Back to Authors

Fiehler, Jens

https://orcid.org/0000-0001-8533-7478

A5061175108 | I4210108711

Mayo Clinic

University Medical Center Hamburg-Eppendorf

Citations 22

Pretreatment predictors of very poor clinical outcomes in medium vessel occlusion stroke patients treated with mechanical thrombectomy

International Journal of Stroke | July 30, 2024 | Volume: 19 | Issue: 10 | Pages: 1123-1133

10.1177/17474930241270524 | PMID 39075759

Background: Acute ischemic stroke (AIS) from primary medium vessel occlusions (MeVO) is a prevalent condition associated with substantial morbidity and mortality. Despite the common use of mechanical thrombectomy (MT) in AIS, predictors of poor outcomes in MeVO remain poorly characterized. Methods: In this prospectively collected, retrospectively reviewed, multicenter, multinational study, data from the MAD-MT (Multicenter Analysis of primary Distal medium vessel occlusions: effect of Mechanical Thrombectomy) registry were analyzed. The study included 1568 patients from 37 academic centers across North America, Asia, and Europe, treated with MT, with or without intravenous tissue plasminogen activator (IVtPA), between September 2017 and July 2021. Results: Among the 1568 patients, 347 (22.2%) experienced very poor outcomes (modified Rankin score (mRS), 5–6). Key predictors of poor outcomes were advanced age (odds ratio (OR): 1.03; 95% confidence interval (CI): 1.02 to 1.04; p < 0.001), higher baseline National Institutes of Health Stroke Scale (NIHSS) scores (OR: 1.07; 95% CI: 1.05 to 1.10; p < 0.001), pre-operative glucose levels (OR: 1.01; 95% CI: 1.00 to 1.02; p < 0.001), and a baseline mRS of 4 (OR: 2.69; 95% CI: 1.25 to 5.82; p = 0.011). The multivariable model demonstrated good predictive accuracy with an area under the receiver-operating characteristic (ROC) curve of 0.76. Conclusions: This study demonstrates that advanced age, higher NIHSS scores, elevated pre-stroke mRS, and pre-operative glucose levels significantly predict very poor outcomes in AIS-MeVO patients who received MT. These findings highlight the importance of a comprehensive risk assessment in primary MeVO patients for personalized treatment strategies. However, they also suggest a need for cautious patient selection for endovascular thrombectomy. Further prospective studies are needed to confirm these findings and explore targeted therapeutic interventions.
Symptomatic intracerebral hemorrhage in proximal and distal medium middle cerebral artery occlusion patients treated with mechanical thrombectomy

Journal of NeuroInterventional Surgery | July 8, 2024 | Volume: 17 | Issue: 8 | Pages: 803-810

10.1136/jnis-2024-021879 | PMID 38977305

Background Acute ischemic stroke (AIS) caused by distal medium vessel occlusions (DMVOs) represents a significant proportion of overall stroke cases. While intravenous thrombolysis (IVT) has been a primary treatment, advancements in endovascular procedures have led to increased use of mechanical thrombectomy (MT) in DMVO stroke patients. However, symptomatic intracerebral hemorrhage (sICH) remains a critical complication of AIS, particularly after undergoing intervention. This study aims to identify factors associated with sICH in DMVO stroke patients undergoing MT. Methods This retrospective analysis utilized data from the Multicenter Analysis of Distal Medium Vessel Occlusions: Effect of Mechanical Thrombectomy (MAD-MT) registry, involving 37 centers across North America, Asia, and Europe. Middle cerebral artery (MCA) DMVO stroke patients were included. The primary outcome measured was sICH, as defined per the Heidelberg Bleeding Classification. Univariable and multivariable logistic regression were used to identify factors independently associated with sICH. Results Among 1708 DMVO stroke patients, 148 (8.7%) developed sICH. Factors associated with sICH in DMVO patients treated with MT included older age (adjusted odds ratio (aOR) 1.01, 95% confidence interval (95% CI) 1.00 to 1.03, P=0.048), distal occlusion site (M3, M4) compared with medium occlusions (M2) (aOR 1.71, 95% CI 1.07 to 2.74, P=0.026), prior use of antiplatelet drugs (aOR 2.06, 95% CI 1.41 to 2.99, P<0.001), lower Alberta Stroke Program Early CT Scores (ASPECTS) (aOR 0.75, 95% CI 0.66 to 0.84, P<0.001), higher preoperative blood glucose level (aOR 1.00, 95% CI 1.00 to 1.01, P=0.012), number of passes (aOR 1.27, 95% CI 1.15 to 1.39, P<0.001), and successful recanalization (Thrombolysis In Cerebral Infarction (TICI) 2b-3) (aOR 0.43, 95% CI 0.28 to 0.66, P<0.001). Conclusion This study provides novel insight into factors associated with sICH in patients undergoing MT for DMVO, emphasizing the importance of age, distal occlusion site, prior use of antiplatelet drugs, lower ASPECTS, higher preoperative blood glucose level, and procedural factors such as the number of passes and successful recanalization. Pending confirmation, consideration of these factors may improve personalized treatment strategies.
Contour Neurovascular System for endovascular embolization of cerebral aneurysms: a multicenter cohort study of 10 European neurovascular centers

