Background and Purpose— Even though endovascular coils have been widely used for the treatment of intracranial aneurysms, the cellular and molecular responses of aneurysms to the coils after embolization remain poorly understood. The aim of the present study was to understand the mechanism of apoptosis in aneurysms embolized with platinum coils in the rabbit model of elastase-induced aneurysms. Methods— Elastase-induced saccular aneurysms were created at the origin of the right common carotid artery in 30 rabbits. Aneurysms were allowed to mature for 8 weeks, after which 20 aneurysms were embolized with platinum coils by endovascular means. After 2 (n=10) and 4 (n=10) weeks of implantation, aneurysm samples harboring coils were harvested for apoptotic studies. The remaining 10 uncoiled aneurysms were used as controls; additional controls included the left common carotid artery, which had not undergone any surgical procedure. Control samples were harvested at 12 weeks after aneurysm creation. Results— Expression of procaspases-3, -8, and -9 was elevated in coiled aneurysms embolized with platinum coils at both time points when compared with uncoiled aneurysms and the left common carotid artery. Cleaved caspases-3, -8, and -9 were found to be expressed only at 4 weeks after embolization. Cells within the aneurysm cavity were terminal dUTP nick end-labeling–positive at 4 weeks only. These apoptotic cells were identified as smooth muscle actin–positive cells. Expression of tumor necrosis-α was high in coiled aneurysms when compared with controls. There was no significant difference in the expression of Fas ligand among groups. Decreased expression of antiapoptotic proteins Bcl-2 and phospho-Bad, as well as increased expression of proapoptotic proteins Bax and Bid, was observed in coiled aneurysms at both time points. Conclusions— Activation of apoptosis in aneurysms after embolization with platinum coils is induced by both tumor necrosis factor-α–mediated extrinsic and Bcl-2-mediated intrinsic pathways.
A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms
Background and Purpose— We report a preclinical study of a new endoluminal device for aneurysm occlusion to test the hypothesis that the device, even without use of intrasaccular coil placement, could occlude saccular aneurysms without causing substantial parent artery compromise or compromise of adjacent, small branch arteries. Methods— The Pipeline Neuroendovascular Device (Pipeline NED; Chestnut Medical Technologies, Inc) is a braided, tubular, bimetallic endoluminal implant aimed at occlusion of saccular aneurysms through flow disruption along the aneurysm neck. The device was implanted across the necks of 17 elastase-induced aneurysms in the New Zealand white rabbit model and followed for 1 month (n=6), 3 months (n=5), and 6 months (n=6). In each subject, a second device was implanted in the abdominal aorta to cover the origins of lumbar arteries. Aneurysm occlusion rates by angiography (grade 1, complete occlusion; grade 2, near-complete occlusion; and grade 3, incomplete occlusion) were documented. Percent area stenosis of the parent arteries was calculated. Presence of distal emboli in the downstream vessels in the parent artery and branch artery stenosis or occlusion was noted. Results— Grades 1, 2, and 3 occlusion rates were noted in 9 (53%), 6 (35%), and 2 (12%) of 17 aneurysms, respectively, indicating an 88% rate of complete or near complete occlusion. No cases of branch artery occlusion or distal emboli in the downstream vessels of the parent artery, specifically the subclavian artery, were seen. Parent artery compromise from neointimal hyperplasia was minimal in most cases. Conclusions— The Pipeline NED is a trackable, bio- and hemocompatible device able to occlude saccular aneurysms with preservation of the parent artery and small, adjacent branch vessels.
Specificity of MR Angiography as a Confirmatory Test for Carotid Artery Stenosis: Is It Valid?
American Journal of Roentgenology | March 21, 2007 | Volume: 188 | Issue: 4 | Pages: 1114-1116
Background and Purpose— The purpose of this study was to determine whether implanting exogenous fibroblasts on platinum coils could enhance intra-aneurysmal fibrosis. Hypotheses included: (1) fibroblast-coated (FBC) platinum coils can improve angiographic results after embolization; and (2) FBC platinum coils can accelerate histological healing of embolized aneurysms. Methods— Experimental aneurysms in rabbits were embolized with control platinum coils (n=18) or FBC coils (n=18). Subjects were euthanized at 14 days, 1 month, 3 months and 6 months after implantation. Digital subtraction angiography was used to evaluate stability after embolization. Histological samples were examined with a grading system (range, 0 to 12) based on neck and dome healing. Results— Histology total scores and fibrosis ratio at 14 days were significantly greater in the FBC coil group compared with controls (6.6±1.9 versus 2.5±1.1, 1.2±0.6% versus 0.2±0.3%, respectively; P =0.0090). Cavities embolized with FBC coils showed cellular proliferation and thrombus organization, with an endothelialized membrane bridging the neck. There were no differences between groups in the later timepoints. The FBC coil group showed radiographic stability in 11 (61%) cases, coil compaction in 2 (11%) cases, and progressive occlusion in 5 (28%) cases. No progressive occlusion was seen in controls; 3 (17%) of 18 control cases exhibited coil compaction ( P =0.0546). Conclusions— FBC coils can accelerate early histological healing compared with control coils in the rabbit aneurysm model.
Vertebral Endplate Fractures: An Indicator of the Abnormal Forces Generated in the Spine After Vertebroplasty
Journal of Bone and Mineral Research | September 29, 2006 | Volume: 21 | Issue: 11 | Pages: 1797-1802
Abstract Vertebroplasty alters spinal biomechanics and may lead to incident vertebral fractures. The endplate localization of prevalent and incident fractures was evaluated in 86 patients. In the absence of vertebroplasty, superior endplate fractures predominate. After the procedure, inferior endplate fractures are disproportionately common in adjacent vertebrae immediately above the treated level, potentially supporting a causative relationship between vertebroplasty and incident fractures. Introduction: To determine retrospectively whether new-onset fractures after vertebroplasty tend to cluster in the endplate immediately adjacent to the cemented vertebra. Materials and Methods: Institutional Review Board approval and patient consent for use the use of medical records were obtained for this study. We performed a retrospective review of patients with new (incident) vertebral fractures after vertebroplasty. The median age for these patients was 72.5 years, and 58 (67.4%) were women. Fractures were diagnosed on the basis of MRI or bone scan and were catalogued based on their location within the vertebral body (superior endplate, inferior endplate, or holo-vertebral). χ2 and generalized estimating equation (GEE) analyses were used to compare the distribution of fracture subtypes among pre-existing (prevalent) and incident fractures. Results: The patients had 313 prevalent osteoporotic vertebral fractures and were treated at 137 vertebral levels. Among prevalent fractures, superior endplate fractures predominated (57% superior, 11% inferior; p < 0.0001). After vertebroplasty, 186 incident fractures developed in these 86 patients. Seventy-seven (41%) of these incident fractures occurred adjacent to treated vertebrae. Nonadjacent, incident fractures, like prevalent fractures, occurred predominantly along superior endplate. Incident fractures immediately above treated levels, however, localized disproportionately to the inferior endplate (30% superior, 57% inferior; p < 0.0001). Conclusions: There are an increased number of inferior endplate fractures of the vertebral body immediately cephalad to the treated level.
Dimpled Appearance of a Posterior Communicating Artery Saccule: An Angiographic Indicator of Arterial Infundibula
American Journal of Roentgenology | November 15, 2005 | Volume: 185 | Issue: 5 | Pages: 1358-1360