AbstractModeling the flow dynamics in cerebral aneurysms after the implantation of intrasaccular devices is important for understanding the relationship between flow conditions created immediately posttreatment and the subsequent outcomes. This information, ideally available a priori based on computational modeling prior to implantation, is valuable to identify which aneurysms will occlude immediately and which aneurysms will likely remain patent and would benefit from a different procedure or device.In this report, a methodology for modeling the hemodynamics in intracranial aneurysms treated with intrasaccular flow diverting devices is described. This approach combines an image‐guided, virtual device deployment within patient‐specific vascular models with an immersed boundary method on adaptive unstructured grids. A partial mesh refinement strategy that reduces the number of mesh elements near the aneurysm dome where the flow conditions are largely stagnant was compared with the full refinement strategy that refines the mesh everywhere around the device wires.The results indicate that using the partial mesh refinement approach is adequate for analyzing the posttreatment hemodynamics, at a reduced computational cost. The results obtained on a series of four cerebral aneurysms treated with different intrasaccular devices were in good qualitative agreement with angiographic observations.Promising results were obtained relating posttreatment flow conditions and outcomes of treatments with intrasaccular devices, which need to be confirmed on larger series.
Impact of Balloon Guide Catheter Use on Clinical and Angiographic Outcomes in the STRATIS Stroke Thrombectomy Registry
Background and Purpose— Mechanical thrombectomy has been shown to improve clinical outcomes in patients with acute ischemic stroke. However, the impact of balloon guide catheter (BGC) use is not well established. Methods— STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter study of patients with large vessel occlusion treated with the Solitaire stent retriever as first-line therapy. In this study, an independent core laboratory, blinded to the clinical outcomes, reviewed all procedures and angiographic data to classify procedural technique, target clot location, recanalization after each pass, and determine the number of stent retriever passes. The primary clinical end point was functional independence (modified Rankin Scale, 0–2) at 3 months as determined on-site, and the angiographic end point was first-pass effect (FPE) success rate from a single device attempt (modified Thrombolysis in Cerebral Infarction, ≥2c) as determined by a core laboratory. Achieving modified FPE (modified Thrombolysis in Cerebral Infarction, ≥2b) was also assessed. Comparisons of clinical outcomes were made between groups and adjusted for baseline and procedural characteristics. All participating centers received institutional review board approval from their respective institutions. Results— Adjunctive technique groups included BGC (n=445), distal access catheter (n=238), and conventional guide catheter (n=62). The BGC group had a higher rate of FPE following first pass (212/443 [48%]) versus conventional guide catheter (16/62 [26%]; P =0.001) and distal access catheter (83/235 [35%]; P =0.002). Similarly, the BGC group had a higher rate of modified FPE (294/443 [66%]) versus conventional guide catheter (26/62 [42%]; P <0.001) and distal access catheter (129/234 [55%]; P =0.003). The BGC group achieved the highest rate of functional independence (253/415 [61%]) versus conventional guide catheter (23/55 [42%]; P =0.007) and distal access catheter (113/218 [52%]; P =0.027). Final revascularization and mortality rates did not differ across the groups. Conclusions— BGC use was an independent predictor of FPE, modified FPE, and functional independence, suggesting that its routine use may improve the rates of early revascularization success and good clinical outcomes. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT02239640.
In vivo comparison of shape memory polymer foam‐coated and bare metal coils for aneurysm occlusion in the rabbit elastase model
Journal of Biomedical Materials Research Part B: Applied Biomaterials | February 18, 2019 | Volume: 107 | Issue: 8 | Pages: 2466-2475
Abstract BACKGROUND Flow diversion (FD) is effective for treatment of intracranial internal carotid artery (ICA) aneurysms. OBJECTIVE To determine whether carotid siphon (CS) geometry influences the efficacy of FD when employed for ICA aneurysms. METHODS Outcomes of a consecutive series of patients with ICA aneurysms treated with FD were retrospectively reviewed. CS anatomy was quantified through measurement of the posterior, anterior, and anterosuperior bend angles in accordance with previously described methodology. The relationship of CS geometry to likelihood of incomplete aneurysm occlusion at 1 yr after treatment was assessed with multivariate logistic regression analysis. RESULTS There were 167 ICA aneurysms in 164 patients treated with FD during the study period. The mean age of our cohort was 55.7 yr (standard deviation [SD]: 12.3) and a majority of patients were female (145/164, 86.8%). Anterior (47.4 degrees vs 8.5, P < .001) and anterosuperior bend angles (100.9 vs 76.5, P = .002) were significantly greater in aneurysms that required repeat FD after initial treatment. On multivariate logistic regression analysis, increasing patient age (unit odds ratio [OR]: 1.05, 95% confidence interval [CI] 1.01-1.08; P = .003) and anterior bend angle ≥–3.5 (OR: 2.47, 95% CI 1.04-5.86; P = .046) were associated with increased odds of incomplete aneurysm occlusion at 1 yr after treatment. CONCLUSION These findings suggest that variations in CS anatomy may influence the efficacy of FD treatment and should be analyzed prior to offering FD for treatment of ICA aneurysms. Further investigation into the hemodynamic effects of CS geometry is warranted.
Acute ischemic stroke secondary to cardiac embolus of a ‘foreign body’ material after a redo sternotomy for mitral valve replacement: A case report
Summary Cardiac surgery has been shown to be associated with increased risk of acute ischemic stroke. This report presents a case of a successful mechanical embolectomy procedure to treat a patient for an acute ischemic stroke, which was caused by the cardiac embolization of a ‘foreign body’ containing debris following a redo sternotomy procedure for mitral valve replacement and tricuspid valve annuloplasty.
