Citations 22

A Radiomics-Based Classifier for the Progression of Oropharyngeal Cancer Treated with Definitive Radiotherapy

Cancers | July 24, 2023 | Volume: 15 | Issue: 14 | Pages: 3715

10.3390/cancers15143715 | PMID 37509376

In this study, we investigated whether radiomics features from pre-treatment positron emission tomography (PET) images could be used to predict disease progression in patients with HPV-positive oropharyngeal cancer treated with definitive proton or x-ray radiotherapy. Machine learning models were built using a dataset from Mayo Clinic, Rochester, Minnesota (n = 72) and tested on a dataset from Mayo Clinic, Phoenix, Arizona (n = 22). A total of 71 clinical and radiomics features were considered. The Mann–Whitney U test was used to identify the top 2 clinical and top 20 radiomics features that were significantly different between progression and progression-free patients. Two dimensionality reduction methods were used to define two feature sets (manually filtered or machine-driven). A forward feature selection scheme was conducted on each feature set to build models of increased complexity (number of input features from 1 to 6) and evaluate model robustness and overfitting. The machine-driven features had superior performance and were less prone to overfitting compared to the manually filtered features. The four-variable Gaussian Naïve Bayes model using the ‘Radiation Type’ clinical feature and three machine-driven features achieved a training accuracy of 79% and testing accuracy of 77%. These results demonstrate that radiomics features can provide risk stratification beyond HPV-status to formulate individualized treatment and follow-up strategies.
Incremental retraining, clinical implementation, and acceptance rate of deep learning auto‐segmentation for male pelvis in a multiuser environment

Medical Physics | June 8, 2023 | Volume: 50 | Issue: 7 | Pages: 4079-4091

10.1002/mp.16537 | PMID 37287322

AbstractBackgroundDeep learning auto‐segmentation (DLAS) models have been adopted in the clinic; however, they suffer from performance deterioration owing to the clinical practice variability. Some commercial DLAS software provide an incremental retraining function that enables users to train a custom model using their institutional data to account for clinical practice variability.PurposeThis study was performed to evaluate and implement the commercial DLAS software with the incremental retraining function for definitive treatment of patients with prostate cancer in a multi‐user environment.MethodsCT‐based target organs and organs‐at‐risk (OAR) delineation of 215 prostate cancer patients were utilized. The performance of three commercial DLAS software built‐in models was validated with 20 patients. A retrained custom model was developed using 100 patients and evaluated on the remaining data (n = 115). Dice similarity coefficient (DSC), Hausdorff distance (HD), mean surface distance (MSD), and surface DSC (SDSC) were utilized for quantitative evaluation. A multi‐rater qualitative evaluation was blindly performed with a five‐level scale. Visual inspection was performed in consensus and non‐consensus unacceptable cases to identify the failure modes.ResultsThree commercial DLAS vendor built‐in models achieved sub‐optimal performance in 20 patients. The retrained custom model had a mean DSC of 0.82 for prostate, 0.48 for seminal vesicles (SV), and 0.92 for rectum, respectively. This represents a significant improvement over the built‐in model with DSC of 0.73, 0.37, and 0.81 for the corresponding structures. Compared to the acceptance rate of 96.5% and consensus unacceptable rate (i.e., both reviewers rated as unacceptable) of 3.5% achieved by manual contours, the custom model achieved a 91.3% acceptance rate and 8.7% consensus unacceptable rate. The failure modes of retrained custom model were attributed to the following: cystogram (n = 2), hip prosthesis (n = 2), low dose rate brachytherapy seeds (n = 2), air in endorectal balloon(n = 1), non‐iodinated spacer (n = 2), and giant bladder(n = 1).ConclusionThe commercial DLAS software with the incremental retraining function was validated and clinically adopted for prostate patients in a multi‐user environment. AI‐based auto‐delineation of the prostate and OARs is shown to achieve improved physician acceptance, overall clinical utility, and accuracy.
Clinical Practice Evolvement for Post-Operative Prostate Cancer Radiotherapy—Part 2: Feasibility of Margin Reduction for Fractionated Radiation Treatment with Advanced Image Guidance

