Abstract 12776: Long Term Mortality With Right Ventricular Apical Versus Septal Pacing

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12776

Introduction: Right ventricular apical (RVA) pacing appears to have detrimental effects on cardiac function and long term outcomes. Right ventricular non-apical (RVNA) pacing, especially in the septal position, has been postulated as an alternative that may lead to less morbidity and mortality. Prior studies have shown conflicting results and been limited by small numbers and short follow-up. We aimed to determine if right ventricular septal lead position was associated with a reduction in long-term mortality compared to RVA lead position. Methods: Patients who underwent dual-chamber pacemaker implantation from 2004 through 2013 were evaluated for right ventricular lead position based on chest radiographs. Lead positions were divided in to apical or non-apical. Non-apical lead positions were subdivided to isolate a septal lead position group. Mortality was compared between these groups. Results: During the study period, 3456 patients underwent dual-chamber pacemaker placement and had images appropriate for lead position evaluation. The group was 53.5% male with a mean age of 74 ± 13 years. RVNA lead position was found in 976 (28.2%) patients, including 243 (7.0%) with a septal position. There was no significant difference in age or prior heart failure diagnosis between groups. Kaplan-Meier survival analysis did not reveal a significant difference in mortality between patients with RVA versus RVNA lead position during 5 year follow-up (p = 0.82). However, septal lead position was associated with a significantly lower mortality compared with RVA position (p = 0.03) (figure). Conclusions: Right ventricular septal lead position is associated with a lower long-term mortality than RVA lead position. This has substantial implications regarding the preferred site for ventricular pacing lead placement.
A sound method for axillary vein access

Journal of Cardiovascular Electrophysiology | December 18, 2020 | Volume: 32 | Issue: 2 | Pages: 466-467

10.1111/jce.14839 | PMID 33337565

A Sound Method for Axillary Vein Access

No container title available | December 5, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.160722565.59453010/v1

Ultrasound guided venous access Is important to minimize pneumothorax and unnecessary incisions in patients undergoing device implant.
A cool modality to restore sinus rhythm

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0551

Abstract Background Slowing electrical conduction by cooling the myocardium can be used for defibrillation. We previously demonstrated the efficacy of a small cold device placed in oblique sinus (OS) in terminating atrial fibrillation (AF). However, the parameters needed to achieve effective atrial defibrillation are unknown. Purpose Assess effect of the size of cooled myocardium on frequency of AF termination in acute canine animal models. Methods Sternotomy was performed under general anesthesia in 10 acute canine experiments. AF was induced using rapid atrial pacing and intra-myocardial epinephrine and acetylcholine injections. Once AF sustained for at least 30s, either a cool (7–9°C) or placebo (body temperature) device was placed in the OS. Four device sizes were tested; ½X½, ¾X¾, and 1X1 inch devices and two ¾X¾ inch devices placed side by side simultaneously. Time to AF termination was recorded. Chi-squared or Fisher's exact test were used to compare the frequency of arrhythmia termination with cooling versus placebo. Results A total of 166 applications were performed (89 cool vs 77 placebo) in 10 animal experiments. Overall, AF terminated in 82% of the cooling applications vs. 67.5% of placebo (P=0.03, Figure 1). For the ½X½ inch device 88% of cold applications restored sinus rhythm vs. 63.6% for placebo (P=0.05). The frequency of sinus restoration for cold ¾X¾, 1X1 and two ¾X¾ side by side devices was 86.7%, 83.3% and 70% respectively. Time to sinus restoration when achieved was within three minutes was also not significantly changed. Conclusion Placing a cool device in the oblique sinus can terminate AF and efficacy is not affected by the size of device. Funding Acknowledgement Type of funding source: Private grant(s) and/or Sponsorship. Main funding source(s): MediCool Technologies
Activation pattern during his pacing: how close are we to normal physiology?

