Citations 159

A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101321R

10.1117/12.2255593 | PMID 28392614

A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
MR Imaging of Perianal Crohn Disease

Radiology | February 28, 2017 | Volume: 282 | Issue: 3 | Pages: 628-645

10.1148/radiol.2016151491 | PMID 28218881

Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality

American Journal of Roentgenology | February 22, 2017 | Volume: 208 | Issue: 3 | Pages: 552-563

10.2214/ajr.16.16613 | PMID 28225687

Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction

Magnetic Resonance in Medicine | February 2, 2017 | Volume: 78 | Issue: 6 | Pages: 2203-2215

10.1002/mrm.26620 | PMID 28150873

PurposeThe purpose of this work is to derive and demonstrate constrained‐phase dual‐echo Dixon imaging within a maximum likelihood framework solved with a regularized graph‐cuts‐guided optimization.Theory and MethodsDual‐echo Dixon reconstruction is fundamentally underdetermined; however, adopting a constrained‐phase signal model reduces the number of unknowns and the nonlinear problem can be solved under a maximum likelihood framework. Period shifts in the field map (manifesting as fat/water signal swaps) must also be corrected. Here, a regularized cost function promotes a smooth field map and is solved with a graph‐cuts‐guided greedy binary optimization. The reconstruction shown here is compared to two other prevalent Dixon reconstructions in experimental phantom and human studies.ResultsReconstructed images of the water and fat signal are shown for a phantom study, and in vivo studies of foot/ankle, pelvis, and CE‐MRA of the thighs. The method shown here compared favorably with the other two methods. Large field inhomogeneities on the order of 20 ppm were resolved, thereby avoiding the fat and water signal swaps present in images reconstructed with the other methods.ConclusionConstrained‐phase dual‐echo Dixon imaging solved with a regularized graph‐cuts‐guided optimization has been derived and demonstrated to successfully separate water and fat images in the presence of large magnetic field inhomogeneities. Magn Reson Med 78:2203–2215, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
First PET Imaging Studies With 63 Zn-Zinc Citrate in Healthy Human Participants and Patients With Alzheimer Disease

Molecular Imaging | December 10, 2016 | Volume: 15 | Issue: No issue available | Pages: No page available

10.1177/1536012116673793 | PMID 27941122

Abnormalities in zinc homeostasis are indicated in many human diseases, including Alzheimer disease (AD). 63 Zn-zinc citrate was developed as a positron emission tomography (PET) imaging probe of zinc transport and used in a first-in-human study in 6 healthy elderly individuals and 6 patients with clinically confirmed AD. Dynamic PET imaging of the brain was performed for 30 minutes following intravenous administration of 63 Zn-zinc citrate (∼330 MBq). Subsequently, body PET images were acquired. Urine and venous blood were analyzed to give information on urinary excretion and pharmacokinetics. Regional cerebral 63 Zn clearances were compared with 11 C-Pittsburgh Compound B ( 11 C-PiB) and 18 F-fluorodeoxyglucose ( 18 F-FDG) imaging data. 63 Zn-zinc citrate was well tolerated in human participants with no adverse events monitored. Tissues of highest uptake were liver, pancreas, and kidney, with moderate uptake being seen in intestines, prostate (in males), thyroid, spleen, stomach, pituitary, and salivary glands. Moderate brain uptake was observed, and regional dependencies were observed in 63 Zn clearance kinetics in relationship with regions of high amyloid-β plaque burden ( 11 C-PiB) and 18 F-FDG hypometabolism. In conclusion, zinc transport was successfully imaged in human participants using the PET probe 63 Zn-zinc citrate. Primary sites of uptake in the digestive system accent the role of zinc in gastrointestinal function. Preliminary information on zinc kinetics in patients with AD evidenced regional differences in clearance rates in correspondence with regional amyloid-β pathology, warranting further imaging studies of zinc homeostasis in patients with AD.
Evaluation of Patient Tolerance and Small-Bowel Distention With a New Small-Bowel Distending Agent for Enterography

American Journal of Roentgenology | March 21, 2016 | Volume: 206 | Issue: 5 | Pages: 994-1002

10.2214/ajr.15.15260 | PMID 26998661

Characterization of Urinary Stone Composition by Use of Third-Generation Dual-Source Dual-Energy CT With Increased Spectral Separation

American Journal of Roentgenology | November 20, 2015 | Volume: 205 | Issue: 6 | Pages: 1203-1207

10.2214/ajr.15.14348 | PMID 26587926

Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method

American Journal of Roentgenology | October 24, 2015 | Volume: 205 | Issue: 5 | Pages: 1026-1037

10.2214/ajr.14.14185 | PMID 26496550

CT Colonography for the Detection of Nonpolypoid Adenomas: Sensitivity Assessed With Restricted National CT Colonography Trial Criteria

American Journal of Roentgenology | November 21, 2014 | Volume: 203 | Issue: 6 | Pages: W614-W622

10.2214/ajr.13.12356 | PMID 25415726