Cancers | December 22, 2022 | Volume: 15 | Issue: 1 | Pages: 40

10.3390/cancers15010040 | PMID 36612040

Purpose: Planning target volume (PTV) expansion for post-prostatectomy radiotherapy is typically ≥5 mm. Recent clinical trials have proved the feasibility of a reduced margin of 2–3 mm for treatments on MRI-linac. We aim to study the minimum PTV margin needed using iterative cone-beam CT (iCBCT) as image guidance on conventional linacs. Materials/Methods: Fourteen patients who received post-prostatectomy irradiation (8 with an endorectal balloon and 6 without a balloon) were included in this study. Treatment was delivered with volumetric modulated radiation therapy (VMAT). Fractional dose delivery was evaluated in 165 treatment fractions. The bladder, rectal wall, femoral heads, and prostate bed clinical tumor volume (CTV) were contoured and verified on daily iCBCT. PTV margins (0 mm, 2 mm, and 4 mm) were evaluated on daily iCBCT. CTV coverage and OAR dose parameters were assessed with each PTV margin. Results: CTV D100% was underdosed with a 0 mm margin in 32% of fractions in comparison with 2 mm (6%) and 4 mm (6%) PTV margin (p ≤ 0.001). CTV D95% > 95% was met in 93–94% fractions for all PTV expansions. CTV D95% > 95% was achieved in more patients with an endorectal balloon than those without: 0 mm—90/91 (99%) vs. 63/74 (85%); 2 mm—90/91 (99%) vs. 65/75 (87%); 4 mm—90/90 (100%) vs. 63/73 (86%). There was no difference in absolute median change in CTV D95% (0.32%) for 0-, 2-, and 4 mm margins. The maximum dose remained under 108% for 100% (0 mm), 97% (2 mm), and 98% (4 mm) of images. Rectal wall maximum dose remained under 108% for 100% (0 mm), 100% (2 mm), and 98% (4 mm) of images. Conclusions: With high-quality iCBCT image guidance, PTV margin accounting for inter-fractional uncertainties can be safely reduced for post-prostatectomy radiotherapy. For fractionated radiotherapy, an isotropic expansion of 2 mm and 4 mm may be considered for margin expansion with and without the endorectal balloon. Future application for margin reduction needs to be further evaluated and considered with the advent of shorter post-prostatectomy radiation courses.
Clinical Practice Evolvement for Post-Operative Prostate Cancer Radiotherapy—Part 1: Consistent Organs at Risk Management with Advanced Image Guidance

Cancers | December 21, 2022 | Volume: 15 | Issue: 1 | Pages: 16

10.3390/cancers15010016 | PMID 36612013

Purpose: Post-operative prostate cancer patients are treated with full bladder instruction and the use of an endorectal balloon (ERB). We reassessed the efficacy of this practice based on daily image guidance and dose delivery using high-quality iterative reconstructed cone-beam CT (iCBCT). Methods: Fractional dose delivery was calculated on daily iCBCT for 314 fractions from 14 post-operative prostate patients (8 with and 6 without ERB) treated with volumetric modulated radiotherapy (VMAT). All patients were positioned using novel iCBCT during image guidance. The bladder, rectal wall, femoral heads, and prostate bed clinical tumor volume (CTV) were contoured and verified on daily iCBCT. The dose-volume parameters of the contoured organs at risk (OAR) and CTV coverage were assessed for the clinical impact of daily bladder volume variations and the use of ERB. Minimum bladder volume was studied, and a straightforward bladder instruction was explored for easy clinical adoption. Results: A “minimum bladder” contour, the overlap between the original bladder contour and a 15 mm anterior and superior expansion from prostate bed PTV, was confirmed to be effective in identifying cases that might fail a bladder constraint of V65% <60%. The average difference between the maximum and minimum bladder volumes for each patient was 277.1 mL. The daily bladder volumes varied from 62.4 to 590.7 mL and ranged from 29 to 286% of the corresponding planning bladder volume. The bladder constraint of V65% <60% was met in almost all fractions (98%). CTVs (D90%, D95%, and D98%) remained well-covered regardless of the absolute bladder volume daily variation or the presence of the endorectal balloon. Patients with an endorectal balloon showed smaller variation but a higher average maximum rectal wall dose (D0.03mL: 104.3% of the prescription) compared to patients without (103.3%). Conclusions: A “minimum bladder” contour was determined that can be easily generated and followed to ensure sufficient bladder sparing. Further analysis and validation are needed to confirm the utility of the minimal bladder contour. Accurate dose delivery can be achieved for prostate bed target coverage and OAR sparing with or without the use of ERB.
Technical note: Investigation of dose and LETd effect to rectum and bladder by using non‐straight laterals in prostate cancer receiving proton therapy

