Citations 81

EP6.38 Outpatient Periacetabular Osteotomy: Common Clinical Fact or Insurance Fiction?

Journal of Hip Preservation Surgery | March 31, 2025 | Volume: 12 | Issue: Supplement_1 | Pages: i101-i102

10.1093/jhps/hnaf011.327

Abstract Introduction: Periacetabular osteotomy (PAO) is a complex procedure historically requiring inpatient stay. There is increased emphasis for these to be performed on an outpatient basis by insurance companies. The purpose of this study was to investigate the proportion of various surgical listing classifications (outpatient, outpatient-overnight, inpatient), the incidence of subsequent denial/request for additional documentation for approval of inpatient stay, and to characterize the average length of stay (LOS) following PAO. Methods: A retrospective chart review was performed to identify all PAOs, performed by four participating surgeons, at a single academic institution over a two-year period. The initial listing status as an outpatient-overnight or inpatient procedure was identified. Whether a preoperative peer review was required for approval of inpatient listings as well as if additional documentation was necessary to convert outpatient-overnight listings to inpatient stays were also recorded. Results: A total of 140 PAOs amongst 117 patients were performed with 25 (17.9%) initially listed as an inpatient stay and 115 (82.1%) listed as outpatient-overnight. Of the 25 PAOs listed as inpatient, 2 (8.0%) required a preoperative peer review process to justify or clarify listing status. The average LOS was 1.9 ± 1.4 days with 55.7% (78/140) of PAOs staying two or more nights in the hospital. Only 6 PAOs (4.3%) went home the same day as surgery. Of the 115 PAOs listed as an outpatient-overnight, 53 (46.1%) converted to an inpatient stay. Conclusion: Over half of PAOs performed required inpatient stay beyond outpatient-overnight status. Preoperative peer-to-peer review for inpatient stay approval was modestly frequent (8% of inpatient listings), and all conversions to inpatient required additional service documentation to support status conversion. Understanding trends in postoperative hospitalizations and LOS might allow for better informed partnerships between surgeons and insurance companies creating more efficient pre-authorizations, billing practices, and expected patterns of patient care and discharge.
Prospective Noninvasive Hemoglobin Monitoring in the Outpatient Total Joint Arthroplasty Setting

Journal of Bone and Joint Surgery | December 20, 2024 | Volume: 107 | Issue: 4 | Pages: 364-371

10.2106/jbjs.24.00438 | PMID 39705371

Background: Total joint arthroplasty (TJA) is increasingly being performed as an outpatient (i.e., same-day discharge) procedure. Postoperatively, orthostatic hypotension or pain-related tachycardia can lead to concerns regarding the hemoglobin (Hgb) level of the patient prior to discharge. The purpose of this study was to prospectively assess the reliability and accuracy of, and patient and nurse satisfaction with, postoperative noninvasive hemoglobin (nHgb) monitoring compared with an invasive serum hemoglobin (iHgb) laboratory draw in the outpatient TJA setting. Methods: We prospectively enrolled 200 patients undergoing outpatient unilateral TJA, of whom 157 were ultimately included in our analysis (94 hips, 63 knees). Postoperatively, both nHgb and iHgb values were obtained at a mean of 36 minutes apart. Surveys were completed by patients and nurses. The strength of the agreement between the 2 Hgb monitoring methods was evaluated with use of the Bland-Altman 95% limits of agreement, concordance correlation coefficient (CCC), and intraclass correlation coefficient (ICC). Receiver operating characteristic curve analyses were performed to investigate the ability of nHgb monitoring to predict an iHgb of <11.2 g/dL (the 5th-percentile iHgb value). Results: The mean preoperative iHgb was 14.2 ± 1.1 g/dL. The mean postoperative iHgb and nHgb values were 13.3 ± 1.5 and 13.3 ± 1.2 g/dL, respectively. The Bland-Altman 95% limits of agreement were −3.2 and +3.1 g/dL, indicating that 95% of patients’ iHgb values are expected to fall between these limits relative to the nHgb value of the patient. The CCC and ICC were both 0.33. An nHgb cutoff value of <12.7 g/dL had 100% sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Patients reported less pain with the nHgb test than with the iHgb test (mean pain score, 0.0 versus 1.8; p < 0.001), and 97% of patients preferred the nHgb test. Following the nHgb test, 73% of responding patients and 83% of responding nurses were “somewhat more reassured” to “significantly more reassured” about same-day discharge. Conclusions: Routine nHgb testing can rapidly screen patients undergoing outpatient TJA for acute anemia prior to discharge. With an nHgb of <12.7 g/dL, there was perfect sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Most patients and nurses felt more reassured about same-day discharge after nHgb monitoring. Level of Evidence: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.
Aseptic Revision Total Hip Arthroplasty Using Modular Fluted Tapered Stems

