Citations 23

Contractile Smooth Muscle and Active Stress Generation in Porcine Common Carotids

Journal of Biomechanical Engineering | October 3, 2017 | Volume: 140 | Issue: 1 | Pages: No page available

10.1115/1.4037949 | PMID 28975258

The mechanical response of intact blood vessels to applied loads can be delineated into passive and active components using an isometric decomposition approach. Whereas the passive response is due predominantly to the extracellular matrix (ECM) proteins and amorphous ground substance, the active response depends on the presence of smooth muscle cells (SMCs) and the contractile machinery activated within those cells. To better understand determinants of active stress generation within the vascular wall, we subjected porcine common carotid arteries (CCAs) to biaxial inflation–extension testing under maximally contracted or passive SMC conditions and semiquantitatively measured two known markers of the contractile SMC phenotype: smoothelin and smooth muscle-myosin heavy chain (SM-MHC). Using isometric decomposition and established constitutive models, an intuitive but novel correlation between the magnitude of active stress generation and the relative abundance of smoothelin and SM-MHC emerged. Our results reiterate the importance of stretch-dependent active stress generation to the total mechanical response. Overall these findings can be used to decouple the mechanical contribution of SMCs from the ECM and is therefore a powerful tool in the analysis of disease states and potential therapies where both constituent are altered.
Ultrasound elastography for carpal tunnel pressure measurement: A cadaveric validation study

Journal of Orthopaedic Research | July 21, 2017 | Volume: 36 | Issue: 1 | Pages: 477-483

10.1002/jor.23658 | PMID 28731271

ABSTRACT Carpal tunnel pressure is a key factor in the etiology of carpal tunnel syndrome. Numerous approaches have been conducted to measure carpal tunnel pressure. However, most techniques are invasive and take time and effort. We have developed an innovative approach to noninvasively assess the tunnel pressure by using the ultrasound surface wave elastography (USWE) technique. In a previous study it was shown that the shear wave speed in a tendon increased linearly with increasing tunnel pressure enclosed the tendon in a simple tendon model. This study aimed to examine the relationship between the carpal tunnel pressure and the shear wave speeds inside and outside the carpal tunnel in a human cadaveric model. The result showed that the shear wave speed inside the carpal tunnel increased linearly with created carpal tunnel pressure, while the shear wave speed outside the carpal tunnel remained constant. These findings suggest that noninvasive measurement of carpal tunnel pressure is possible by measuring the shear wave speed in the tendon. After fully establishing this technology and being applicable in clinic, it would be useful in the diagnosis of carpal tunnel syndrome. For that reason, further validation with this technique in both healthy controls and patients with carpal tunnel syndrome is required. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:477–483, 2018.
An ultrasound surface wave elastography technique for noninvasive measurement of surface lung tissue

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3721-3721

10.1121/1.4988149

Ultrasonography is not widely used in clinic for lung assessment because ultrasound cannot image deep lung tissue. In this abstract, we present a novel technique, lung ultrasound surface wave elastography (LUSWE), for measuring the elastic properties of superficial lung tissue. In LUSWE, a small, local, and 0.1 second harmonic vibration is generated on the chest of a subject. The speed of surface wave on the lung is measured by using an ultrasound probe. We are evaluating LUSWE for assessing patients with interstitial lung disease (ILD). LUSWE may be useful for assessing ILD because most ILD patients have typical fibrotic scars in the peripheral and subpleural regions of the lung. In a large clinical study of ILD patients, we measure both lungs through six intercostal spaces for patients and controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. In an example, the surface wave speed is 1.88 ± 0.11 m/s and 3.3 ± 0.37 m/s, respectively, for a healthy subject and an ILD patient at 100 Hz and in the same intercostal space. LUSWE may compliment the clinical standard high-resolution computed tomography for assessing ILD. LUSWE may be useful for assessing other lung disorders.