Journal of NeuroInterventional Surgery | May 17, 2024 | Volume: 17 | Issue: 4 | Pages: 399-404

10.1136/jnis-2023-021378 | PMID 38760167

Background Intrasaccular devices have become increasingly popular in the treatment of cerebral aneurysms, particularly at the bifurcation. Here we evaluate the Contour Neurovascular System, an intrasaccular device for the endovascular treatment of cerebral aneurysms, in a multicenter cohort study, the largest to the best of our knowledge. Methods Consecutive patients with intracranial aneurysms treated with the Contour Neurovascular System between February 2017 and October 2022 at 10 European neurovascular centers were prospectively collected and retrospectively reviewed. Patient and aneurysm characteristics, procedural details, and angiographic and clinical outcomes were evaluated. Results During the study period, 279 aneurysms (median age of patients 60 years, IQR 52–68) were treated with Contour. In 83.2% of patients the device was placed electively, whereas the remaining patients were treated in the setting of acute subarachnoid hemorrhage. The most common locations were the middle cerebral artery (26.5%) followed by the anterior communicating region (26.2%). Median aneurysm dome and neck size were 5.2 mm (IQR 4.2–7) and 3.9 mm (IQR 3–5). Contour size 7 (39%) and 9 (25%) were most used. Thromboembolic and hemorrhagic complications occurred in 6.8% and 0.4% of aneurysms, respectively. Raymond-Roy 1 and 2 occlusions at last follow-up were achieved in 63.2% and 28.3%, respectively, resulting in adequate occlusion of 91.5% of aneurysms. Conclusion This is the largest multicenter study reporting the outcome on the Contour Neurovascular System. At 1 year, the self-evaluated data on safety and efficacy are comparable to data of existing intrasaccular devices. Contour is a promising technology in the treatment of cerebral aneurysms.
Outcomes of mechanical thrombectomy in anticoagulated patients with acute distal and medium vessel stroke

European Stroke Journal | May 10, 2024 | Volume: 9 | Issue: 4 | Pages: 896-906

10.1177/23969873241249295 | PMID 38726983

Abstract Background: Stroke remains a major health concern globally, with oral anticoagulants widely prescribed for stroke prevention. The efficacy and safety of mechanical thrombectomy (MT) in anticoagulated patients with distal medium vessel occlusions (DMVO) are not well understood. Methods: This retrospective analysis involved 1282 acute ischemic stroke (AIS) patients who underwent MT in 37 centers across North America, Asia, and Europe from September 2017 to July 2023. Data on demographics, clinical presentation, treatment specifics, and outcomes were collected. The primary outcomes were functional outcomes at 90 days post-MT, measured by modified Rankin Scale (mRS) scores. Secondary outcomes included reperfusion rates, mortality, and hemorrhagic complications. Results: Of the patients, 223 (34%) were on anticoagulation therapy. Anticoagulated patients were older (median age 78 vs 74 years; p &lt; 0.001) and had a higher prevalence of atrial fibrillation (77% vs 26%; p &lt; 0.001). Their baseline National Institutes of Health Stroke Scale (NIHSS) scores were also higher (median 12 vs 9; p = 0.002). Before propensity score matching (PSM), anticoagulated patients had similar rates of favorable 90-day outcomes (mRS 0–1: 30% vs 37%, p = 0.1; mRS 0–2: 47% vs 50%, p = 0.41) but higher mortality (26% vs 17%, p = 0.008). After PSM, there were no significant differences in outcomes between the two groups. Conclusion: Anticoagulated patients undergoing MT for AIS due to DMVO did not show significant differences in 90-day mRS outcomes, reperfusion, or hemorrhage compared to non-anticoagulated patients after adjustment for covariates.
Incidence and clinical outcomes of perforations during mechanical thrombectomy for medium vessel occlusion in acute ischemic stroke: A retrospective, multicenter, and multinational study

