Citations 45

Contemporary Cementless Patellar Implant Survivorship: A Systematic Review and Meta-Analysis of 3,005 Patellae

The Journal of Knee Surgery | January 6, 2025 | Volume: 38 | Issue: 10 | Pages: 505-511

10.1055/a-2509-3442 | PMID 39761678

AbstractHistorically, cementless patellar implants were fraught with issues of fixation and polyethylene wear. However, contemporary cementless patellar implants incorporate modern technologies for implant design and offer the potential for improved biological fixation and longevity. As such, an evaluation of the performance of modern cementless patellae is needed. The purpose of this study was to perform a systematic review and meta-analysis of contemporary cementless patellar implants used during primary total knee arthroplasty (TKA), with a particular focus on aseptic loosening of the patellar component. A systematic review of the literature was performed from January 2000 to February 22, 2024. We included all peer-reviewed studies that reported the number of revisions in patients who had cementless patellae placed in 2000 or later during primary TKA. Reviews and case reports were excluded. Out of 639 studies, 13 were included with a total of 3,005 cementless patellae analyzed. The mean patient age was 64 years and the mean body mass index (BMI) was 31 kg/m2. Meta-analyses were performed to calculate the pooled revision rate per person-year of revision for aseptic loosening of the patellar component and revision for any patellar failure. Upon analysis of 13 studies involving a total of 3,005 cementless patellae, the revision rate for aseptic loosening of the patella was 0.2 per 1,000 person-years and the revision rate for any patellar failure was 1 per 1,000 person-years. Contemporary cementless patellar implants showed an overall revision rate of 1 per 1,000 person-years, demonstrating excellent longevity. The high survivorship, together with a low rate of loosening, show the utility and effectiveness of these implants. Given the nature of biologic fixation, these results are promising for long-term implant stability but additional follow-up is warranted.
Modular dual-mobility constructs outperformed large femoral heads in 299 revision total hip arthroplasties at mid-term follow-up

The Bone & Joint Journal | January 1, 2025 | Volume: 107-B | Issue: 1 | Pages: 58-64

10.1302/0301-620x.107b1.bjj-2024-0170.r1 | PMID 39743935

AimsThe purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications.MethodsWe identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).ResultsThe ten-year survival free of re-revision for dislocation was 99% (95% CI 95 to 100) in the MDM cohort and 91% (95% CI 84 to 96) in the LFH cohort, with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 7.1 (95% CI 1.3 to 40.8); p = 0.023). The ten-year survival free of any re-revision was 92% (95% CI 82 to 99%) in the MDM cohort and 84% (95% CI 74 to 90) in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.6 (95% CI 1.1 to 5.9); p = 0.024). The ten-year survival free of any dislocation was 95% (95% CI 85 to 99) in the MDM cohort and 87% (95% CI 78 to 92) in the LFH cohort with a significantly increased risk of any dislocation in the LFH cohort (HR 2.7 (95% CI 1.1 to 6.3); p = 0.028). There were no re-revisions or reoperations for metallosis or corrosion in the MDM cohort.ConclusionIn this head-to-head comparison, revision THAs with a MDM construct safely and effectively lowered the risk of re-revision for dislocation, any re-revision, and any dislocation compared to LFH at mid-term follow-up. There were no re-revisions or reoperations for metallosis or corrosion in the MDM cohort.Cite this article: Bone Joint J 2025;107-B(1):58–64.
Prospective Noninvasive Hemoglobin Monitoring in the Outpatient Total Joint Arthroplasty Setting

Journal of Bone and Joint Surgery | December 20, 2024 | Volume: 107 | Issue: 4 | Pages: 364-371

