room air with normal left ventricular ejection fraction. Conclusion: This case highlights the complexity of preoperative and intraoperative management of cc-TGA, and demonstrates the challenges which the surgeons and anesthesiologists may face during the procedure of HLTx.