Journal of Bone and Joint Surgery | June 27, 2024 | Volume: 106 | Issue: 16 | Pages: 1470-1478

10.2106/jbjs.23.00921 | PMID 38935701

Background: Modular fluted tapered (MFT) femoral components are frequently utilized in aseptic revision total hip arthroplasties (THAs). However, long-term follow-up has been limited. The purpose of this study was to update our prior series at long-term follow-up, with specific emphasis on implant survivorship, radiographic results, and complications in a large cohort of aseptic revision THAs using MFT stems. Methods: We retrospectively identified 515 aseptic femoral revisions performed with 2 MFT stem designs in the total joint registry of a single tertiary care academic institution from 1999 to 2013. Serial radiographs were reviewed for subsidence of >5 mm. The mean follow-up (and standard deviation) was 10 ± 5 years (range, 2 to 21 years). A competing risk model accounting for death was utilized. Results: The 15-year cumulative incidence of any revision was 12%. There were 57 revisions, 27 of which involved revision of the fluted tapered component (FTC). Dislocation (n = 19), periprosthetic joint infection (n = 15), and aseptic loosening of the FTC (n = 11) were the most common reasons for revision. The 15-year cumulative incidence of any reoperation was 16%. The 15-year cumulative incidences were 6% for any FTC revision and 2% for FTC revision for aseptic loosening. Stem subsidence of >5 mm occurred in 2% of unrevised cases, and all but 1 stem was stable at the most recent follow-up. Conclusions: This large series of MFT stems used in aseptic revision THAs had a 2% incidence of subsequent revision of the FTC for aseptic loosening at 15 years. Dislocation and infection were the most common reasons for any revision. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Modular fluted tapered stems in two-stage reimplantation of previously infected total hip arthroplasties

The Bone & Joint Journal | May 1, 2024 | Volume: 106-B | Issue: 5 Supple B | Pages: 125-132

10.1302/0301-620x.106b5.bjj-2023-0788.r2 | PMID 38688510

AimsUncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.MethodsWe identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.ResultsThe 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n = 25) and infection (n = 16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only two FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence ≥ 5 mm occurred in 2% of unrevised cases. All stems were radiologically stable at most recent follow-up. Mean Harris Hip Score was 69 (SD 20) at most recent follow-up.ConclusionThis series demonstrated that MFT components were durable and reliable in the setting of two-stage reimplantation THA for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily due to dislocation and recurrent PJI.Cite this article: Bone Joint J 2024;106-B(5 Supple B):125–132.
Contemporary Aseptic Revision Total Hip Arthroplasty in Patients ≤50 Years of Age

Journal of Bone and Joint Surgery | April 30, 2024 | Volume: 106 | Issue: 12 | Pages: 1108-1116

10.2106/jbjs.23.01467 | PMID 38687829

Background: There has been a paucity of long-term outcomes data on aseptic revision total hip arthroplasties (THAs) in the young adult population. The purpose of this study was to evaluate implant survivorship, complications, and clinical outcomes in a large cohort of contemporary aseptic revision THAs in patients ≤50 years of age at the time of the surgical procedure. Methods: We identified 545 aseptic revision THAs performed at a single academic institution from 2000 to 2020 in patients who were 18 to 50 years of age. Patients who underwent conversion THAs and patients with a history of any ipsilateral hip infection were excluded. The mean age was 43 years, the mean body mass index (BMI) was 29 kg/m 2 , and 63% were female. The index indication for revision THA was aseptic loosening in 46% of cases, polyethylene wear or osteolysis in 28% of cases (all revisions of conventional polyethylene), and dislocation in 11% of cases. There were 126 hips (23%) that had undergone at least 1 previous revision (median, 1 revision [range, 1 to 5 revisions]). The mean follow-up was 10 years. Results: In the entire cohort, the 20-year survivorship free of any re-revision was 76% (95% confidence interval [95% CI], 69% to 82%). There were 87 re-revisions, with 31 dislocations, 18 cases of aseptic loosening of the femoral component, and 16 periprosthetic joint infections (PJIs) being the most common reasons for re-revision. Dislocation as the indication for the index revision was associated with an increased risk of re-revision (hazard ratio, 2.9; p < 0.001). The 20-year survivorship free of any reoperation was 73% (95% CI, 66% to 78%). There were 75 nonoperative complications (14%), including 32 dislocations. The mean Harris hip score significantly improved (p < 0.001) from 65 preoperatively to 81 at 10 years postoperatively. Conclusions: Contemporary aseptic revision THAs in patients ≤50 years of age demonstrated a re-revision risk of approximately 1 in 4 at 20 years. Dislocation, aseptic loosening of the femoral component, and PJI were the most common reasons for re-revision. Index revision THAs for dislocation had a 3 times higher risk of re-revision. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Cemented dual-mobility constructs in uncemented revision acetabular components