10.2106/jbjs.24.00438 | PMID 39705371

Background: Total joint arthroplasty (TJA) is increasingly being performed as an outpatient (i.e., same-day discharge) procedure. Postoperatively, orthostatic hypotension or pain-related tachycardia can lead to concerns regarding the hemoglobin (Hgb) level of the patient prior to discharge. The purpose of this study was to prospectively assess the reliability and accuracy of, and patient and nurse satisfaction with, postoperative noninvasive hemoglobin (nHgb) monitoring compared with an invasive serum hemoglobin (iHgb) laboratory draw in the outpatient TJA setting. Methods: We prospectively enrolled 200 patients undergoing outpatient unilateral TJA, of whom 157 were ultimately included in our analysis (94 hips, 63 knees). Postoperatively, both nHgb and iHgb values were obtained at a mean of 36 minutes apart. Surveys were completed by patients and nurses. The strength of the agreement between the 2 Hgb monitoring methods was evaluated with use of the Bland-Altman 95% limits of agreement, concordance correlation coefficient (CCC), and intraclass correlation coefficient (ICC). Receiver operating characteristic curve analyses were performed to investigate the ability of nHgb monitoring to predict an iHgb of <11.2 g/dL (the 5th-percentile iHgb value). Results: The mean preoperative iHgb was 14.2 ± 1.1 g/dL. The mean postoperative iHgb and nHgb values were 13.3 ± 1.5 and 13.3 ± 1.2 g/dL, respectively. The Bland-Altman 95% limits of agreement were −3.2 and +3.1 g/dL, indicating that 95% of patients’ iHgb values are expected to fall between these limits relative to the nHgb value of the patient. The CCC and ICC were both 0.33. An nHgb cutoff value of <12.7 g/dL had 100% sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Patients reported less pain with the nHgb test than with the iHgb test (mean pain score, 0.0 versus 1.8; p < 0.001), and 97% of patients preferred the nHgb test. Following the nHgb test, 73% of responding patients and 83% of responding nurses were “somewhat more reassured” to “significantly more reassured” about same-day discharge. Conclusions: Routine nHgb testing can rapidly screen patients undergoing outpatient TJA for acute anemia prior to discharge. With an nHgb of <12.7 g/dL, there was perfect sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Most patients and nurses felt more reassured about same-day discharge after nHgb monitoring. Level of Evidence: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.
Early adverse outcomes remain challenging to prevent in morbidly obese patients undergoing total hip arthroplasty

The Bone & Joint Journal | November 1, 2024 | Volume: 106-B | Issue: 11 | Pages: 1223-1230

10.1302/0301-620x.106b11.bjj-2023-1187.r1 | PMID 39481442

AimsThe prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following total hip arthroplasty (THA). We sought to evaluate trends in BMI and complication rates of obese patients undergoing primary THA over the last 30 years.MethodsThrough our institutional total joint registry, we identified 15,455 primary THAs performed for osteoarthritis from 1990 to 2019. Patients were categorized according to the World Health Organization (WHO) obesity classification and groups were trended over time. Cox proportional hazards regression analysis controlling for confounders was used to investigate the association between year of surgery and two-year risk of any reoperation, any revision, dislocation, periprosthetic joint infection (PJI), venous thromboembolism (VTE), and periprosthetic fracture. Regression was stratified by three separate groups: non-obese; WHO Class I and Class II (BMI 30 to 39 kg/m2); and WHO Class III patients (BMI ≥ 40 kg/m2).ResultsThere was a significant increase in the proportion of all obesity classes from 1990 to 2019, and the BMI values within each WHO class significantly increased over time. Risk of any reoperation did not change over time among non-obese or WHO Class I/II patients, but increased for WHO Class III patients (hazard ratio (HR) 1.04; p = 0.044). Risk of dislocation decreased over time for non-obese (HR 0.96; p < 0.001) and WHO Class I/II (HR 0.96; p = 0.002) patients, but did not change over time for WHO Class III (HR 0.94; p = 0.073) patients. Risks of any revision and PJI did not change over time for any group.ConclusionThe proportion of patients undergoing THA who are obese has increased dramatically at our institution between 1990 and 2019. Despite BMI values increasing within all WHO classes over time, two-year complication risks have remained stable or decreased in WHO Class I/II patients. However, continued efforts will be required to mitigate risks in the heaviest WHO Class III patients.Cite this article: Bone Joint J 2024;106-B(11):1223–1230.
Outcomes of Obese Patients Undergoing Primary Total Knee Arthroplasty

Journal of Bone and Joint Surgery | September 24, 2024 | Volume: 106 | Issue: 21 | Pages: 1963-1970

10.2106/jbjs.23.01413 | PMID 39316660

Background: The rates of obesity among patients undergoing total knee arthroplasty (TKA) have substantially increased. In addition, obesity is a well-established risk factor for complications after TKA. The purpose of this study was to analyze trends in body mass index (BMI) and complication risk among obese patients undergoing primary TKA treated at a single institution over 3 decades. Methods: Utilizing an institutional total joint registry, 13,919 primary TKAs performed to treat osteoarthritis between 1990 and 2019 were identified. Patients were stratified by BMI according to the World Health Organization (WHO) classification into 3 groups: non-obese (BMI, <30 kg/m 2 ), WHO Class-I and II obese (BMI, 30 to 39.9 kg/m 2 ), and WHO Class-III obese (BMI, ≥40 kg/m 2 ). Trends in BMI and survivorship free from reoperation, revision, and periprosthetic joint infection (PJI) were analyzed over time while controlling for age, sex, and the Charlson Comorbidity Index. Results: Over the study period, there was a 90% increase in the prevalence of Class-II obesity (13% to 25%) and a 300% increase in Class-III obesity (3% to 12%). Analysis of the entire cohort demonstrated a decrease in the 2-year risk of any reoperation, any revision, and PJI (p < 0.05 for all) with time. The risk decreased significantly over time for non-obese patients for any reoperation (p = 0.029) and any revision (p = 0.004) and for Class-III obese patients for any reoperation (p = 0.038) and any revision (p = 0.012), but it remained stable for Class-I and II obese patients. The risk of PJI decreased from 1990 to 2019 for non-obese patients (p = 0.005), but there were no significant changes in PJI risk for any obesity group. Conclusions: Despite increasing rates of obesity among our patients who underwent TKA, we observed decreasing risks of reoperation, revision, and PJI over time. The risks of reoperation and revision declined among non-obese patients, remained stable for Class-I and II obese patients, and declined for Class-III obese patients. The PJI risk declined for non-obese patients over the study period, but no such decline occurred for any category of obesity. Despite the decreasing risks of reoperation and revision, further work is needed to improve PJI risk in obese patients. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
3D-Printed Metaphyseal Cones in Revision Total Knee Arthroplasties

