Citations 25

Distal Access to Wide-Necked Aneurysms—‘Around the World’ Technique: 2-Dimensional Operative Video

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E39-E40

10.1093/ons/opaa369 | PMID 33316816

Abstract Wide-necked aneurysms often pose challenges for distal access to the distal vasculature. This 64-yr-old woman without neurological deficits presented with atypical headaches of gradual onset. MRI revealed a large, symptomatic, unruptured carotid terminus aneurysm incorporating the origin of both the middle (MCA) and anterior cerebral arteries (ACA). Its wide neck created significant risks to coil prolapse and parent vessel compromise, risking stroke. With other options of higher risks, we recommended an around-the-world technique. Standard transfemoral access was used to the right internal carotid artery (ICA) with a 6F-Shuttle sheath and intracranial carotid with a 6F-Sofia distal access catheter. With dual-microcatheter access, 1 catheter was placed in the aneurysm dome, a second in the MCA for stent placement. Advancing the wire around the aneurysm first formed a loop from the lateral to medial wall for access to the MCA. The microcatheter was then advanced around the wire into the MCA, keeping the loop within the dome. With the loop's distal tip anchored, the distal end of the stent was deployed and anchored into the MCA. Both pitfalls (ie, lack of sufficient distal access, collapse of stent device during deployment) were resolved using a balloon catheter. With the balloon positioned and inflated as the anchor, the wire and catheter were pulled together. The loop in the aneurysm's dome straightened out across the neck, the stent was advanced into the MCA, and coiling proceeded. A large neck remnant had partially closed on 6-mo follow-up angiogram. Patient consented to undergo the procedure. Illustrations in video published/printed with permission from Mayfield Clinic.
Stent-Assisted Coiling of a Sidewall Aneurysm of the Distal Middle Cerebral Artery: 2-Dimensional Operative Video

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E37-E38

10.1093/ons/opaa332 | PMID 33316814

Abstract Sidewall aneurysm treatment often requires complex management strategies. These can include advanced clipping techniques or stent-assisted coiling techniques. Endovascular coiling alone has been associated with high recurrence rates and is often not feasible. 1-4 Flow-diversion embolization has recently become a standard of care for many aneurysms, demonstrating high occlusion rates. 4,5 However, the third generation of coil-assist stents can be delivered with 0.0165” microcatheters, being an ideal adjunct to manage this group of aneurysms in more distal locations. In this video, a 16-yr-old teenager with Parry-Romberg syndrome and congenital adrenal hyperplasia had an incidental finding of a 6.5-mm sidewall aneurysm arising off the angular branch of the left middle cerebral artery, found during the work-up of complex partial seizures. The patient consented to the procedure. Due to his young age and aneurysm size, a decision was made to treat the aneurysm through an endovascular approach. Under general anesthesia, a transfemoral approach was carried out using a 6-French short sheath. A 6-French guiding catheter was left in the distal cervical left internal carotid artery; a 0.0165” microcatheter was used to first deploy a 3.0 × 15 mm Neuroform Atlas stent, completely covering the length of the aneurysm. Then, the stent was traversed with the microcatheter to coil the aneurysm. Follow-up cerebral angiogram confirmed complete occlusion of the aneurysm.
Delayed presentation of acute ischemic strokes during the COVID-19 crisis

Journal of NeuroInterventional Surgery | May 28, 2020 | Volume: 12 | Issue: 7 | Pages: 639-642

10.1136/neurintsurg-2020-016299 | PMID 32467244

Background The COVID-19 pandemic has disrupted established care paths worldwide. Patient awareness of the pandemic and executive limitations imposed on public life have changed the perception of when to seek care for acute conditions in some cases. We sought to study whether there is a delay in presentation for acute ischemic stroke patients in the first month of the pandemic in the US. Methods The interval between last-known-well (LKW) time and presentation of 710 consecutive patients presenting with acute ischemic strokes to 12 stroke centers across the US were extracted from a prospectively maintained quality database. We analyzed the timing and severity of the presentation in the baseline period from February to March 2019 and compared results with the timeframe of February and March 2020. Results There were 320 patients in the 2-month baseline period in 2019, there was a marked decrease in patients from February to March of 2020 (227 patients in February, and 163 patients in March). There was no difference in the severity of the presentation between groups and no difference in age between the baseline and the COVID period. The mean interval from LKW to the presentation was significantly longer in the COVID period (603±1035 min) compared with the baseline period (442±435 min, P<0.02). Conclusion We present data supporting an association between public awareness and limitations imposed on public life during the COVID-19 pandemic in the US and a delay in presentation for acute ischemic stroke patients to a stroke center.
The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil

Neurosurgery | February 10, 2020 | Volume: 86 | Issue: 5 | Pages: 615-624

10.1093/neuros/nyaa006 | PMID 32078692

Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract
Evaluation of previously embolized intracranial aneurysms: inter-and intra-rater reliability among neurosurgeons and interventional neuroradiologists

Journal of NeuroInterventional Surgery | September 16, 2017 | Volume: 10 | Issue: 5 | Pages: 462-466

10.1136/neurintsurg-2017-013231 | PMID 28918386

Background The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. Objective The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. Methods A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0–100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. Results 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). Conclusions Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population.