Percutaneous vertebroplasty for osteoporotic vertebral compression fracture
Cochrane Database of Systematic Reviews | November 6, 2018 | Volume: 2018 | Issue: 11 | Pages: No page available
Background: Flow diverters (FD) are increasingly used in the treatment of intracranial aneurysms. The risk of distal thromboembolic complications with FD is high, even in patients treated with dual antiplatelet therapy. The aim of the study was to understand the downstream vascular wall changes, by measuring the pulse wave velocity and vascular contractility following flow diverter treatment in a rabbit model. Methods: FD (Pipeline Embolic Device, Medtronic) were implanted in normal rabbits and sham-operated aorta were used as controls (n=5 for each group). Pulse wave imaging with ultra-fast ultrasound at 1600 frames per second (Vantage, Verasonics, Inc.) was performed in the vessel wall distal to FD, prior to device implantation and at 8 weeks follow up to measure the pulse wave propagation. Force contraction studies were conducted in the aortic rings using organ bath to assess the vascular functions. Results: The difference in pulse wave velocity (PWV) in the follow-up compared to pre-implantation was significantly higher (p=0.03,Fig 1A) in the distal vessels compared to sham controls (mean difference of PWV was 1.18 m/s and -0.37m/s, respectively as shown in Fig 1B). Conversely, the distal aortic segments to FD exhibited 55% increase in the level of vascular contractility compared to that of proximal segments (p=0.002). There is a significant positive correlation between mean PWV and mean vascular contractility. Conclusion: Our study found changes in the PWV after implantation of the FD, which correlated with vascular contractility. These results could explain vascular wall changes downstream following FD implantation.
Abstract TP54: Machine-Learned Characterization of Acute Ischemic Stroke Clots Reveals a Correlation Between Clot Composition and Density on CT
Stroke | October 8, 2018 | Volume: 49 | Issue: Suppl_1 | Pages: No page available
Introduction: The composition of acute ischemic stroke (AIS) blood clots can impact their successful removal via endovascular therapy. Identification of the clot composition prior to endovascular treatment may influence the optimal treatment strategy. In this study, we aimed to investigate the relationship between the Hounsfield Unit intensity on CT and machine-learned characterization of clot composition. Methods: Prior to endovascular treatment, each patient had a non-contrast CT performed. Histopathological analysis of the clots was performed and clot composition was quantified via standard thresholding techniques using Adobe Photoshop. In addition, following representative cell labeling by an expert pathologist, image segmentation algorithms (Orbital Image Analysis, Actelion Ltd.) were trained on each case to quantify composition by cell type. The clots were categorized into 3 groups: red blood cell (RBC) dominant (>50%), RBC proportion equal to fibrin and fibrin dominant (>50%). Correlations between clot composition and Hounsfield Units (HU) density on CT were assessed. A positive Hyperdense Artery Sign was defined as ≥50 HU. Results: Twenty patients were included in the study. There was a significant correlation between clots quantified using Adobe Photoshop Image-Pro and Orbit image analysis ( ρ = 0.837, p < 0.001). A significant relationship was found between clot composition and the presence of a HAS sign, ( X 2 (2) = 6.496, p = 0.039). There is a significant positive correlation between percentage of RBC in the clot and the presence of a HAS sign ( ρ = 0.632, p = 0.002**). There is also a significant positive correlation between the presence of fibrin-rich and the absence of a HAS sign ( ρ = 0.600, p = 0.004**). Conclusion: Machine learning software can accurately quantify AIS clot composition. The Hounsfield unit density of an AIS clot on a non-contrast CT correlates with the composition of the clot. Measuring the HU of the clot on CT prior to endovascular intervention may inform the clinician of the clot type and help to determine the most appropriate treatment strategy for that clot.
Novel aspiration catheter design for acute stroke thrombectomy
Journal of NeuroInterventional Surgery | July 30, 2018 | Volume: 11 | Issue: 2 | Pages: 190-195
Background Navigable, large diameter aspiration catheters demonstrate markedly improved recanalization rates over smaller lumen devices in suction embolectomy. We evaluated the performance of a novel aspiration catheter system designed to maximize lumen size, and compare it to other commercially available aspiration catheters. Methods The 6F R4Q aspiration catheter system comprises a proximal pusher wire of 117 cm length connected to a distal catheter of 25 cm length. When placed through standard guide catheters and into the cerebral circulation, the proximal catheter makes a tight seal between its outer surface and the guide catheter’s inner surface. During aspiration, in vitro flow rates and tip suction force under gentle retraction were compared among 10 commercially available aspiration catheters and the R4Q system. Results The R4Q 6F, 5F, 4F, and 3F catheters achieved flow rates at least 21.9%, 24.7%, 61.9%, and 244.7% greater than the other catheters tested respectively and the R4Q 6F produced a 140.2% higher tip force than a catheter of similar size. Fluid flow rate in the R4Q 6F increased on retraction into the guide catheter, delivering a 58.2% increase from fully extended to fully retracted. Conclusion The R4Q design demonstrates a substantial increase in aspirated flow rate and suction force due to an increased effective diameter than standard tubular catheter designs tested. The prominent increase in the aspiration parameters measured in vitro supports the potential for improved clinical results during stroke thrombectomy procedures.