Citations 13

Real-Time Monitoring of Electrode Surface Changes in Fast-Scan Cyclic Voltammetry Using Fourier Transform Electrochemical Impedance Spectroscopy

ACS Omega | January 9, 2025 | Volume: 10 | Issue: 2 | Pages: 2061-2068

10.1021/acsomega.4c08240 | PMID 39866634

Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection

The Analyst | April 4, 2024 | Volume: 149 | Issue: 10 | Pages: 3008-3016

10.1039/d3an02205f | PMID 38606455

The distinct impacts of fouling mechanisms on a carbon fiber microelectrode and an Ag/AgCl reference electrode, affecting their performance in neurotransmitter detection via Fast-scan Cyclic Voltammetry.
Techniques for Measurement of Serotonin: Implications in Neuropsychiatric Disorders and Advances in Absolute Value Recording Methods

ACS Chemical Neuroscience | November 29, 2023 | Volume: 14 | Issue: 24 | Pages: 4264-4273

10.1021/acschemneuro.3c00618 | PMID 38019166

Neurochemical Concentration Prediction Using Deep Learning vs Principal Component Regression in Fast Scan Cyclic Voltammetry: A Comparison Study

ACS Chemical Neuroscience | July 25, 2022 | Volume: 13 | Issue: 15 | Pages: 2288-2297

10.1021/acschemneuro.2c00069 | PMID 35876751

Tonic Serotonin Measurements In Vivo Using N-Shaped Multiple Cyclic Square Wave Voltammetry

Analytical Chemistry | December 2, 2021 | Volume: 93 | Issue: 51 | Pages: 16987-16994

10.1021/acs.analchem.1c02131 | PMID 34855368

Enhanced Dopamine Sensitivity Using Steered Fast-Scan Cyclic Voltammetry

ACS Omega | December 1, 2021 | Volume: 6 | Issue: 49 | Pages: 33599-33606

10.1021/acsomega.1c04475 | PMID 34926907

Feasibility of Applying Fourier Transform Electrochemical Impedance Spectroscopy in Fast Cyclic Square Wave Voltammetry for theIn VivoMeasurement of Neurotransmitters

Analytical Chemistry | November 29, 2021 | Volume: 93 | Issue: 48 | Pages: 15861-15869

10.1021/acs.analchem.1c02308 | PMID 34839667

Automatic and Reliable Quantification of Tonic Dopamine Concentrations In Vivo Using a Novel Probabilistic Inference Method

ACS Omega | March 3, 2021 | Volume: 6 | Issue: 10 | Pages: 6607-6613

10.1021/acsomega.0c05217 | PMID 33748573

Sensitive and Selective Measurement of Serotonin in Vivo Using Fast Cyclic Square-Wave Voltammetry

Analytical Chemistry | December 2, 2019 | Volume: 92 | Issue: 1 | Pages: 774-781

10.1021/acs.analchem.9b03164 | PMID 31789495

Fast Cyclic Square-Wave Voltammetry To Enhance Neurotransmitter Selectivity and Sensitivity

Analytical Chemistry | October 25, 2018 | Volume: 90 | Issue: 22 | Pages: 13348-13355

10.1021/acs.analchem.8b02920 | PMID 30358389

Abstract Although fast-scan cyclic voltammetry (FSCV) has been widely used for in vivo neurochemical detection, the sensitivity and selectivity of the technique can be further improved. In this study, we develop fast cyclic square-wave voltammetry (FCSWV) as a novel voltammetric technique that combines large-amplitude cyclic square-wave voltammetry (CSWV) with background subtraction. A large-amplitude, square-shaped potential was applied to induce cycling through multiple redox reactions within a square pulse to increase sensitivity and selectivity when combined with a two-dimensional voltammogram. As a result, FCSWV was significantly more sensitive than FSCV (n = 5 electrodes, two-way ANOVA, p = 0.0002). In addition, FCSWV could differentiate dopamine from other catecholamines (e.g., epinephrine and norepinephrine) and serotonin better than conventional FSCV. With the confirmation that FCSWV did not influence local neuronal activity, despite the large amplitude of the square waveform, it could monitor electrically induced phasic changes in dopamine release in rat striatum before and after injecting nomifensine, a dopamine reuptake inhibitor.