Objectives: The objectives of the study were to estimate the impact of high matrix image reconstruction on chest computed tomography (CT) compared to standard image reconstruction. Material and Methods: This retrospective study included patients with interstitial or parenchymal lung disease, airway disease, and pulmonary nodules who underwent chest CT. Chest CT images were reconstructed using high matrix (1024 × 1024) or standard matrix (512 × 512), with all other parameters matched. Two radiologists, blinded to reconstruction technique, independently examined each lung, viewing image sets side by side and rating the conspicuity of imaging findings using a 5-point relative conspicuity scale. The presence of pulmonary nodules and confidence in classification of internal attenuation was also graded. Overall image quality and subjective noise/artifacts were assessed. Results: Thirty-four patients with 68 lungs were evaluated. Relative conspicuity scores were significantly higher using high matrix image reconstruction for all imaging findings indicative of idiopathic lung fibrosis (peripheral airway visualization, interlobular septal thickening, intralobular reticular opacity, and end-stage fibrotic change; P ≤ 0.001) along with emphysema, mosaic attenuation, and fourth order bronchi for both readers (P ≤ 0.001). High matrix reconstruction did not improve confidence in the presence or classification of internal nodule attenuation for either reader. Overall image quality was increased but not subjective noise/artifacts with high matrix image reconstruction for both readers (P < 0.001). Conclusion: High matrix image reconstruction significantly improves the conspicuity of imaging findings reflecting interstitial lung disease and may be useful for diagnosis or treatment response assessment.
An interactive eye‐tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye‐tracking accuracy validation
Medical Physics | September 17, 2021 | Volume: 48 | Issue: 11 | Pages: 6710-6723
AbstractPurposeEye‐tracking approaches have been used to understand the visual search process in radiology. However, previous eye‐tracking work in computer tomography (CT) has been limited largely to single cross‐sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three‐dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye‐tracking hardware with in‐house‐developed reader workstation software to allow monitoring of the visual search process and reader‐image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye‐tracking data using this platform for different eye‐tracking data acquisition modes.MethodsAn eye‐tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real‐time eye movement and workstation events at 1000 Hz sampling frequency. The eye‐tracker was operated either in head‐stabilized mode or in free‐movement mode. In head‐stabilized mode, the reader positioned their head on a manufacturer‐provided chinrest. In free‐movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye‐tracking spatial accuracy under three constraint conditions: head‐stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross‐hair target prior to the integration of the eye‐tracker with the image viewing workstation. In Study 2, after integration of the eye‐tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.ResultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye‐tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.ConclusionsAn integrated eye‐tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head‐free movement condition with audio biofeedback performed similarly to head‐stabilized mode.
CT Noise-Reduction Methods for Lower-Dose Scanning: Strengths and Weaknesses of Iterative Reconstruction Algorithms and New Techniques
Background Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. Purpose To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. Materials and Methods Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). Results 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images ( p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images ( p = 0.006, p = 0.018). Conclusion A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.
Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience
Physics in Medicine & Biology | July 16, 2021 | Volume: 66 | Issue: 20 | Pages: 205019
Abstract We report a comprehensive evaluation of a full field-of-view (FOV) photon-counting detector (PCD) computed tomography (CT) system using phantoms, and qualitatively assess image quality in patient examples. A whole-body PCD-CT system with 50 cm FOV, 5.76 cm z-detector coverage and two acquisition modes (standard: 144 × 0.4 mm collimation and ultra-high resolution (UHR): 120 × 0.2 mm collimation) was used in this study. Phantoms were scanned to assess image uniformity, CT number accuracy, noise power spectrum, spatial resolution, material decomposition and virtual monoenergetic imaging (VMI) performance. Four patients were scanned on the PCD-CT system with matched or lower radiation dose than their prior clinical CT scans performed using energy-integrating detector (EID) CT, and the potential clinical impact of PCD-CT was qualitatively evaluated. Phantom results showed water CT numbers within ±5 HU, and image uniformity measured between peripheral and central regions-of-interests to be within ±5 HU. For the UHR mode using a dedicated sharp kernel, the cut-off spatial frequency was 40 line-pairs cm −1 , which corresponds to a 125 μ m limiting in-plane spatial resolution. The full-width-at-half-maximum for the section sensitivity profile was 0.33 mm for the smallest slice thickness (0.2 mm) using the UHR mode. Material decomposition in a multi-energy CT phantom showed accurate material classification, with a root-mean-squared-error of 0.3 mg cc −1 for iodine concentrations (2–15 mg cc −1 ) and 14.2 mg cc −1 for hydroxyapatite concentrations (200 and 400 mg cc −1 ). The average percent error for CT numbers corresponding to the iodine concentrations in VMI (40–70 keV) was 2.75%. Patient PCD-CT images demonstrated better delineation of anatomy for chest and temporal bone exams performed with the UHR mode, which allowed the use of very sharp kernels not possible with EID-CT. VMI and virtual non-contrast images generated from a patient head CT angiography exam using the standard acquisition mode demonstrated the multi-energy capability of the PCD-CT system.
International consensus to standardise histopathological scoring for small bowel strictures in Crohn’s disease
Gut | May 5, 2021 | Volume: 71 | Issue: 3 | Pages: 479-486
Objective Effective medical therapy and validated trial outcomes are lacking for small bowel Crohn’s disease (CD) strictures. Histopathology of surgically resected specimens is the gold standard for correlation with imaging techniques. However, no validated histopathological scoring systems are currently available for small bowel stricturing disease. We convened an expert panel to evaluate the appropriateness of histopathology scoring systems and items generated based on panel opinion. Design Modified RAND/University of California Los Angeles methodology was used to determine the appropriateness of 313 candidate items related to assessment of CD small bowel strictures. Results In this exercise, diagnosis of naïve and anastomotic strictures required increased bowel wall thickness, decreased luminal diameter or internal circumference, and fibrosis of the submucosa. Specific definitions for stricture features and technical sampling parameters were also identified. Histopathologically, a stricture was defined as increased thickness of all layers of the bowel wall, fibrosis of the submucosa and bowel wall, and muscularisation of the submucosa. Active mucosal inflammatory disease was defined as neutrophilic inflammation in the lamina propria and any crypt or intact surface epithelium, erosion, ulcer and fistula. Chronic mucosal inflammatory disease was defined as crypt architectural distortion and loss, pyloric gland metaplasia, Paneth cell hyperplasia, basal lymphoplasmacytosis, plasmacytosis and fibrosis, or prominent lymphoid aggregates at the mucosa/submucosa interface. None of the scoring systems used to assess CD strictures were considered appropriate for clinical trials. Conclusion Standardised assessment of gross pathology and histopathology of CD small bowel strictures will improve clinical trial efficiency and aid drug development.
Challenges in Diagnosis and Management of Hemobilia
Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Low‐dose CT image and projection dataset
Medical Physics | November 17, 2020 | Volume: 48 | Issue: 2 | Pages: 902-911
Purpose To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. Acquisition and Validation Methods The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low‐dose noncontrast chest scans acquired to screen high‐risk patients for pulmonary nodules, and contrast‐enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise‐insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. Data Format and Usage Notes Projection datasets were converted into the previously developed DICOM‐CT‐PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM‐CT‐PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive ( https://doi.org/10.7937/9npb‐2637 ). Potential Applications This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task‐based diagnostic performance.