Back to Authors

Hassan, Ameer E

https://orcid.org/0000-0002-7148-7616

A5079146238 | I2802326326

Mayo Clinic

The University of Texas Rio Grande Valley

Citations 29

Associated Risks to the Treatment of Unruptured Intracranial Aneurysms (MARTA) Score: Development and External Validation

Neurosurgery | January 14, 2026 | Volume: 99 | Issue: 3 | Pages: 603-614

10.1227/neu.0000000000003900 | PMID 41532751

BACKGROUND AND OBJECTIVES: Unruptured intracranial aneurysms (UIAs) are increasingly detected and require careful management to prevent rupture. No externally validated score currently predicts procedural risk to guide treatment decisions. We developed and validated 2 predictive scores for complications after endovascular treatment (EVT) or neurosurgical treatment (NT) of UIA using routinely collected clinical and aneurysmal features. METHODS: We conducted a multicenter retrospective study including patients with UIA treated with EVT or NT across 15 neurovascular centers (2014-2024). Predictive models were built using multivariable logistic regression, with variables derived from Delphi consensus. The primary outcome was a composite safety end point: new neurological deficits, modified Rankin Scale (mRS) worsening (≥1 point or mRS 2-5 within 30 days), or procedural death. Internal validation used bootstrapping, and external validation was performed temporally and institutionally. Model performance was assessed using area under the receiver operating characteristic curve (AUROC) and calibration. Final scores, named Morbidity and Mortality Associated Risk in the Treatment of UIAs (MARTA)-EVT and MARTA-NT, were compared with existing models identified through systematic review. RESULTS: Among 2647 patients (1907 EVT and 740 NT), procedural complications occurred in 6.3% (EVT) and 12.8% (NT). Independent predictors included age, baseline mRS, aneurysm location, size, morphology, and procedural factors. MARTA-EVT (AUROC = 0.68, 95% CI = 0.57-0.78) and MARTA-NT (AUROC = 0.65, 95% CI = 0.54-0.77) showed moderate discrimination and good calibration. MARTA-EVT outperformed existing models; MARTA-NT performed similarly to SAFETEA. Predictive models are available open-source: https://martascoreapp.shinyapps.io/martascoreapp/. CONCLUSION: MARTA-EVT and MARTA-NT are validated tools for predicting procedural risks in UIA treatment and may support patient counseling and clinical decision making.
Customer discovery in neurointervention: a practical primer for identifying unmet needs

Journal of NeuroInterventional Surgery | December 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: jnis-2025-024474

10.1136/jnis-2025-024474 | PMID 41339076

Background Advancement in neurointervention is frequently driven by the introduction of new technology and devices that improve procedural efficacy and patient outcomes. For physician-innovators, customer discovery—or the process of directly engaging with end users to explore workflows and associated challenges—offers a structured way to identify meaningful problems and guide early innovation. This primer aims to outline stepwise guidance for conducting customer discovery within neurointervention to characterize key areas of unmet need. Methods We detail stepwise guidance for conducting customer discovery founded on foundational business literature. To illustrate this process, we conducted five interviews with expert neurointerventionalists engaged in clinical innovation. Interview transcripts were reviewed and analyzed to track emerging themes, and responses were synthesized into a neurointerventionalist customer profile. Results Responses from interviewed neurointerventionalists suggested that safer vascular access, tools to support treatment prognostication, and condition-specific device design are unmet areas of need. Moreover, interviews revealed broader concerns about stagnation in device innovation and barriers within regulatory and institutional pathways. Conclusions Structured customer discovery identifies unmet needs that may be overlooked when device development is solely driven by technical breakthroughs or published outcomes. By outlining an actionable framework for customer discovery in neurointervention, we provide a practical model for aligning future innovation with real-world clinical challenges.
Predictive modeling of long-term improvement in occlusion outcomes following Woven EndoBridge treatment of cerebral aneurysms: A machine learning approach

Interventional Neuroradiology | November 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251391915 | PMID 41182964

