Back to Authors

Humphries, Romney M.

https://orcid.org/0000-0002-6568-156X

A5028268383 | I901861585

Mayo Clinic

Vanderbilt University Medical Center

Citations 23

Considerations from the College of American Pathologists for Implementation of an Assay for SARS-CoV-2 Testing after a Change in Regulatory Status

Journal of Clinical Microbiology | July 14, 2021 | Volume: 59 | Issue: 10 | Pages: No page available

10.1128/jcm.01167-21 | PMID 34260276

The U.S. Food & Drug Administration (FDA) regulates the marketing of manufacturers’ in vitro diagnostic tests (IVDs), including assays for the detection of SARS-CoV-2.
Considerations for Assessment and Deployment of Rapid Antigen Tests for Diagnosis of Coronavirus Disease 2019

Open Forum Infectious Diseases | March 11, 2021 | Volume: 8 | Issue: 6 | Pages: No page available

10.1093/ofid/ofab110 | PMID 34258309

Abstract Diagnostic testing is a critical tool to mitigate the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, but molecular testing capacity remains limited. Rapid diagnostic tests (RDTs) that detect SARS-CoV-2 protein antigens (Ag) offer the potential to substantially expand testing capacity and to allow frequent, large-scale, population screening. Testing is simple, rapid (results generally available within 15 minutes), and applicable for diagnosis at point of care. However, implementation of Ag RDTs requires a detailed understanding of test performance and operational characteristics in each testing scenario and population being evaluated. Successful implementation of Ag RDTs on a large scale should combine testing with technical oversight and with clinical and public health infrastructure, and will require production at levels much higher than presently possible. In this commentary, we provide detailed considerations for Ag RDT assessment and use cases to encourage and enable broader manufacturing and deployment.
College of American Pathologists (CAP) Microbiology Committee Perspective: the Need for Verification Studies

Journal of Clinical Microbiology | March 24, 2020 | Volume: 58 | Issue: 4 | Pages: No page available

10.1128/jcm.02105-19 | PMID 32213579

Evaluation of the NG-Test MCR-1 Lateral Flow Assay and EDTA-Colistin Broth Disk Elution Methods To Detect Plasmid-Mediated Colistin Resistance among Gram-Negative Bacterial Isolates

Journal of Clinical Microbiology | January 24, 2020 | Volume: 58 | Issue: 4 | Pages: No page available

10.1128/jcm.01823-19 | PMID 31996440

Plasmid-mediated colistin resistance (PMCR) is a global public health concern, given its ease of transmissibility. The purpose of this study was to evaluate two methods for the detection of PMCR from bacterial colonies: (i) the NG-Test MCR-1 lateral flow immunoassay (LFA; NG Biotech, Guipry, France) and (ii) the EDTA-colistin broth disk elution (EDTA-CBDE) screening test method. These methods were evaluated using a cohort of contemporary, clinical Gram-negative bacillus isolates from 3 U.S. academic medical centers (126 isolates of the Enterobacterales , 50 Pseudomonas aeruginosa isolates, and 50 Acinetobacter species isolates; 1 isolate was mcr positive) and 12 mcr -positive CDC-FDA Antibiotic Resistance (AR) Isolate Bank isolates for which reference broth microdilution colistin susceptibility results were available.
Evaluation of Calcium-Enhanced Media for Colistin Susceptibility Testing by Gradient Agar Diffusion and Broth Microdilution

Journal of Clinical Microbiology | November 20, 2019 | Volume: 58 | Issue: 2 | Pages: No page available

10.1128/jcm.01522-19 | PMID 31748324

Despite the increasing reliance on polymyxin antibiotics (polymyxin B and colistin) for treatment of multidrug-resistant Gram-negative infections, many clinical laboratories are unable to perform susceptibility testing due to the lack of accurate and reliable methods. Although gradient agar diffusion is commonly performed for other antimicrobials, its use for polymyxins is discouraged due to poor performance characteristics.
Multicenter Evaluation of Colistin Broth Disk Elution and Colistin Agar Test: a Report from the Clinical and Laboratory Standards Institute

Journal of Clinical Microbiology | September 10, 2019 | Volume: 57 | Issue: 11 | Pages: No page available

10.1128/jcm.01269-19 | PMID 31511331

Susceptibility testing of the polymyxins (colistin and polymyxin B) is challenging for clinical laboratories. The Clinical and Laboratory Standards Institute (CLSI) Antimicrobial Susceptibility Testing Subcommittee evaluated two methods to enable accurate testing of these agents. These methods were a colistin broth disk elution (CBDE) and a colistin agar test (CAT), the latter of which was evaluated using two inoculum volumes, 1 μl (CAT-1) and 10 μl (CAT-10).
Candida auris: An Emerging Yeast Pathogen Posing Distinct Challenges for Laboratory Diagnostics, Treatment, and Infection Prevention

Archives of Pathology & Laboratory Medicine | June 6, 2019 | Volume: 144 | Issue: 1 | Pages: 107-114