European Stroke Journal | February 27, 2024 | Volume: 9 | Issue: 2 | Pages: 328-337

10.1177/23969873231219412 | PMID 38409796

Abstract Background: Mechanical thrombectomy (MT) has revolutionized the treatment of acute ischemic stroke (AIS) due to large vessel occlusion (LVO), but its efficacy and safety in medium vessel occlusion (MeVO) remain less explored. This multicenter, retrospective study aims to investigate the incidence and clinical outcomes of vessel perforations (confirmed by extravasation during an angiographic series) during MT for AIS caused by MeVO. Methods: Data were collected from 37 academic centers across North America, Asia, and Europe between September 2017 and July 2021. A total of 1373 AIS patients with MeVO underwent MT. Baseline characteristics, procedural details, and clinical outcomes were analyzed. Results: The incidence of vessel perforation was 4.8% (66/1373). Notably, our analysis indicates variations in perforation rates across different arterial segments: 8.9% in M3 segments, 4.3% in M2 segments, and 8.3% in A2 segments (p = 0.612). Patients with perforation had significantly worse outcomes, with lower rates of favorable angiographic outcomes (TICI 2c-3: 23% vs 58.9%, p &lt; 0.001; TICI 2b-3: 56.5% vs 88.3%, p &lt; 0.001). Functional outcomes were also worse in the perforation group (mRS 0–1 at 3 months: 22.7% vs 36.6%, p = 0.031; mRS 0–2 at 3 months: 28.8% vs 53.9%, p &lt; 0.001). Mortality was higher in the perforation group (30.3% vs 16.8%, p = 0.008). Conclusion: This study reveals that while the occurrence of vessel perforation in MT for AIS due to MeVO is relatively rare, it is associated with poor functional outcomes and higher mortality. The findings highlight the need for increased caution and specialized training in performing MT for MeVO. Further prospective research is required for risk mitigation strategies.
First pass effect as an independent predictor of functional outcomes in medium vessel occlusions: An analysis of an international multicenter study

European Stroke Journal | October 27, 2023 | Volume: 9 | Issue: 1 | Pages: 114-123

10.1177/23969873231208276 | PMID 37885243

Abstract Introduction: First pass effect (FPE), achievement of complete recanalization (mTICI 2c/3) with a single pass, is a significant predictor of favorable outcomes for endovascular treatment (EVT) in large vessel occlusion stroke (LVO). However, data concerning the impact on functional outcomes and predictors of FPE in medium vessel occlusions (MeVO) are scarce. Patients and Methods: We conducted an international retrospective study on MeVO cases. Multivariable logistic modeling was used to establish independent predictors of FPE. Clinical and safety outcomes were compared between the two study groups (FPE vs non-FPE) using logistic regression models. Good outcome was defined as modified Rankin Scale 0–2 at 3 months. Results: Eight hundred thirty-six patients with a final mTICI ⩾ 2b were included in this analysis. FPE was observed in 302 patients (36.1%). In multivariable analysis, hypertension (aOR 1.55, 95% CI 1.10–2.20) and lower baseline NIHSS score (aOR 0.95, 95% CI 0.93–0.97) were independently associated with an FPE. Good outcomes were more common in the FPE versus non-FPE group (72.8% vs 52.8%), and FPE was independently associated with favorable outcome (aOR 2.20, 95% CI 1.59–3.05). 90-day mortality and intracranial hemorrhage (ICH) were significantly lower in the FPE group, 0.43 (95% CI, 0.25–0.72) and 0.55 (95% CI, 0.39–0.77), respectively. Conclusion: Over 2/3 of patients with MeVOs and FPE in our cohort had a favorable outcome at 90 days. FPE is independently associated with favorable outcomes, it may reduce the risk of any intracranial hemorrhage, and 3-month mortality.
Aspiration Versus Stent‐Retriever as First‐Line Endovascular Therapy Technique for Primary Medium and Distal Intracranial Occlusions: A Propensity‐Score Matched Multicenter Analysis

Stroke: Vascular and Interventional Neurology | July 6, 2023 | Volume: 3 | Issue: 6 | Pages: No page available