Medical Physics | October 8, 2022 | Volume: 49 | Issue: 12 | Pages: 7428-7437

10.1002/mp.16008 | PMID 36208196

AbstractBackgroundParallel‐opposed lateral beams are the conventional beam arrangements in proton therapy for prostate cancer. However, when considering linear energy transfer (LET) and RBE effects, alternative beam arrangements should be investigated.PurposeTo investigate the dose and dose averaged LET (LETd) impact of using new beam arrangements rotating beams 5°–15° posteriorly to the laterals in prostate cancer treated with pencil‐beam‐scanning (PBS) proton therapy.MethodsTwenty patients with localized prostate cancer were included in this study. Four proton treatment plans for each patient were generated utilizing 0°, 5°, 10°, and 15° posterior oblique beam pairs relative to parallel‐opposed lateral beams. Dose‐volume histograms (DVHs) from posterior oblique beams were analyzed. Dose‐LETd‐volume histogram (DLVH) was employed to study the difference in dose and LETd with each beam arrangement. DLVH indices, , defined as the cumulative absolute volume that has a dose of at least d (Gy[RBE]) and a LETd of at least l (keV/µm), were calculated for both the rectum and bladder to the whole group of patients and two‐sub groups with and without hydrogel spacer. These metrics were tested using Wilcoxon signed‐rank test.ResultsRotating beam angles from laterals to slightly posterior by 5°–15° reduced high LETd volumes while it increased the dose volume in the rectum and increased LETd in bladders. Beam angles rotated five degrees posteriorly from laterals (i.e., gantry in 95° and 265°) are proposed since they achieved the optimal balance of better LETd sparing and minimal dose increase in the rectum. A reduction of V(50 Gy[RBE], 2.6 keV/µm) from 7.41 to 3.96 cc (p < 0.01), and a slight increase of V(50 Gy[RBE], 0 keV/µm) from 20.1 to 21.6 cc (p < 0.01) were observed for the group without hydrogel spacer. The LETd sparing was less effective for the group with hydrogel spacer, which achieved the reduction of V(50 Gy[RBE], 2.6 keV/µm) from 4.28 to 2.10 cc (p < 0.01).ConclusionsPosterior oblique angle plans improved LETd sparing of the rectum while sacrificing LETd sparing in the bladder in the treatment of prostate cancer with PBS. Beam angle modification from laterals to slightly posterior may be a strategy to redistribute LETd and perhaps reduce rectal toxicity risks in prostate cancer patients treated with PBS. However, the effect is reduced for patients with hydrogel spacer.
Exploratory study of seed spots analysis to characterize dose and linear‐energy‐transfer effect in adverse event initialization of pencil‐beam‐scanning proton therapy

Medical Physics | July 12, 2022 | Volume: 49 | Issue: 9 | Pages: 6237-6252

10.1002/mp.15859 | PMID 35820062

AbstractBackgroundBoth dose and linear energy transfer (LET) could play a substantial role in adverse event (AE) initialization of cancer patients treated with pencil‐beam‐scanning (PBS) proton therapy. However, not all the voxels within the AE regions are directly induced from the dose and LET effect. It is important to study the synergistic effect of dose and LET in AE initialization by only including a subset of voxels that are dosimetrically important.PurposeTo perform exploratory investigation of the dose and LET effects upon AE initialization in PBS using seed spots analysis.MethodsA total of 113 head‐and‐neck (H&N) cancer patients receiving curative PBS were included. Among them, 20 patients experienced unanticipated CTCAEv4.0 grade ≥3 AEs (AE group) and 93 patients did not (control group). Within the AE group, 13 AE patients were included in the seed spot analysis to derive the descriptive features of AE initialization and the remaining 7 mandible osteoradionecrosis patients and 93 control patients were used to derive the feature‐based volume constraint of mandible osteoradionecrosis. The AE regions were contoured and the corresponding dose–LET volume histograms of AE regions were generated for all patients in the AE group. We selected high LET voxels (the highest 5% of each dose bin) with a range of moderate‐to‐high dose (≥∼40‐Gy relative biological effectiveness) as critical voxels. Critical voxels that were contiguous with each other were grouped into clusters. Each cluster was considered a potential independent seed spot for AE initialization. Seed spots were displayed in a 2D dose–LET plane based on their mean dose and LET to derive the descriptive features of AE initialization. A volume constraint of mandible osteoradionecrosis was then established based on the extracted features using a receiver operating characteristic curve.ResultsThe product of dose and LET (xBD) was found to be a descriptive feature of seed spots leading to AE initialization in this preliminary study. The derived xBD volume constraint for mandible osteoradionecrosis showed good performance with an area under curve of 0.87 (sensitivity of 0.714 and specificity of 0.807 in the leave‐one‐out cross‐validation) for the very limited patient data included in this study.ConclusionOur exploratory study showed that both dose and LET were observed to be important in AE initializations. The derived xBD volume constraint could predict mandible osteoradionecrosis reasonably well in the very limited H&N cancer patient data treated with PBS included in this study.
A Phase II prospective study of hypofractionated proton therapy of prostate and pelvic lymph nodes: Acute effects on patient‐reported quality of life

