Back to Authors

Helgeson, Scott A.

https://orcid.org/0000-0001-7590-2293

A5009613721 | I1330342723

Mayo Clinic

Pulmonary and Critical Care Medicine

Citations 67

1710: VASOPLEGIC SHOCK CAUSED BY SEVERE SYSTEMIC INFLAMMATORY RESPONSE SYNDROME REQUIRING INTERLEUKIN-6

Critical Care Medicine | December 18, 2019 | Volume: 48 | Issue: 1 | Pages: 830-830

10.1097/01.ccm.0000649140.69047.72

Safety of Bedside Percutaneous Tracheostomy in Liver Transplant Recipients

A44. CRITICAL CARE: ONE THOUSAND AND ONE NIGHTS - NON-PULMONARY CRITICAL CARE | August 26, 2019 | Volume: No volume available | Issue: No issue available | Pages: A1665-A1665

10.1164/ajrccm-conference.2019.199.1_meetingabstracts.a1665

Hyoscyamine for a Slow Ventricular Response During Atrial Fibrillation

Annals of Internal Medicine | May 20, 2019 | Volume: 170 | Issue: 10 | Pages: 735

10.7326/l19-0093 | PMID 31108527

Reducing Iatrogenic Pneumothoraces: Using Real-Time Ultrasound Guidance for Pleural Procedures

Critical Care Medicine | April 13, 2019 | Volume: 47 | Issue: 7 | Pages: 903-909

10.1097/ccm.0000000000003761 | PMID 30985389

Objectives: Awareness of the impact of bedside ultrasound to reduce iatrogenic pneumothoraces while performing bedside pleural procedures has increased but with little understanding in how ultrasound is used for these procedures. Design and Setting: We conducted a retrospective chart review at a tertiary referral center in the United States from January 1, 2014, to March 31, 2017. Our study assessed adverse effect rates between real-time ultrasound-guided and ultrasound-marked thoracenteses and thoracostomy tube placements. Patients: Three-hundred ninety-four ICU patients were included in this study. Measurements and Main Results: There was a significant difference in the rate of adverse effects between real-time ultrasound-guided (0.63% [95% CI, 0.11–3.4%]) and ultrasound-marked (6.89% [95% CI, 4.15–11.24%]; p ≤ 0.01) procedures. More specifically, the rate of pneumothoraces was different between the two procedures (0.63% [95% CI, 0.11–3.4%] vs 4.43% [95% CI, 2.35–8.21%]; p = 0.02). In patients mechanically ventilated, there was a significant difference in overall adverse effect rates between groups of ultrasound use ( p = 0.01). Conclusions: The use of real-time ultrasound guidance was associated with a lower rate of iatrogenic pneumothoraces.
A 32-year-old man with hypoxemia and bilateral upper-lobe predominant ground-glass infiltrates on chest imaging

Oxford Medical Case Reports | October 3, 2018 | Volume: 2018 | Issue: 10 | Pages: No page available

10.1093/omcr/omy072 | PMID 30302263

Hyoscyamine for a Slow Ventricular Response During Atrial Fibrillation

Annals of Internal Medicine | May 17, 2018 | Volume: 169 | Issue: 6 | Pages: 418-419

10.7326/l18-0037 | PMID 29799971

Comparison of Brain Natriuretic Peptide Levels to Simultaneously Obtained Right Heart Hemodynamics in Stable Outpatients with Pulmonary Arterial Hypertension

Diseases | May 3, 2018 | Volume: 6 | Issue: 2 | Pages: 33

10.3390/diseases6020033 | PMID 29723983

Pulmonary arterial hypertension (PAH) is a progressive disease that requires validated biomarkers of disease severity. While PAH is defined hemodynamically by right heart catheterization (RHC), brain natriuretic peptide (BNP) is recommended by guidelines to assess disease status. Retrospectively collected data in 138 group 1 PAH patients were examined for the correlation of BNP levels to simultaneously obtained right heart catheterization (RHC). Patients were mostly Caucasian women, with functional class III symptoms, mean BNP of 406 ± 443 pg/mL, and an average right atrial pressure (RAP) of 9.9 ± 5.7 mm Hg and mean pulmonary artery pressure (mPAP) of 47.3 ± 14.7 mm Hg. Significant correlation was demonstrated between BNP and RAP (p = 0.021) and mPAP (p = 0.003). Additional correlation was seen with right heart size on echocardiography: right atrial (RAE; p = 0.04) and right ventricular enlargement (p = 0.03). An increased BNP level was an independent predictor of mortality (p < 0.0001), along with RAP (p = 0.039) and RAE (p = 0.018). Simultaneous collection of BNP at the time of RHC confirmed the correlation of BNP with right heart hemodynamics. The current results reinforce the use of BNP level as a continuous variable to assess disease severity in group 1 PAH.