10.1161/svin.123.000931 | PMID 41585056

Background For acute proximal intracranial artery occlusions, contact aspiration may be more effective than stent‐retriever for first‐line reperfusion therapy. Due to the lack of data regarding medium vessel occlusion thrombectomy, we evaluated outcomes according to first‐line technique in a large, multicenter registry. Methods Imaging, procedural, and clinical outcomes of patients with acute proximal medium vessel occlusions (M2, A1, or P1) or distal medium vessel occlusions (M3, A2, P2, or further) treated at 37 sites in 10 countries were analyzed according to first‐line endovascular technique (stent‐retriever versus aspiration). Multivariable logistic regression and propensity‐score matching were used to estimate the odds of the primary outcome, expanded Thrombolysis in Cerebral Infarction score of 2b–3 (“successful recanalization”), as well as secondary outcomes (first‐pass effect, expanded Thrombolysis in Cerebral Infarction 2c‐3, intracerebral hemorrhage, and 90‐day modified Rankin scale, 90‐day mortality) between treatment groups. Results Of the 440 included patients (44.5% stent‐retriever versus 55.5% aspiration), those treated with stent‐retriever had lower baseline Alberta Stroke Program Early Computed Tomography Scale scores (median 8 versus 9; P <0.01), higher National Institutes of Health Stroke Scale scores (median 13 versus 11; P =0.02), and nonsignificantly fewer medium‐distal occlusions (M3, A2, P2, or other: 17.4% versus 23.8%; P =0.10). Use of a stent‐retriever was associated with 15% lower odds of successful recanalization (odds ratio [OR], 0.85; [95% CI 0.74–0.98]; P =0.02), but this was not significant after multivariable adjustment in the total cohort (adjusted OR, 0.88; [95% CI 0.72–1.09]; P =0.24), or in the propensity‐score matched cohort (n=105 in each group) (adjusted OR, 0.94; [95% CI 0.75–1.18]; P =0.60). There was no significant association between technique and secondary outcomes in the propensity‐score matched adjusted models. Conclusion In this large, diverse, multinational medium vessel occlusion cohort, we found no significant difference in imaging or clinical outcomes with aspiration versus stent‐retriever thrombectomy.
Abstract Number ‐ 7: Final Angiographic, Clinical and Thrombus Composition Results of 1000 Patients in the EXCELLENT Registry

Stroke: Vascular and Interventional Neurology | April 25, 2023 | Volume: 3 | Issue: S1 | Pages: No page available

10.1161/svin.03.suppl_1.007

Introduction EXCELLENT (NCT03685578; Cerenovus) is a large, prospective, international, real‐world registry of endovascular clot removal in acute ischemic stroke (AIS) with EmboTrap as the first line mechanical thrombectomy (MT) device, which included collection and analysis of the retrieved thrombus material. Methods Between September 2018 and March 2021, 1000 “all‐comer” patients were enrolled at 34 global sites (27 US, 5 EU, 1 UK, 1 Israel) and treated according to standard of care at each center (with Embrotrap as first line). The study employed blind endpoint evaluation, including a core imaging lab and an independent 90‐day mRS assessment. Retrieved clot was collected per each MT maneuver from 538 subjects across 26 sites and clot analysis was performed by independent central labs blinded to clinical data. Results mITT population included 998 subjects. Mean age was 69.9±14.18 years (range 18–102), 51.8% (517/998) subjects were female and 9.9% (97/997) had a pre‐stroke mRS 3–5. Baseline NIHSS was 15.6±6.87 (range 0–36); 10.1% (82/815) subjects had a large core (ASPECTS 0–5); 5.8% (57/990) had posterior stroke; 56.3% (523/929) underwent MT ≤ 6hrs of onset and 38.1% (380/998) received IV‐tPA prior to MT. First pass eTICI 2c‐3 was achieved in 38.3% (377/984) and final 2b‐3 in 94.5 % (930/984; median number of passes = 1) of subjects. 90‐day mRS≤2 or ≤pre‐stroke was 46.9% (429/915) and 90‐day all‐cause mortality was 19.0% (175/921). The univariate analysis of clot components showed high red blood cell and low platelet content were significant predictors of good mRS outcome (p < 0.001 and 0.009) and negative predictors of 90‐day mortality (p < 0.001 and 0.017, respectively). Conclusions This large multi‐center, all‐comer cohort reflects the population undergoing thrombectomy today in a real world‐setting. Final angiographic, clinical and thrombus composition results, along with multivariate analysis of predictors of clinical outcomes, will be presented at the time of the conference.
Abstract WMP87: Primary Results From The CLEAR Study Of The Safety And Effectiveness Of The Neva Stent Retriever For Large Vessel Thrombectomy

Stroke | February 2, 2023 | Volume: 54 | Issue: Suppl_1 | Pages: No page available