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0804

Abstract Background His bundle pacing aims to mimic the activation pattern of normal conduction to maintain ventricular synchrony. However, selective His capture can be challenging, and the activation sequence during His pacing may not replicate normal conduction. Purpose Compare the right ventricular (RV) and left ventricular (LV) activation pattern in sinus rhythm and His bundle pacing. Methods Baseline LV and RV map was created in sinus rhythm using Rhythmia mapping system (Boston Scientific Corporation) in canine animal model. Medtronic 3830 lead was placed near the bundle of His under fluoroscopic, intracardiac echocardiogram, and electroanatomic guidance. Conduction system capture was confirmed by observing a QRS duration <120ms and an isoelectric segment between pacing artifact and QRS on surface ECG. Repeat LV and RV activation map was obtained during His pacing. Average QRS, HV and pacing to V intervals were calculated with standard deviation. Results Mapping was performed successfully in four animals. At baseline, the average QRS duration was 44±2.6ms and HV interval was 32±4.2ms. Earliest site of myocardial activation was in the mid-septal LV region. The earliest RV myocardial activation was also at the septum closer to the apex, but later than the LV (Figure1A). With His pacing, the average QRS duration was 70±17.0ms and the average stim to V interval was 31±8.7ms. During His pacing, the earliest site of activation was in the RV septum, with an activation pattern from base to apex in both the RV and LV. Conclusion Unlike normal physiology, the activation pattern during conduction system pacing is from base to apex with earliest site in the RV. Funding Acknowledgement Type of funding source: Public hospital(s). Main funding source(s): Mayo Clinic
Injectable conductive hydrogel restores conduction through ablated myocardium

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 | PMID 32966655

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.
Injectable conductive hydrogel restores conduction through ablated myocardium

No container title available | July 6, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159406900.02369826

Abstract Introduction: Therapies for substrate-related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization. Methods: A nanocellulose-carbon nanotube conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue. Results: The conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The DC conductivity under aqueous conduction was 4.3·10-1 S/cm. In 4 canine hearts, when compared to the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation similar to baseline in all 4 hearts. Gross specimen examination demonstrated retention of the hydrogel within the tissue. Conclusions: This proof-of-concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long-term retention and biocompatibility of the hydrogel through in vivo experimentation.
Stroke Prophylaxis in Patients with Atrial Fibrillation and End-Stage Renal Disease

Journal of Clinical Medicine | January 3, 2020 | Volume: 9 | Issue: 1 | Pages: 123

10.3390/jcm9010123 | PMID 31906546

Atrial fibrillation (AF) is an important comorbidity in patients with end-stage renal disease (ESRD) undergoing dialysis that portends increased health care utilization, morbidity, and mortality in this already high-risk population. Patients with ESRD have a particularly high stroke risk, which is further compounded by AF. However, the role of anticoagulation for stroke prophylaxis in ESRD and AF is debated. The ESRD population presents a unique challenge because of the combination of elevated stroke and bleeding risks. Warfarin has been traditionally used in this population, but it is associated with significant risks of minor and major bleeding, particularly intracranial, thus leading many clinicians to forgo anticoagulation altogether. When anticoagulation is prescribed, rates of adherence and persistence are poor, leaving many patients untreated. The direct oral anticoagulants (DOACs) may offer an alternative to warfarin in ESRD patients, but these agents have not been extensively studied in this population and uncertainties regarding comparative effectiveness (versus warfarin, each other, and no treatment) remain. In this review, we discuss the current evidence on the risk and benefits of anticoagulants in this challenging population and comparisons between warfarin and DOACs, and review future directions including options for non-pharmacologic stroke prevention.
Single-site ventricular pacing via the coronary sinus in patients with tricuspid valve disease

EP Europace | January 24, 2018 | Volume: 20 | Issue: 4 | Pages: 636-642

10.1093/europace/euw422 | PMID 28339945

Right ventricular pacemaker lead position is associated with differences in long‐term outcomes and complications

Journal of Cardiovascular Electrophysiology | May 25, 2017 | Volume: 28 | Issue: 8 | Pages: 924-930

10.1111/jce.13256 | PMID 28543771

AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.