The Prostate | July 5, 2022 | Volume: 82 | Issue: 14 | Pages: 1338-1345

10.1002/pros.24408 | PMID 35789497

AbstractBackgroundThe objective of this study was to report acute changes in patient‐reported quality of life (PRQOL) using the 26‐item Expanded Prostate Index Composite (EPIC‐26) questionnaire in a prospective study using hypofractionated intensity‐modulated proton beam therapy (H‐IMPT) targeting the prostate and the pelvic lymph nodes for high‐risk or unfavorable intermediate‐risk prostate cancer.MethodsFifty‐five patients were enrolled. H‐IMPT consisted of 45 GyE to the pelvic lymph nodes and 67.5 GyE to the prostate and seminal vesicles in 25 fractions. PRQOL was assessed with the urinary incontinence (UI), urinary irritative/obstructive symptoms (UO), and bowel function (BF) domains of EPIC‐26 questionnaire. Mean changes in domain scores were analyzed from pretreatment to the end of treatment and 3 months posttreatment. A clinically meaningful change (or minimum important change) was defined as a score change > 50% of the baseline standard deviation.ResultsThe mean scores of UO, UI, and BF at baseline were 84.6, 91.1, and 95.3, respectively. At the end of treatment, there were statistically significant and clinically meaningful declines in UO and BF scores (−13.5 and −2.3, respectively), while the decline in UI score was statistically significant but not clinically meaningful (−13.7). A clinically meaningful decline in UO, UI, and BF scores occurred in 53.5%, 22.7%, and 73.2% of the patients, respectively. At 3 months posttreatment, all three mean scores showed an improvement, with fewer patients having a clinically meaningful decline in UO, UI, and BF scores (18.4%, 20.5%, and 45.0%, respectively). There was no significant reduction in the mean UO and UI scores compared to baseline, although the mean BF score remained lower than baseline and the difference was clinically meaningful.ConclusionsUO, UI, and BF scores of PRQOL declined at the end of H‐IMPT. UO and UI scores showed improvement at 3 months posttreatment and were similar to the baseline scores. However, BF score remained lower at 3 months posttreatment with a clinically meaningful decline.
Toxicity and outcomes after external beam irradiation for prostate cancer in patients with prior holmium laser enucleation of the prostate: Early experience

Cancer Reports | July 5, 2022 | Volume: 6 | Issue: 1 | Pages: No page available

10.1002/cnr2.1672 | PMID 35790091

AbstractPurpose/ObjectivesHolmium laser enucleation of the prostate (HoLEP) is commonly performed in patients with significant bladder outlet obstruction. However, there are few reports on the toxicity of external beam irradiation (RT) for prostate cancer in patients after prior HoLEP. In this study, we evaluate the side effects and treatment outcomes of RT after HoLEP.Materials/MethodsEighteen patients who had HoLEP and subsequently received RT for prostate cancer were included. Data collected included patient and disease characteristics, urinary function, and radiation dose. Acute and late urinary (GU) and gastrointestinal (GI) side effects were evaluated. Disease control and survival rates were calculated using Kaplan–Meier method.ResultsMedian follow‐up was 18 months (range: 4–46 months). Median prostate volume was 107 ml before HoLEP and 24 ml after HoLEP. Median International Prostate Symptom Score (IPSS) was 17 (range: 5–32) before HoLEP. Median decline in IPSS score after HoLEP was 7 (range: −2–21). On uroflow study, peak flow rate, and post‐void residual were significantly improved after HoLEP. After radiation, peak flow rate and average flow rate showed a decline but remained significantly improved compared to pre‐HoLEP measurements. Maximum acute Common Terminology Criteria for Adverse Events (CTCAE) adverse events were 12 grade 1 and 3 grade 2 for GU, and 3 grade 1 for GI, respectively. Maximum late adverse events were 13 grade 1 and 2 grade 2 for GU, and all grade 0 for GI, respectively. At last follow‐up, there were 8 grade 1 and 1 grade 2 late GU, and 3 grade 1 late GI adverse events, respectively. There was no significant increase in urinary incontinence after RT compared to before RT. The 18‐month biochemical control, local control, distant control rates were 78%, 94%, and 80%, respectively.ConclusionsPatients who received RT as definitive treatment for prostate cancer after prior HoLEP had low risk of serious acute and late side effects. HoLEP can be safely performed and should be considered in patients with significant bladder outlet obstruction and large prostate volume before RT.
A phase II trial of hypofractionated radiation therapy over five treatments for prostate cancer with high-risk features after radical prostatectomy: MC1754.