10.1161/str.54.suppl_1.wmp87

Despite the proven benefit of stent retrievers, challenges to rapid revascularization of large vessel occlusions (LVO) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed with openings in the basket cell structure (“drop zones”) intended to capture organized thrombi within the central scaffold during retrieval. Prospective, multicenter, open label, single arm, FDA-regulated IDE study to evaluate the performance of the NeVa device for recanalizing occluded intracranial vessels including ICA, M1/M2 MCA, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of eTICI 2b-3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a margin of -10%. Additional efficacy endpoints included first pass effect to eTICI 2b-3 (FPE) and 90-day mRS 0-2. Primary safety endpoint was 90-day mortality. (ClinicalTrials.gov NCT04514562) (Site-adjudicated revascularization results are reported here. Final core lab results will be presented at the conference.) From April 1, 2021 to April 28, 2022, 139 subjects were enrolled at 25 centers in the US and Europe. Mean age was 67 ± 13 years; 47% were female. Median NIHSS score was 16 (IQR: 12-20). Occlusions were 14 (10%) ICA, 85 (61%) M1, 38 (27%) M2, 1 (1%) Basilar and 1 (1%) PCA. Mean time to first pass was 19 ± 12 minutes. eTICI 2b-3 within 3 NeVa passes occurred in 87.8% (122/139; CI 81.1%,92.7%; non-inferiority p<0.0001; post hoc superiority p=0.002, tested against performance goal of 72%). FPE (to eTICI 2b-3) was observed in 67.6% (94/139), with first pass to eTICI 2b67-3 in 61.2% (85/139) and to eTICI 2c-3 in 43.9% (61/139). Median number of passes was 1 (IQR 1-2). Final eTICI 2b-3 rate was 94.2% (131/139); final eTICI 2c-3 rate was 65.5% (91/139). Good outcome (90-day mRS 0-2) was seen in 62.6% (87/139) and was 74.4% in patients with FPE (70/94 vs. 17/45 (37.8%) without FPE; p<0.0001). Mortality was 9.4% (13/139) with sICH in 8 (5.8%) subjects. The NeVa device is effective and safe for revascularization of LVO strokes and demonstrates high first pass success in this international multicenter study. First pass reperfusion (eTICI 2b-3) was strongly associated with functional independence.
Abstract 28: First Pass Outcomes And Associated Clot Characteristics: Secondary Analysis Of The Excellent Registry

Stroke | February 2, 2023 | Volume: 54 | Issue: Suppl_1 | Pages: No page available

10.1161/str.54.suppl_1.28

Introduction: EXCELLENT (NCT03685578) is a global prospective, multicenter, real-world registry of mechanical thrombectomy for stroke with the EmboTrap device as first line treatment which includes clot collection and analysis. Aim of the study: To report the rates of clinical outcomes and clot characteristics associated with first pass reperfusion in EXCELLENT. Methods: Per pass angiographic outcomes assessed by an independent core lab were available in 984 subjects Analysis of clot from 538 cases was performed by independent central labs blinded to clinical data. 90-day mRS assessment was blinded to subject data. Results: First pass reperfusion of mTICI 2b-3 (63.2%) and 2c-3 (38.3%) was significantly predictive of mRS 0-2 or ≤pre-stroke (p=0.011 and p=0.016) but not all-cause mortality at 90 days (p=0.080 and p=0.123, respectively). Further, mTICI 2c-3 in one pass was associated with a higher rate of mRS 0-2 or ≤pre-stroke vs. mTICI 2c-3 reperfusion in >1 pass, (55.5% and 45.1%, respectively, p=0.013) and a rate of all-cause mortality at 90 days of 14.6% vs. 19.8% (p=0.097). Full patient characteristics and clinical outcomes are shown in Table 1. Notable clot composition findings included: RBC (%, mean±SD): mTICI 2c-3, 1 pass 47.69±22.25, mTICI 2c-3, >1 pass 43.86±19.05, (p=0.088); fibrin: mTICI 2c-3, 1 pass 23.20±13.80, mTICI 2c-3 >1 pass 25.40 ± 13.52 (p=0.131); von Willebrand factor (VWF): mTICI2c-3, 1 pass 16.09±14.62, mTICI 2c-3, >1 pass 19.42±17.15 (p=0.038). Conclusions: First pass reperfusion in the EXCELLENT registry was associated with better clinical outcomes at 90 days. Clots retrieved with first pass reperfusion had higher RBC and lower fibrin and VWF content compared to those who achieved reperfusion at greater than one pass.