Background The Woven EndoBridge (WEB) device represents an innovative solution for cerebral aneurysm occlusion, particularly for challenging wide-neck bifurcation aneurysms. However, factors affecting sustained occlusion remain poorly understood. We utilized machine learning to attempt to identify predictors of favorable long-term outcomes following WEB treatment. Methods In this multicenter retrospective study, we collected patient demographics, aneurysm characteristics, procedural details, and clinical outcomes. The primary endpoint was improvement in occlusion status, defined as maintained Raymond-Roy Occlusion Classification (RROC) grade 1, or improvement from grade 2 to 1, or from grade 3 to either 2 or 1 on final angiographic follow up. The dataset was split into training (75%) and validation (25%) sets. The CatBoost algorithm was selected based on performance metrics, with Shapley Additive exPlanations (SHAP) values calculated to determine feature importance. Furthermore, a multivariable binomial logistic regression model was performed to validate machine learning findings. Results Among 720 aneurysms from 36 hospitals, 84% showed improvement in occlusion at follow up. Both machine learning and multivariable logistic regression identified aneurysm height as the most consistent correlate of nonimprovement (odds ratio (OR) 0.90 per mm, p = 0.022). In the CatBoost model, the highest-ranking features by SHAP included aneurysm height, patient age, treatment acuity, ACom location, WEB-SLS device, bifurcation anatomy, aneurysm multiplicity, baseline modified Rankin Scale, access route, and partial thrombosis. Conclusions Machine-learning and regression analyses identified consistent predictors of occlusion improvement after WEB treatment, with aneurysm height most strongly linked to nonimprovement. These insights may guide patient selection and follow up. Findings require cautious interpretation and external validation in larger cohorts.
Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry

Journal of NeuroInterventional Surgery | April 30, 2025 | Volume: 18 | Issue: 3 | Pages: 782-789

10.1136/jnis-2024-022628 | PMID 40306928

Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (P<0.001 for both maximal diameter and neck ratio). At the final follow-up, partially thrombosed aneurysms treated by the WEB device had a 38.5% retreatment rate, compared with 7.0% for non-thrombosed aneurysms (P<0.001). Among partially thrombosed aneurysms, the Raymond-Roy type IIIa/b occlusion rate was higher (38.5% vs 9.9%, P<0.001). On multivariate analysis, partially thrombosed aneurysms compared with non-thrombosed aneurysms had an increased rate of retreatment (OR 3.64, 95% CI 1.28 to 10.1). Conclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
Multicenter analysis of flow diversion for recurrent/persistent intracranial aneurysms after stent-assisted coiling

Journal of NeuroInterventional Surgery | March 27, 2025 | Volume: 18 | Issue: 2 | Pages: 324-331

10.1136/jnis-2024-022422 | PMID 40139781

Background Flow-diverter stents (FDS) have become the standard of care for a wide range of intracranial aneurysms, but their efficacy/safety in the context of recurrent/recanalized aneurysms following stent-assisted coiling (SAC) is not well established. We evaluate the outcomes of FDS retreatment in a large multicenter cohort. Methods We retrospectively analyzed data from 118 patients across 22 institutions who underwent FDS retreatment for recurrent/persistent aneurysms after SAC (2008–22). The primary outcome was angiographic occlusion status at last follow-up, categorized as complete (100%), near-complete (90–99%), or incomplete (<90%) occlusion. Secondary outcomes included procedural complications and clinical outcomes measured by the modified Rankin Scale (mRS). Results A total of 118 patients (median age 57, 74.6% female) with median follow-up of 15.3 months were identified. Complete occlusion was achieved in 62.5% and near-complete occlusion in 25%. FDS deployment within the pre-existing stent was successful in 98.3% of cases. Major complications occurred in 3.4% of cases, including postoperative aneurysmal rupture with resultant mortality (1.6%) and thromboembolic events with long-term disability (1.6%). Favorable clinical outcomes (mRS 0–2) were observed in 95.1% of patients. Wider aneurysm neck diameter was a significant predictor of incomplete occlusion (adjusted OR (aOR) 1.23 per mm, P=0.044), with male sex trending towards association with non-occlusion (aOR 3.2, P=0.07), while baseline hypertension was associated with complete occlusion (aOR 0.32, P=0.048). Conclusions FDS treatment for recurrent/residual aneurysms after SAC represents a viable treatment option for these challenging cases with acceptable safety and reasonable occlusion rates, although lower than de novo FDS occlusion rates.
Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study

Journal of Neurosurgery | January 31, 2025 | Volume: 142 | Issue: 6 | Pages: 1732-1740

