Citations 219

Radiosurgery and immune checkpoint inhibition in the treatment of brain metastases: A meta-analysis of patient-level data.

Journal of Clinical Oncology | September 5, 2018 | Volume: 36 | Issue: 15_suppl | Pages: e14009-e14009

10.1200/jco.2018.36.15_suppl.e14009

HIV-1 Envelope Protein gp120 Promotes Proliferation and the Activation of Glycolysis in Glioma Cell

Cancers | September 3, 2018 | Volume: 10 | Issue: 9 | Pages: 301

10.3390/cancers10090301 | PMID 30200472

Patients infected with human immunodeficiency virus (HIV) are more prone to developing cancers, including glioblastomas (GBMs). The median survival for HIV positive GBM patients is significantly shorter than for those who are uninfected, despite the fact that they receive the same treatments. The nature of the GBM–HIV association remains poorly understood. In this study, we analyzed the effect of the HIV envelope glycoprotein gp120 on GBM cell proliferation. Specifically, we performed cell cycle, western blot, protein synthesis and metabolomics analysis as well as ATP production and oxygen consumption assays to evaluate proliferation and metabolic pathways in primary human glioma cell line, U87, A172 cells and in the HIVgp120tg/GL261 mouse model. Glioma cells treated with gp120 (100 ng/mL for 7–10 days) showed higher proliferation rates and upregulation in the expression of enolase 2, hexokinase and glyceraldehyde-3-phosphate dehydrogenase when compared to untreated cells. Furthermore, we detected an increase in the activity of pyruvate kinase and a higher glycolytic index in gp120 treated cells. Gp120 treated GBM cells also showed heightened lipid and protein synthesis. Overall, we demonstrate that in glioma cells, the HIV envelope glycoprotein promotes proliferation and activation of glycolysis resulting in increased protein and lipid synthesis.
Mimicking Human Pathophysiology in Organ‐on‐Chip Devices

Advanced Biosystems | August 14, 2018 | Volume: 2 | Issue: 10 | Pages: No page available

10.1002/adbi.201800109

AbstractConvergence of life sciences, engineering, and basic sciences has opened new horizons for biologically inspired innovations, and a considerable number of organ‐on‐a‐chip platforms have been developed for mimicking physiological systems of biological organs such as the brain, heart, lung, kidney, liver, and gut. Various biophysicochemical factors can also be introduced into such organ‐on‐a‐chip platforms to study metabolic and systemic effects spanning from drug toxicity to different pathologic manifestations. There is also a pressing need to develop better disease models for common pathologies using variations of these platforms. This can be achieved by recapitulating the unique microenvironment of a disease to investigate the cause and development of abnormal conditions as well as the structural and functional changes resulting from such a pathology. In this review, the organ‐on‐a‐chip platforms that have been developed to model different pathologies of neurodegenerative, cardiovascular, respiratory, hepatic, and digestive systems, along with cancer are summarized. Although the field is still in its infancy, it is anticipated that developing disease model‐on‐a‐chip platforms will likely be a valuable addition to the field of disease modeling, pathology studies, and improved drug discovery.
Extending the resection beyond the contrast-enhancement for glioblastoma: feasibility, efficacy, and outcomes

British Journal of Neurosurgery | August 3, 2018 | Volume: 32 | Issue: 5 | Pages: 528-535

10.1080/02688697.2018.1498450 | PMID 30073866

Retractorless Surgery: Strokes, Edema, and Gliosis Outcomes Following Skull Base Surgery

Journal of Neurological Surgery Part B: Skull Base | July 13, 2018 | Volume: 79 | Issue: S 01 | Pages: S1-S188

10.1055/s-0038-1633350

Intraoperative Seizures in Awake Craniotomy for Perirolandic Glioma Resections That Undergo Cortical Mapping

Journal of Neurological Surgery Part A: Central European Neurosurgery | July 13, 2018 | Volume: 79 | Issue: 03 | Pages: 239-246

10.1055/s-0037-1617759 | PMID 29346829

Background Perirolandic motor area gliomas present invasive eloquent region tumors within the precentral gyrus that are difficult to resect without causing neurologic deficits. Study Aims This study evaluates the role of awake craniotomy and motor mapping on neurologic outcome and extent of resection (EOR) of tumor in the perirolandic motor region. It also analyzes preoperative risk factors for intraoperative seizures. Methods We evaluated 57 patients who underwent an awake craniotomy for a perirolandic motor area eloquent region glioma. Patients who had positive mapping (PM) or intraoperative identification of motor regions in the cortex using direct cortical stimulation were compared with patients with no positive motor mapping following direct cortical stimulation and negative mapping (NM). Preoperative risks, intraoperative seizures, perioperative outcomes, tumor characteristics, and EOR were also compared. A logistic regression model was used to evaluate the predictors for intraoperative seizures in this patient cohort. Results Overall, 33 patients were in the PM cohort; 24 were in the NM cohort. Our study showed an 8.8% incidence of intraoperative seizures during cortical and subcortical mapping for awake craniotomies in the perirolandic motor area, none of which aborted the case. PM patients had significantly more intraoperative and postoperative seizures (15.5% and 30.3%, respectively) compared with the NM patients (0% and 8.3%, respectively; p = 0.046 and 0.044). New transient postoperative motor deficits were found more often in the PM group (51.5%) versus the NM group (12.5%; p = 0.002). A univariate logistic regression showed that PM (odds ratio [OR]: 1.16; 95% confidence interval [CI], 1.01–1.34; p = 0.035) and preoperative tumor volume (OR: 0.998; 95% CI, 0.996–0.999; p = 0.049) were significant predictors for intraoperative seizures in patients with perirolandic gliomas. Conclusion Awake craniotomies in the perirolandic motor region can be safely performed with a similar incidence of intraoperative seizures as reported for the language cortex. PM in this region may increase the likelihood of perioperative seizures or motor deficits compared with NM. Craniotomies that minimize cortical exposure for perirolandic gliomas that may not localize motor regions can still allow for extensive tumor resection with a good postoperative outcome.
Verteporfin-Loaded Poly(ethylene glycol)-Poly(beta-amino ester)-Poly(ethylene glycol) Triblock Micelles for Cancer Therapy

