Citations 9

Real-Time Monitoring of Electrode Surface Changes in Fast-Scan Cyclic Voltammetry Using Fourier Transform Electrochemical Impedance Spectroscopy

ACS Omega | January 9, 2025 | Volume: 10 | Issue: 2 | Pages: 2061-2068

10.1021/acsomega.4c08240 | PMID 39866634

Tonic Serotonin Measurements In Vivo Using N-Shaped Multiple Cyclic Square Wave Voltammetry

Analytical Chemistry | December 2, 2021 | Volume: 93 | Issue: 51 | Pages: 16987-16994

10.1021/acs.analchem.1c02131 | PMID 34855368

Enhanced Dopamine Sensitivity Using Steered Fast-Scan Cyclic Voltammetry

ACS Omega | December 1, 2021 | Volume: 6 | Issue: 49 | Pages: 33599-33606

10.1021/acsomega.1c04475 | PMID 34926907

Feasibility of Applying Fourier Transform Electrochemical Impedance Spectroscopy in Fast Cyclic Square Wave Voltammetry for theIn VivoMeasurement of Neurotransmitters

Analytical Chemistry | November 29, 2021 | Volume: 93 | Issue: 48 | Pages: 15861-15869

10.1021/acs.analchem.1c02308 | PMID 34839667

Sensitive and Selective Measurement of Serotonin in Vivo Using Fast Cyclic Square-Wave Voltammetry

Analytical Chemistry | December 2, 2019 | Volume: 92 | Issue: 1 | Pages: 774-781

10.1021/acs.analchem.9b03164 | PMID 31789495

Fast Cyclic Square-Wave Voltammetry To Enhance Neurotransmitter Selectivity and Sensitivity

Analytical Chemistry | October 25, 2018 | Volume: 90 | Issue: 22 | Pages: 13348-13355

10.1021/acs.analchem.8b02920 | PMID 30358389

Abstract Although fast-scan cyclic voltammetry (FSCV) has been widely used for in vivo neurochemical detection, the sensitivity and selectivity of the technique can be further improved. In this study, we develop fast cyclic square-wave voltammetry (FCSWV) as a novel voltammetric technique that combines large-amplitude cyclic square-wave voltammetry (CSWV) with background subtraction. A large-amplitude, square-shaped potential was applied to induce cycling through multiple redox reactions within a square pulse to increase sensitivity and selectivity when combined with a two-dimensional voltammogram. As a result, FCSWV was significantly more sensitive than FSCV (n = 5 electrodes, two-way ANOVA, p = 0.0002). In addition, FCSWV could differentiate dopamine from other catecholamines (e.g., epinephrine and norepinephrine) and serotonin better than conventional FSCV. With the confirmation that FCSWV did not influence local neuronal activity, despite the large amplitude of the square waveform, it could monitor electrically induced phasic changes in dopamine release in rat striatum before and after injecting nomifensine, a dopamine reuptake inhibitor.
Multi-waveform fast-scan cyclic voltammetry mapping of adsorption/desorption kinetics of biogenic amines and their metabolites

Analytical Methods | May 22, 2018 | Volume: 10 | Issue: 24 | Pages: 2834-2843

10.1039/c8ay00352a | PMID 31131044

A novel multi-waveform FSCV (M-FSCV) developed for characterizing adsorption/desorption kinetics of neurotransmitters.
A baseline drift detrending technique for fast scan cyclic voltammetry

The Analyst | September 27, 2017 | Volume: 142 | Issue: 22 | Pages: 4317-4321

10.1039/c7an01465a | PMID 29063091

A simple, and yet robust, high pass filter is designed to remove non-linear background drift in fast scan cyclic voltammetry.
Monitoring In Vivo Changes in Tonic Extracellular Dopamine Level by Charge-Balancing Multiple Waveform Fast-Scan Cyclic Voltammetry

Analytical Chemistry | October 24, 2016 | Volume: 88 | Issue: 22 | Pages: 10962-10970

10.1021/acs.analchem.6b02605 | PMID 27774784