Journal of Bone and Joint Surgery | June 14, 2024 | Volume: 106 | Issue: 18 | Pages: 1688-1696

10.2106/jbjs.23.01196 | PMID 38875316

Background: Porous metaphyseal cones are frequently utilized during revision total knee arthroplasty (TKA) procedures. The purpose of the present study was to evaluate 3D-printed metaphyseal cones used for revision TKA, with specific emphasis on implant survivorship, radiographic appearance, and clinical outcomes after short-term follow-up. Methods: We identified 740 cones (498 tibial, 242 femoral) that had been inserted during 533 revision TKA procedures that had been performed at a single tertiary care academic institution. Aseptic loosening (n = 199), periprosthetic joint infection (PJI) (n = 183), and instability (n = 84) were the most common reasons for the index revision. Type-2B or 3 bone loss was present in 67% of the knees. The mean age was 66 years, the mean body mass index was 34 kg/m 2 , and 55% of the patients were female. Serial radiographs were reviewed. The mean duration of follow-up was 4 years. Results: The 5-year cumulative incidence of cone revision for aseptic loosening was 1% (95% confidence interval [CI], 0% to 3%). The 5-year cumulative incidence of any cone revision or removal was 6% (95% CI, 4% to 9%). In total, 37 cones (19 femoral, 18 tibial) were revised, with PJI (n = 23; 14 recurrent), periprosthetic femoral fracture (n = 3), arthrofibrosis (n = 3), and aseptic loosening of the femoral component and femoral cone (n = 3) as the most common reasons for cone revision. The 5-year cumulative incidence of any TKA re-revision was 14% (95% CI, 11% to 18%). There were a total of 67 re-revisions, with PJI (n = 38), persistent drainage (n = 6), and extensor mechanism disruption (n = 3) being the most common reasons. Radiographically, 2 unrevised femoral cones and 1 unrevised tibial cone appeared to be possibly loose; all 3 cones were in knees with distal femoral replacements or hinged constructs. Conclusions: This large series showed that 3D-printed titanium metaphyseal cones were very durable at short-term follow-up, with a 5-year cumulative incidence of cone revision for aseptic loosening of 1%. PJI was the most common reason for cone revision and any revision. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Duration of cefazolin prophylaxis did not impact infection risk in a murine model of joint arthroplasty

Journal of Orthopaedic Research | May 26, 2024 | Volume: 42 | Issue: 10 | Pages: 2345-2352

10.1002/jor.25903 | PMID 38796743

AbstractTo minimize periprosthetic joint infection (PJI) risk, some clinicians prescribe extended antibiotic prophylaxis (EAP) following total joint arthroplasty (TJA). Given the limited evidence supporting EAP, we sought to evaluate impact of prophylactic antibiotic duration on PJI risk in a murine TJA model. A titanium prosthesis was implanted into the proximal tibia of 89 mice and inoculated with 102 colony forming units (cfu) of Staphylococcus aureus Xen36. Control mice (n = 20) did not receive antibiotics. Treated mice received either 24 h (n = 35) or 4 days (n = 34) of cefazolin prophylaxis. Cultures were obtained from the prostheses, tibia, femur, and knee tissues 3 weeks after surgery. All mice in the control group developed PJI. Both prophylaxis regimens reduced the rate of PJI relative to the control, with only 2/35 mice in the 24‐h cohort (p < 0.0001) and 1/34 in 4‐day cohort developing PJI (p < 0.0001). CFU counts from the prostheses, bone and knee tissues were reduced for the 24‐h and 4‐day prophylaxis cohorts relative to the control (p < 0.0001 for both). There was no difference in rates of PJI or CFU counts between the two prophylaxis cohorts (p = 0.58). Prophylactic cefazolin profoundly reduced rates of PJI in a murine model of TJA in which all control animals developed PJI. Extending cefazolin prophylaxis duration from 24 h to 4 days did not result in improved PJI rates or decreased bacterial loads in infected cases. While these results strongly support use of antibiotic prophylaxis for TJA, EAP did not appear to add benefit in the described mouse model.
Diaphyseal Impaction Grafting Combined with Metaphyseal Cones