10.3171/2024.10.jns241058 | PMID 39889291

OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
Macrowire for intracranial thrombectomy: An early experience of a new device and technique for anterior circulation large vessel occlusion stroke

Interventional Neuroradiology | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199241308328 | PMID 39692535

Background and Purpose Mechanical thrombectomy (MT) has become the standard of care for treatment of acute ischemic stroke secondary to large vessel occlusion up to 24 h from the last known normal time. With ADAPT and SOLUMBRA techniques, classically, a large bore aspiration catheter is delivered over a microcatheter and microwire crossing the clot to perform thrombectomy. Recently, a novel macrowire (Colossus 035 in.) has been introduced as a potential alternative to the use of microwire-microcatheter to allow the delivery of the aspiration catheter (ID = 0.070 in. up to 0.088 in.) over a macrowire alone. Objective To test the feasibility of delivering an aspiration catheter to clot interface over a macrowire alone. Materials and Methods A retrospective evaluation of prospectively maintained Macrowire for Intracranial Thrombectomy (MINT) Registry where this novel technique was utilized for thrombectomy. Consecutive patients undergoing MT using the MINT technique were included. We collected baseline demographics, imaging and clinical characteristics, rate of procedural success, conversion to traditional MT, and complications. Results Fifty consecutive patients were recruited during the initial 4 months of the larger study duration. The aspiration catheter was able to be advanced to the clot interface successfully in 46/50 (92%) using the MINT technique. Median time from vascular access to the first pass was 11.30 min (IQR = 7.45–14.30 min) and successful thrombectomy was 14 min (IQR = 10–22.15). The modified first-pass effect with this procedure was 71%. One vasospasm was reported as a procedural complication. Conclusions MINT is safe and feasible for large vessel occlusion recanalization based on our initial clinical experience in this multicenter study.
Defining ideal middle cerebral artery bifurcation aneurysm size for Woven EndoBridge embolization

Journal of Neurosurgery | October 12, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-11

10.3171/2024.5.jns232204 | PMID 39393093

OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.
Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms—A retrospective analysis of the WorldWide WEB Consortium database

Interventional Neuroradiology | August 10, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199241267320 | PMID 39127463

Background Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond–Roy classification 1 or 2) remains challenging. Objective Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. Methods We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. Results A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535–0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024–0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer–Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/ . Conclusion The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.
MINT Registry: Rationale and Study Design

Stroke: Vascular and Interventional Neurology | July 7, 2024 | Volume: 4 | Issue: 5 | Pages: No page available

10.1161/svin.124.001384 | PMID 41586276

Background Mechanical thrombectomy has become the standard of care for treatment of acute ischemic stroke secondary to large‐vessel occlusion up to 24 hours from last known normal time. Multiple different techniques for mechanical thrombectomy have been described, including a direct aspiration first‐pass technique and stent retriever thrombectomy. With a direct aspiration first‐pass technique, classically, a large‐bore aspiration catheter is delivered over a microcatheter and microwire to the clot. Recently, a novel macrowire has been introduced as a potential alternative to the use of microwire–microcatheter to allow the delivery of the aspiration catheter. The aim of this study is to develop a multicenter registry comparing delivery of an aspiration catheter for intracranial thrombectomy for acute ischemic stroke secondary to emergent large‐vessel occlusion over a macrowire in comparison with traditional use of microcatheter and microwire. Methods MINT (Macrowire for Intracranial Thrombectomy) is a multicenter, observational study currently enrolling patients with large‐vessel occlusion who underwent mechanical thrombectomy using a macrowire to deliver the aspiration catheter to the intracranial occlusion. All the participating sites will screen and report cases on a monthly basis. The decision to use the macrowire and various aspiration catheters is at the discretion of the interventionalist. Results We will collect patient's clinical, demographic, and radiographic data. In addition, we plan to collect procedure variables and postprocedure clinical and imaging data. Outcomes include successful delivery of the reperfusion catheter to the clot interface, time taken from groin access to first pass, and a bailout strategy for thrombectomy in cases where this is not feasible. Conclusion The MINT registry will add to our understanding of safety and efficacy of this novel macrowire in intracranial thrombectomy. This registry will also highlight and allow for understanding in workflow improvements from simplifying setup and possibly cost effectiveness of this technique.