The purpose of this paper is to describe the intraoperative management of a type IIIb endoleak after deployment of a bifurcated endograft in a patient with narrow iliac access vessels. A 62-year-old man underwent elective endovascular repair (EVAR) of a 53 mm abdominal aortic aneurysm. After device deployment, a large IIIb endoleak, arising from the main body of the device, was visualized. Narrow iliac vessels precluded deployment of a second bifurcated graft, and the endoleak was successfully excluded with an aortomonoiliac device, followed by contralateral iliac occlusion and subsequent creation of a femorofemoral bypass. At 1-year follow-up, the aneurysm remains excluded and is decreasing in size. Type III endoleaks are a known complication of EVAR, requiring immediate treatment through their association with aneurysm enlargement and rupture. If an additional bifurcated graft cannot be used, aortomonoiliac conversion represents a feasible endovascular alternative treatment for type III endoleaks, other than conversion to open surgical repair. Therefore, aortomonoiliac converters with appropriate occluder devices should be readily available during deployment of bifurcated devices.
A Comparison of AneuRx Aortic Cuff and Zenith Distal Flare Exclusion of Common Iliac Artery Ectasia for Endovascular Aneurysm Repair
Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 1 | Pages: 51-56
Stent-grafts are ideally terminated within the common iliac artery (CIA). However, CIA ectasia may require hypogastric artery occlusion, with stent-graft extension to the external iliac artery. Alternatively, the diameter of the distal stent-graft may be increased, or flared, to allow exclusion of the abdominal aortic aneurysm. This report details the authors’ experience with this technique. Forty-one patients received bifurcated stent-grafts (BSG): 20 received an AneuRx device, and 21 received a Zenith device. CIA ectasia (diameter 15–25 mm) was treated with a distal flare of 2–4 mm greater than the CIA diameter. Patients were followed up with computed tomography scan at 1, 6, and 12 months. Statistical analysis was performed using ANOVA within groups and unpaired two-tailed t test between groups. A p value of <0.05 was considered significant. Eight of 20 patients (40%) (11 CIA) received an AneuRx device and 13/21 (62%) (17 CIA) received a Zenith device, with a distal flare. Values are (n) mean (mm) ± SE. There were no deaths, endoleaks, migrations, or conversions to open repair. Follow-up mean was 24.7 and 20.6 (range 15–28) months for AneuRx and Zenith groups, respectively. In comparing initial and 12-month CIA diameters, AneuRx grafts 20 ±0.8 vs 21.5 ±1.0 were not significantly different, p= 0.2, nor was the same comparison for Zenith, 17 ±0.5 vs 19.1 ±0.4, significant, p= 0.57. At a mean follow-up of 12 months, distal flare of iliac limbs with either AneuRx or Zenith devices affords a seal for CIA ectasia and/or aneurysms complicating EVAR.
Delayed Transcaval Renal Penetration Of A Greenfield Filter Presenting As Symptomatic Hydronephrosis
Journal of Urology | January 17, 2006 | Volume: 167 | Issue: 4 | Pages: 1778-1779