Journal of Bone and Joint Surgery | May 1, 2024 | Volume: 106 | Issue: 14 | Pages: 1293-1299

10.2106/jbjs.23.01085 | PMID 38691581

Background: Metaphyseal cones with cemented stems can be successfully utilized in most revision total knee arthroplasties (TKAs). However, if the diaphysis has been previously violated, fixation of the cemented stem, which is important for cone ingrowth and construct survival, can be compromised. The initial results of our novel technique combining diaphyseal impaction bone-grafting with a metaphyseal cone were promising but required additional study. The purpose of the present study was to assess results of this technique in a larger cohort. Methods: A metaphyseal cone combined with diaphyseal impaction grafting and a cemented stem was utilized in 88 revision TKAs at our institution, including 35 from our prior study. The mean age at the time of revision was 67 years, and 67% of patients were male. Patients had had a mean of 4 prior knee arthroplasty procedures. The 2 most common reasons for revision were aseptic loosening (78%) and 2-stage reimplantation for periprosthetic joint infection (PJI) (19%). The mean follow-up was 4 years. Results: At the time of the latest follow-up, no cone-impaction grafting constructs required re-revision for aseptic loosening. Five-year survivorship free from any revision of the cone-impaction grafting construct and free from any reoperation was 95% and 65%, respectively. A total of 25 knees (28%) underwent reoperation, with the 2 most common indications being PJI and periprosthetic fracture. All cones were osseointegrated, and all bone graft appeared stable or incorporated. One patient had radiographic evidence of tibial component loosening despite a well-fixed cone; however, this patient was asymptomatic and had not undergone revision at 9 years. Conclusions: When presented with a sclerotic, polished diaphyseal canal with deficient cancellous bone and concomitant metaphyseal bone loss, our technique of combining diaphyseal impaction grafting with a metaphyseal cone proved extremely durable in this larger series of patients. No cone-impaction grafting constructs required re-revision for aseptic loosening. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Contemporary Aseptic Revision Total Hip Arthroplasty in Patients ≤50 Years of Age

Journal of Bone and Joint Surgery | April 30, 2024 | Volume: 106 | Issue: 12 | Pages: 1108-1116

10.2106/jbjs.23.01467 | PMID 38687829

Background: There has been a paucity of long-term outcomes data on aseptic revision total hip arthroplasties (THAs) in the young adult population. The purpose of this study was to evaluate implant survivorship, complications, and clinical outcomes in a large cohort of contemporary aseptic revision THAs in patients ≤50 years of age at the time of the surgical procedure. Methods: We identified 545 aseptic revision THAs performed at a single academic institution from 2000 to 2020 in patients who were 18 to 50 years of age. Patients who underwent conversion THAs and patients with a history of any ipsilateral hip infection were excluded. The mean age was 43 years, the mean body mass index (BMI) was 29 kg/m 2 , and 63% were female. The index indication for revision THA was aseptic loosening in 46% of cases, polyethylene wear or osteolysis in 28% of cases (all revisions of conventional polyethylene), and dislocation in 11% of cases. There were 126 hips (23%) that had undergone at least 1 previous revision (median, 1 revision [range, 1 to 5 revisions]). The mean follow-up was 10 years. Results: In the entire cohort, the 20-year survivorship free of any re-revision was 76% (95% confidence interval [95% CI], 69% to 82%). There were 87 re-revisions, with 31 dislocations, 18 cases of aseptic loosening of the femoral component, and 16 periprosthetic joint infections (PJIs) being the most common reasons for re-revision. Dislocation as the indication for the index revision was associated with an increased risk of re-revision (hazard ratio, 2.9; p < 0.001). The 20-year survivorship free of any reoperation was 73% (95% CI, 66% to 78%). There were 75 nonoperative complications (14%), including 32 dislocations. The mean Harris hip score significantly improved (p < 0.001) from 65 preoperatively to 81 at 10 years postoperatively. Conclusions: Contemporary aseptic revision THAs in patients ≤50 years of age demonstrated a re-revision risk of approximately 1 in 4 at 20 years. Dislocation, aseptic loosening of the femoral component, and PJI were the most common reasons for re-revision. Index revision THAs for dislocation had a 3 times higher risk of re-revision. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Cemented dual-mobility constructs in uncemented revision acetabular components

The Bone & Joint Journal | April 1, 2024 | Volume: 106-B | Issue: 4 | Pages: 352-358

10.1302/0301-620x.106b4.bjj-2023-1061.r1 | PMID 38555941

AimsDislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.MethodsWe identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).ResultsThere were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case.ConclusionWhile dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface.Cite this article: Bone Joint J 2024;106-B(4):352–358.