Journal of Clinical Oncology | February 16, 2022 | Volume: 40 | Issue: 6_suppl | Pages: 248-248

10.1200/jco.2022.40.6_suppl.248

248 Background: Hypofractionated prostate cancer radiation has showed similar results in several prior phase III studies (PCG GU 003, PACE-B, and Hypo PC RT). However, prospective phase II-III clinical trial data testing 5 tx after prostatectomy is scarce. Methods: Between 2018 and 2019, 41 patients were treated after postprostatectomy for high risk features. 5 patients were treated adjuvantly, 36 for salvage including 8 with oligometastatic disease. Indications for adjuvant RT included a PSA < 0.2 and +margins, SVI, or EPE. Salvage RT was offered for PSA ≥0.2. Oligometastatic RT for patients with ≤5 RT targets. Staging included C11 PET for all cases. Total dose to the prostate bed was 30-32 Gy in 5tx QOD with IMRT, conebeam IGRT, and MRI registration. All salvage patients received ADT for 6 months and oligometastatic patients for 18 months. Dose to the metastatic sites was 30 in 5tx QOD. Of the 41 patients 8 also received SBRT to the sites of oligometastatic disease. We looked at clinical outcomes defining biochemical failure as a PSA > 0.2 after treatment, baseline adjusted CTC AE V5.0, baseline adjusted patient reported toxicities (PRO CTC AE), QOL (EPIC, PROMIS), and AUA was used for all cases. Results: Median follow up was 23 months (range 10-37). Pre-RT T stage was T2-T3b, with 47% being T3a-b; Pre RT Median PSA of 0.4 (range < 0.1-1.9); Median GS 8 (6-9); and (+) margins in 48.8%. Sites of oligometastatic disease radiated included the LN and bone. Treatment related AE were grade 0-1 in all cases, except for one patient with G2 GU incontinence. Overall QOL remained high during follow including Promis 10 overall, mental, and physical scores; urinary bother, irritative/obstructive, and AUA scores; bowel overall, bowel bother, and bowel function scores; and overall sexual, sexual function, and sexual bother scores remained at baseline levels during follow up. Only hormonal overall, hormonal function, and hormonal bother had lower scores at 3 months that recovered by 12 months in patients treated with ADT for 6 months and by 24 months in patients treated with ADT for 18 months. A total of 3 clinical failure have been seen; 2 patients with regional failures alone; and one with axial skeleton bony failures for 93% clinical control at median follow up of 23 months. All 3 patients with clinical failure were salvaged successfully with SBRT and all patients remain disease free at last follow up. A total 5 patients with raising PSAs alone have been seen. All patients have been re-staged with C11 PET. No failures in the prostate bed or previously radiated sites have been seen. Conclusions: Toxicity for RT over 5tx is lower than expected with only one case of grade 2 urinary incontinence. QOL scores remained high during follow up, minor changes in hormonal scores were seen during ADT, but recovered after. 30-32 Gy over 5 tx provided 100% control in radiated targets and metastatic sites. Clinical trial information: NCT03570827.
An comparison of acute toxicities and patient‐reported outcomes between intensity‐modulated proton therapy and volumetric‐modulated arc therapy after ipsilateral radiation for head and neck cancers

Head & Neck | December 3, 2021 | Volume: 44 | Issue: 2 | Pages: 359-371

10.1002/hed.26937 | PMID 34859516

Abstract BACKGROUND Intensity‐modulated proton therapy (IMPT) demonstrates superior dose distribution over volumetric‐modulated arc therapy (VMAT) for sparing organs‐at‐risk (OARs) in ipsilateral radiotherapy. To determine a clinical benefit, assessment of patient‐reported outcomes (PRO) and physician‐reported toxicities alongside a dosimetric analysis is needed. METHODS Plans were analyzed for dosimetric differences. PROs were compared for patients undergoing ipsilateral curative‐intent radiotherapy for tonsil and salivary gland cancers with VMAT or IMPT from 2015 to 2020. Physician‐reported toxicities were compared. RESULTS In 40 patients, IMPT was associated with decreased dose to multiple OARs and less deterioration in the following PROs: pain, swallowing function, dry mouth, sticky saliva, sensory change, cough, speech, feeling ill, and social eating. Physician‐reported toxicities demonstrated less oral pain. CONCLUSION IMPT is associated with decreased dose to OARs and less patient‐reported acute deterioration in multiple head and neck domains. A strong consideration for IMPT in ipsilateral head and neck patients with cancer is warranted.