Citations 16

Left Ventricular Hemodynamics Before and 1 Year After Internal Mammary Artery Implantation in Patients with Coronary Artery Disease and Angina Pectoris

Circulation | June 11, 2012 | Volume: 42 | Issue: 3 | Pages: 471-477

10.1161/01.cir.42.3.471 | PMID 5451232

Left ventricular hemodynamics at rest and during supine exercise were studied before and 1 year after internal mammary artery implantation in 24 patients with severe coronary artery disease and angina pectoris and in five similar patients before and after 1 year of medical treatment. In the surgical group, 14 had evidence of one or more implants providing collaterals to coronary arteries, and 10 had no evidence of collaterals from the implant. Only two patients, both with functioning implants, showed a return to normal of left ventricular end-diastolic pressure at rest and during exercise. There was no correlation between clinical improvement and hemodynamics at the time of the postoperative study. It is concluded that left ventricular hemodynamics may return to normal after internal mammary artery implantation but this was uncommon in the present study.
Pregnancy and Open-Heart Surgery

Circulation | June 11, 2012 | Volume: 39 | Issue: 5s1 | Pages: No page available

10.1161/01.cir.39.5s1.i-257 | PMID 5792982

During pregnancy, when surgically reparable heart disease can no longer be medically manged, open- or closed-heart surgery is the procedure of choice without prior therapeutic abortion. Cyanotic congenital heart disease in a pregnant patient when completely correctable surgically may be an indication for surgery in itself. Available data suggest that pregnancy per se does not increase the maternal risk of heart surgery with use of extracorporeal circulation. Fetal mortality in our series was 33%.
Complete Repair of Transposition of the Great Arteries with Pulmonary Stenosis

Circulation | June 11, 2012 | Volume: 39 | Issue: 1 | Pages: 83-95

10.1161/01.cir.39.1.83 | PMID 5782810

Complete surgical correction of transposition of the great arteries associated with subvalvular pulmonary stenosis carries a high mortality rate. A new surgical technique that achieves redirection of the ventricular outflows and relieves pulmonary stenosis by bypassing it, was successfully used to repair complete transposition of the great arteries associated with ventricular septal defect (VSD) and valvular and subvalvular pulmonary stenosis in a 14½-year-old patient. The repair consists of (1) division of the pulmonary artery, the cardiac end of which is oversewn, (2) repair of the VSD with a patch in such a way as to connect the left ventricle with the aorta, and (3) reconstruction of the pulmonary artery with an aortic homograft, including the aortic valve, which is anastomosed between the distal end of the pulmonary artery and the right ventricle. A review of the cases in which the current techniques were used indicates that the location and nature of the obstruction in the left ventricular outflow tract defies successful repair in most instances. Localized ridges and diffuse hypoplastic outflow tracts are recognized causes of obstruction, but anomalies of the mitral valve commonly contribute to or are the primary cause of subvalvular obstruction.
Left Ventricular Performance During Mild Supine Leg Exercise in Coronary Artery Disease

Circulation | June 11, 2012 | Volume: 37 | Issue: 6 | Pages: 922-931

10.1161/01.cir.37.6.922 | PMID 4968176

Left ventricular (LV) performance was studied during mild exercise (100 kg-m/min for 3 minutes) in 19 cases of coronary artery disease (CAD). Each patient suffered from a severe anginal syndrome. None had ventricular aneurysm, cardiomegaly, or clinical heart failure. Mean resting values follow: LV end-diastolic pressure (LVEDP), 19 ± 7 mm Hg; LV systolic pressure (LVSP), 150 ± 16 mm Hg; stroke volume index (SVI), 48 ± 10 ml/beat/m 2 ; and LV stroke work index (LVSWI), 81 ± 19 g-m/m 2 . During exercise LVEDP rose to 30 ± 8 mm Hg ( P ≤0.001) and LVS to 160 ± 20 (not significant [NS]); SVI diminished to 46 ± 11 (NS) and LVSWI, to 76 ± 24 (NS). Patients with decreased or asynchronous areas of LV myocardium identified on cine left ventriculograms had higher mean LVEDPs during exercise than did those with normal ventriculograms (34 ± 10 versus 26 ± 4 mm Hg; P ≤0.05). The difference between responses to exercise of patients who experienced angina during the study and of those who did not was NS. Administration of nitroglycerin reduced the increase in LVEDP during exercise. An abnormality in LV performance-a significant rise in LVEDP without a significant increase in SVI or LVSWI-was observed in 13 of 19 cases of CAD.
Late Results of Cardiac-Valve Replacement

Circulation | June 11, 2012 | Volume: 37 | Issue: 4s2 | Pages: No page available

10.1161/01.cir.37.4s2.ii-75 | PMID 5646591

Ultrasonic and computed tomographic imaging of the abdominal aorta

World Journal of Surgery | May 11, 2006 | Volume: 4 | Issue: 5 | Pages: 511-518

10.1007/bf02401617 | PMID 6894508

AbstractAlthough ultrasonic and computed tomographic technology is continuing to evolve, these already sophisticated imaging tests have become the primary methods of evaluating the patients with aortic aneurysms. Both modalities are accurate and noninvasive. The major value of these techniques to the surgeon is in assessing those patients in whom the diagnosis is in doubt and in following patients in whom it has been elected to observe a small stable aneurysm. Changes in an aneurysm can be detected on serial examinations which might indicate the need for surgery in spite of adverse patient risk factors, and these techniques may provide a means of detecting false aneurysms in patients who are difficult to assess accurately by physical examination. Ultrasound and computed tomography are very helpful techniques in the diagnosis and assessment of aortic aneurysms. These diagnostic modalities are not required in every patient and should be used discriminately and when indicated.