The Bone & Joint Journal | April 1, 2024 | Volume: 106-B | Issue: 4 | Pages: 352-358

10.1302/0301-620x.106b4.bjj-2023-1061.r1 | PMID 38555941

AimsDislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.MethodsWe identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).ResultsThere were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case.ConclusionWhile dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface.Cite this article: Bone Joint J 2024;106-B(4):352–358.
Extended Trochanteric Osteotomy in Revision Total Hip Arthroplasty

JBJS Essential Surgical Techniques | August 10, 2023 | Volume: 13 | Issue: 3 | Pages: No page available

10.2106/jbjs.st.21.00003 | PMID 38282724

Background: Removal of well-fixed femoral components during revision total hip arthroplasty (THA) can be difficult and time-consuming 1 , leading to numerous complications, such as femoral perforation, bone loss, and fracture. Extended trochanteric osteotomies (ETOs), which provide wide exposure and direct access to the femoral canal under controlled conditions, have become a popular method to circumvent these challenges. ETOs were popularized by Wagner (i.e., the anterior-based osteotomy), and later modified by Paprosky (i.e., the lateral-based osteotomy) 2 . Description: The decision to utilize the laterally based Paprosky ETO versus the anteriorly based Wagner ETO is primarily based on surgeon preference, the location and type of in situ implants, and the osseous anatomy. Typically, a laterally based ETO is most facile in conjunction with a posterior approach and an anteriorly based ETO is most commonly paired with a lateral or anterolateral approach. Attention must be paid to maintaining vascularity to the osteotomy fragment, including minimizing stripping of the vastus lateralis from the osteotomy fragment and maintaining abductor attachments to the osteotomy fragment. When utilizing a laterally based ETO, the posterior border of the vastus lateralis must be carefully elevated to provide exposure for performance of the osteotomy. When an anteriorly based osteotomy is performed, the surgeon may instead extend the abductor tenotomy proximally with use of a longitudinal split of the vastus lateralis distally, which helps to keep the anterior and posterior sleeves of soft tissue in continuity. In either approach, dissection of the vastus lateralis involves managing several large vascular perforators. We prefer performing careful blunt dissection to identify the perforators and prophylactically controlling them, with ligation of large vessels and electrocautery of smaller vessels. Vascular clips are also available in case difficult-to-control bleeding is encountered. In general, an oscillating saw (with preference for a thin blade) is utilized to complete the posterior longitudinal limb of the ETO, extending approximately 12 to 16 cm distally from the tip of the greater trochanter. Although a 12 to 16-cm zone is required to maintain maximum vascularity to the osteotomized fragment, the osteotomy length must ultimately be determined by (1) the length of the femoral component to be removed; (2) the presence of distal bone ingrowth, ongrowth, or cement; and (3) the presence of distal hardware or stemmed knee components. A smaller oscillating saw is then utilized to complete the transverse limb at the previously identified distal extent. A high-speed pencil-tip burr is utilized to complete the corners of the osteotomy in a rounded configuration, and a combination of saws and pencil-tip burrs is utilized to create partial proximal and distal anterior longitudinal limbs of the osteotomy to the extent allowed by the soft-tissue attachments. The anterior longitudinal limb may be further weakened in a controlled fashion with use of serial drill holes. The anterior longitudinal limb then undergoes controlled fracture by placement of 2 to 4 broad straight osteotomes in the posterior longitudinal limb. These osteotomes are carefully levered anteriorly in unison with