10.5858/arpa.2018-0508-ra | PMID 31169997

Context.— Candida auris is an emerging yeast species that was first described in 2009. This ascomycetous yeast is notable for resistance to azole antifungal agents, for environmental persistence, and for its ability to contaminate health care environments, resulting in patient colonization and nosocomial infections. Objective.— To review the state of current knowledge addressing challenges in the accurate identification of C auris in the diagnostic microbiology laboratory, including application of phenotypic, proteomic, and genomic methodologies; characteristics that may predispose the human host to acquiring C auris; transmission; clinical presentations; treatment modalities; environmental decontamination; and infection prevention in health care settings. Data Sources.— The PubMed search engine was used to access peer-reviewed literature published from 2009 to 2019. Conclusions.— The rapid emergence of C auris has presented unique challenges for the areas of laboratory diagnostics and infection prevention and in options for antifungal treatment, which are limited. The current lack of established antifungal susceptibility test breakpoints complicates therapeutic decision making. Enhanced awareness of this pathogen is essential to monitor outbreaks and to reduce the risk of spread within health care environments.
Ceftazidime–avibactam Susceptibility Patterns in Carbapenem-Resistant Enterobacteriaceae in the USA: Results from the Consortium on Resistance against Carbapenems in Klebsiella and Other Enterobacteriaceae (CRACKLE-2)

Open Forum Infectious Diseases | March 29, 2018 | Volume: 4 | Issue: suppl_1 | Pages: S133-S134

10.1093/ofid/ofx163.197

Multicenter Evaluation of the Accelerate PhenoTest BC Kit for Rapid Identification and Phenotypic Antimicrobial Susceptibility Testing Using Morphokinetic Cellular Analysis

Journal of Clinical Microbiology | January 8, 2018 | Volume: 56 | Issue: 4 | Pages: No page available

10.1128/jcm.01329-17 | PMID 29305546

ABSTRACT We describe results from a multicenter study evaluating the Accelerate Pheno system, a first of its kind diagnostic system that rapidly identifies common bloodstream pathogens from positive blood cultures within 90 min and determines bacterial phenotypic antimicrobial susceptibility testing (AST) results within ∼7 h. A combination of fresh clinical and seeded blood cultures were tested, and results from the Accelerate Pheno system were compared to Vitek 2 results for identification (ID) and broth microdilution or disk diffusion for AST. The Accelerate Pheno system accurately identified 14 common bacterial pathogens and two Candida spp. with sensitivities ranging from 94.6 to 100%. Of fresh positive blood cultures, 89% received a monomicrobial call with a positive predictive value of 97.3%. Six common Gram-positive cocci were evaluated for ID. Five were tested against eight antibiotics, two resistance phenotypes (methicillin-resistant Staphylococcus aureus and Staphylococcus spp. [MRSA/MRS]), and inducible clindamycin resistance (MLSb). From the 4,142 AST results, the overall essential agreement (EA) and categorical agreement (CA) were 97.6% and 97.9%, respectively. Overall very major error (VME), major error (ME), and minor error (mE) rates were 1.0%, 0.7%, and 1.3%, respectively. Eight species of Gram-negative rods were evaluated against 15 antibiotics. From the 6,331 AST results, overall EA and CA were 95.4% and 94.3%, respectively. Overall VME, ME, and mE rates were 0.5%, 0.9%, and 4.8%, respectively. The Accelerate Pheno system has the unique ability to identify and provide phenotypic MIC and categorical AST results in a few hours directly from positive blood culture bottles and support accurate antimicrobial adjustment.
Direct-from-Blood-Culture Disk Diffusion To Determine Antimicrobial Susceptibility of Gram-Negative Bacteria: Preliminary Report from the Clinical and Laboratory Standards Institute Methods Development and Standardization Working Group

Journal of Clinical Microbiology | January 5, 2018 | Volume: 56 | Issue: 3 | Pages: No page available

10.1128/jcm.01678-17 | PMID 29305540

ABSTRACT The performance of a disk diffusion test using broth from positive blood cultures as inoculum (direct disk diffusion [dDD]) was evaluated for a collection of 20 challenge isolates of Enterobacteriaceae , Acinetobacter baumannii , and Pseudomonas aeruginosa . Isolates seeded into human blood were inoculated into Bactec Plus Aerobic/F, VersaTREK Redox 1, and BacT/Alert FA Plus bottles and incubated in the respective automated blood culture systems. Disk diffusion results were compared to reference disk diffusion results. Categorical agreement (CA) values for dDD, after removal of random errors due to natural MIC variation, were 87.8%, 88.4%, and 92.2% for the BacT/Alert, Bactec, and VersaTREK systems, respectively. No very major errors (VME) were observed, and major error (ME) rates were 3.0%, 2.3%, and 1.7%, respectively. Incubation of the dDD test samples for 6 h compared to incubation for 16 to 18 h resulted in 19.9% of tests having too light of growth to allow reading of zones of inhibition. Among the evaluable dDD tests, CA values were 58.9%, 76.6%, and 73.2% for the isolates seeded into the BacT/Alert, Bactec, and VersaTREK systems, respectively. VME rates for isolates seeded into these systems were 2.2%, 1.8%, and 3.0%, respectively, and ME rates were 25.4%, 6.1%, and 2.8%, respectively, at the 6-h reading. The best performance of dDD was found for blood cultures with bacterial concentrations in the range of 7.6 × 10 7 to 5.0 × 10 8 CFU/ml; CA values ranged from 94.7 to 96.2% for these concentrations after 18 h of incubation and from 76.9 to 84.1% after 6 h of incubation. These preliminary data demonstrate the potential accuracy of dDD testing by the clinical laboratory.