Biomacromolecules | June 25, 2018 | Volume: 19 | Issue: 8 | Pages: 3361-3370

10.1021/acs.biomac.8b00640 | PMID 29940101

Abstract Amphiphilic polymers can be used to form micelles to deliver water-insoluble drugs. A biodegradable poly­(ethylene glycol) (PEG)-poly­(beta-amino ester) (PBAE)-PEG triblock copolymer was developed that is useful for drug delivery. It was shown to successfully encapsulate and pH-dependently release a water-insoluble, small molecule anticancer drug, verteporfin. PEG-PBAE-PEG micelle morphology was also controlled through variations to the hydrophobicity of the central PBAE block of the copolymer in order to evade macrophage uptake. Spherical micelles were 50 nm in diameter, while filamentous micelles were 31 nm in width with an average aspect ratio of 20. When delivered to RAW 264.7 mouse macrophages, filamentous micelles exhibited a 89% drop in cellular uptake percentage and a 5.6-fold drop in normalized geometric mean cellular uptake compared to spherical micelles. This demonstrates the potential of high-aspect-ratio, anisotropically shaped PEG-PBAE-PEG micelles to evade macrophage-mediated clearance. Both spherical and filamentous micelles also showed therapeutic efficacy in human triple-negative breast cancer and small cell lung cancer cells without requiring photodynamic therapy to achieve an anticancer effect. Both spherical and filamentous micelles were more effective in killing lung cancer cells than breast cancer cells at equivalent verteporfin concentrations, while spherical micelles were shown to be more effective than filamentous micelles against both cancer cells. Spherical and filamentous micelles at 5 and 10 μM respective verteporfin concentration resulted in 100% cell killing of lung cancer cells, but both micelles required a higher verteporfin concentration of 20 μM to kill breast cancer cells at the levels of 80% and 50% respectively. This work demonstrates the potential of PEG-PBAE-PEG as a biodegradable, anisotropic drug delivery system as well as the in vitro use of verteporfin-loaded micelles for cancer therapy.
Endoscope-assisted contralateral transmaxillary approach to the clivus and the hypoglossal canal: technical case report

Journal of Neurosurgery | June 22, 2018 | Volume: No volume available | Issue: No issue available | Pages: 1-7

10.3171/2018.1.jns171972 | PMID 29932381

Clival lesions are still considered surgically complex due to their anatomical location. Critical structures, such as the internal carotid arteries (ICAs), cavernous sinuses, cranial nerves, and brainstem, may be encased within the lesion. Although advances in endoscopic endonasal approaches have provided new routes to these lesions, exposure and resection of clival tumors through the endonasal route remain a technical challenge. Here, the authors report a left-sided endoscopic transmaxillary approach to access the right aspect of the clivus and the hypoglossal canal. A 35-year-old woman presented with progressive right 6th cranial nerve palsy. MRI revealed a contrast-enhancing right petroclival chondrosarcoma that involved Meckel’s cave and extended into the right hypoglossal canal. An endoscopic-contralateral-transmaxillary approach through a left sublabial incision was used to access the right petroclival region and right hypoglossal canal. A left maxillary osteoplastic flap was elevated to expose the left maxillary sinus. This was followed by a left medial maxillectomy, gaining access to the left posterior nasal cavity. The posterior third of the left inferior turbinate and nasal septum were removed to access the right side of the petroclival region. Near-total resection was achieved without any vascular or neurological complications. A thin shell of residual tumor was left behind due to involvement of vital structures, such as the ICA, and further treated with proton-beam radiotherapy. The endoscopic-contralateral-transmaxillary approach provides a direct surgical corridor and good lateral visualization of the skull base vasculature. This approach allows wide maneuverability around the ICA and hypoglossal canal, which, in this case, allowed maximal tumor resection with full preservation of neurological function.
Surgical treatment of bilateral glossopharyngeal neuralgia

International Journal of Neuroscience | June 11, 2018 | Volume: 128 | Issue: 12 | Pages: 1204-1206

10.1080/00207454.2018.1486308 | PMID 29888997

Augmented reality for the surgeon: Systematic review

The International Journal of Medical Robotics and Computer Assisted Surgery | April 30, 2018 | Volume: 14 | Issue: 4 | Pages: No page available

10.1002/rcs.1914 | PMID 29708640

AbstractIntroductionSince the introduction of wearable head‐up displays, there has been much interest in the surgical community adapting this technology into routine surgical practice.MethodsWe used the keywords augmented reality OR wearable device OR head‐up display AND surgery using PubMed, EBSCO, IEEE and SCOPUS databases. After exclusions, 74 published articles that evaluated the utility of wearable head‐up displays in surgical settings were included in our review.ResultsAcross all studies, the most common use of head‐up displays was in cases of live streaming from surgical microscopes, navigation, monitoring of vital signs, and display of preoperative images. The most commonly used head‐up display was Google Glass. Head‐up displays enhanced surgeons' operating experience; common disadvantages include limited battery life, display size and discomfort.ConclusionsDue to ergonomic issues with dual‐screen devices, augmented reality devices with the capacity to overlay images onto the surgical field will be key features of next‐generation surgical head‐up displays.