a gentle, steady force. After the ETO is completed, intramedullary prostheses, hardware, and cement are removed; the acetabulum is addressed as needed; and a final femoral stem is implanted, if appropriate. After completion of the osteotomy, the osteotomized fragment must be retracted gently, with care taken to avoid a fracture and maintain vascularity. To this end, debridement of the endosteum of the osteotomized fragment, including any cement removal, should be avoided until the end of the procedure, when the osteotomy is ready to be closed. Our preferred method for closure is to place 1 prophylactic cable 1 cm distal to the osteotomy, 1 to 2 cables along the diaphyseal segment of the osteotomy, and 1 Luque wire above the less trochanter. A Luque wire is our specific choice for the location above the lesser trochanter because it sits in the effective joint space; however, the use of Luque wires distal to the lesser trochanter is also acceptable. A strut allograft or locking plate can be utilized to reinforce the osteotomy in rare cases or to bridge interprosthetic stress risers. Trochanteric implants are typically avoided because of the low rate of clinically relevant trochanteric migration with this closure technique and because of the high rate of symptomatic implants with trochanteric claws or plates. Alternatives: An alternative osteotomy of similar exposure is the transfemoral osteotomy. Additionally, a variety of non-extended trochanteric osteotomies, such as trochanteric slide osteotomies, offer more limited exposure. Rationale: Femoral surgical exposure for revision THA can be aided by performing transfemoral osteotomies, but these provide less precise control of the separate proximal femoral osteotomized segment(s), and healing and fixation can be less reliable. Less invasive osteotomies such as non-extended trochanteric osteotomies typically do not provide adequate exposure in challenging cases for which ETO is being considered. Expected Outcomes: ETOs have high union rates, and notable trochanteric migration is infrequent. The most common complications are fracture of the osteotomy fragment intraoperatively or postoperatively. Radiographic and clinical union is achieved in 98% of patients. The mean proximal trochanteric osteotomy fragment migration prior to union is 3 mm. ETO fragment migration of >1 cm occurs in just 7% of hips. Postoperative greater trochanter fractures occur in 9% of hips. The 10-year survivorship free of revision for aseptic femoral loosening, free of femoral or acetabular component removal or revision for any reason, and free of reoperation for any reason is 97%, 91%, and 82%, respectively 3 . Important Tips: Attention should be paid to patient anatomy, deformity, surgical approach, and implant type when choosing to perform a laterally based Paprosky or anteriorly based Wagner ETO. Appropriate length of the posterior longitudinal limb of the ETO is approximately 12 to 16 cm distally from the tip of the greater trochanter. Attention must be paid to maintaining vascularity to the osteotomy fragment, including minimizing stripping of the vastus lateralis from the osteotomy fragment and maintaining abductor attachments to the osteotomy fragment. A high-speed pencil-tip burr should be utilized to complete the corners of the osteotomy in a rounded configuration in order to avoid stress risers. The anterior longitudinal limb is completed by controlled fracture of the remaining intervening segment in order to maintain vastus lateralis attachments and vascular supply to the osteotomy fragment. The ETO is closed with use of cerclage cables and/or double-stranded Luque wires, typically utilizing a total of 3 to 4 in order to obtain secure fixation without compromising local biology. Acronyms and Abbreviations: MFT = modular fluted tapered
Creation of a Total Hip Arthroplasty Patient-Specific Dislocation Risk Calculator

Journal of Bone and Joint Surgery | June 15, 2022 | Volume: 104 | Issue: 12 | Pages: 1068-1080

10.2106/jbjs.21.01171 | PMID 36149242

Background: Many risk factors have been described for dislocation following total hip arthroplasty (THA), yet a patient-specific risk assessment tool remains elusive. The purpose of this study was to develop a high-dimensional, patient-specific risk-stratification nomogram that allows dynamic risk modification based on operative decisions. Methods: In this study, 29,349 THAs, including 21,978 primary and 7371 revision cases, performed between 1998 and 2018 were evaluated. During a mean 6-year follow-up, 1521 THAs were followed by a dislocation. Patients were characterized, through individual-chart review, according to non-modifiable factors (demographics, indication for THA, spine disease, prior spine surgery, and neurologic disease) and modifiable operative decisions (operative approach, femoral head diameter, and type of acetabular liner [standard, elevated, constrained, or dual-mobility]). Multivariable regression models and nomograms were developed with dislocation as a binary outcome at 1 year and 5 years postoperatively. Results: Dislocation risk, based on patient-specific comorbidities and operative decisions, was wide-ranging—from 0.3% to 13% at 1 year and from 0.4% to 19% at 5 years after primary THA, and from 2% to 32% at 1 year and from 3% to 42% at 5 years after revision THA. In the primary-THA group, the direct anterior approach (hazard ratio [HR] = 0.27) and lateral approach (HR = 0.58) decreased the dislocation risk compared with the posterior approach. After adjusting for the approach in that group, the combination of a ≥36-mm-diameter femoral head and an elevated liner yielded the largest decrease in dislocation risk (HR = 0.28), followed by dual-mobility constructs (HR = 0.48). In the patients who underwent revision THA, the adjusted risk of dislocation was most markedly decreased by the use of a dual-mobility construct (HR = 0.40), followed by a ≥36-mm femoral head and an elevated liner (HR = 0.88). The adjusted risk of dislocation after revision THA was decreased by acetabular revision (HR = 0.58), irrespective of whether other components were revised. Conclusions: Our patient-specific dislocation risk calculator, which was strengthened by our use of a robust multivariable model that accounted for comorbidities associated with instability, demonstrated wide-ranging patient-specific risks based on comorbidity profiles. The resultant nomograms can be used as a screening tool to identify patients at high risk for dislocation following THA and to individualize operative decisions for evidence-based risk mitigation. Level of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Liner malseating is rare with two modular dual-mobility designs

The Bone & Joint Journal | May 1, 2022 | Volume: 104-B | Issue: 5 | Pages: 598-603

10.1302/0301-620x.104b5.bjj-2021-1734.r1 | PMID 35491581

Aims The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. Methods We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m2 (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2). Results Three liners (1.2%) were malseated, including two MDMs (1.4%) and one G7 (0.9%). No clinical consequence was identified from malseating. The five-year survival free of dislocation was 97.1%, including two DM and one intraprosthetic dislocation. The five-year survival free of revision was 95.4%, with seven revisions. The mean Harris Hip Scores increased from 46 (24 to 69) preoperatively to 81 (40 to 100) at two years postoperatively (p < 0.001). Conclusion The incidence of DM liner malseating after primary THA was low, with no known clinical consequences at mid-term follow-up. Malseating is not exclusive of design, and these findings emphasize the importance of careful evaluation of the liner after impaction to avoid this complication. Cite this article: Bone Joint J 2022;104-B(5):598–603.
Risk factors for long-term hip osteoarthritis in patients with hip dysplasia without surgical intervention

Journal of Hip Preservation Surgery | January 19, 2022 | Volume: 9 | Issue: 1 | Pages: 18-21

10.1093/jhps/hnac007 | PMID 35651707

ABSTRACT Hip dysplasia is a common cause of hip pain and a known risk factor for hip osteoarthritis (OA) and early total hip arthroplasty (THA). Unfortunately, little is known about the specific factors associated with an increased risk of OA. The purpose was (i) to report the overall rate of symptomatic hip OA and THA and (ii) to identify radiographic features and patient characteristics associated with the development of symptomatic hip OA. A geographic database was used to identify all patients aged 14–50 years old diagnosed with symptomatic hip dysplasia between 2000 and 2016. Kaplan–Meier analysis was used to determine the rate of symptomatic hip OA, defined as a Tönnis grade of ≥1 on hip radiograph. Univariate and multivariate proportional hazard regression models were performed to determine risk factors for OA. One hundred and fifty-nine hips (144 patients) with hip dysplasia (52 F:107 M) out of 1893 patients with hip pain were included. Of these, 45 (28%) had severe hip dysplasia with a lateral center-edge angle ≤18°. Mean age at time of presentation was 26.1 (±10.1) years. Mean follow-up time was 8.2 (±5) years. The rate of OA was 20%. THA was performed in 11% of patients. Body mass index &gt;29 (P = 0.03) and increased age (P &lt; 0.01) were risk factors for OA. Patients with symptomatic hip dysplasia are at significant risk of developing hip OA. Body mass index &gt;29 and age ≥35 years at the time of presentation with hip pain were risk factors for hip OA.