Citations 62

Bad to worse: mitral regurgitation increases from moderate–severe to torrential following cardioversion to sinus rhythm

European Heart Journal - Cardiovascular Imaging | October 7, 2023 | Volume: 25 | Issue: 1 | Pages: e63-e63

10.1093/ehjci/jead253 | PMID 37804530

Role of lipoprotein(a) concentrations in bioprosthetic aortic valve degeneration

Heart | August 29, 2023 | Volume: 110 | Issue: 4 | Pages: 299-305

10.1136/heartjnl-2023-322987 | PMID 37643771

Objectives Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. Methods In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. Results In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). Conclusions High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.
The impact of moderate aortic stenosis in acute myocardial infarction: A multicenter retrospective study

Catheterization and Cardiovascular Interventions | May 5, 2023 | Volume: 102 | Issue: 1 | Pages: 159-165

10.1002/ccd.30676 | PMID 37146200

AbstractBackgroundAortic stenosis (AS) is associated with myocardial ischemia through different mechanisms and may impair coronary arterial flow. However, data on the impact of moderate AS in patients with acute myocardial infarction (MI) is limited.AimsThis study aimed to investigate the impact of moderate AS in patients presenting with acute myocardial infarction (MI).MethodsWe conducted a retrospective analysis of all patients who presented with acute MI to all Mayo Clinic hospitals, using the Enterprise Mayo PCI Database from 2005 to 2016. Patients were stratified into two groups: moderate AS and mild/no AS. The primary outcome was all cause mortality.ResultsThe moderate AS group included 183 (13.3%) patients, and the mild/no AS group included 1190 (86.7%) patients. During hospitalization, there was no difference between both groups in mortality. Patients with moderate AS had higher in‐hospital congestive heart failure (CHF) (8.2% vs. 4.4%, p = 0.025) compared with mild/no AS patients. At 1‐year follow‐up, patients with moderate AS had higher mortality (23.9% vs. 8.1%, p < 0.001) and higher CHF hospitalization (8.3% vs. 3.7%, p = 0.028). In multivariate analysis, moderate AS was associated with higher mortality at 1‐year (odds ratio 2.4, 95% confidence interval [1.4–4.1], p = 0.002). In subgroup analyses, moderate AS increased all‐cause mortality in STEMI and NSTEMI patients.ConclusionThe presence of moderate AS in acute MI patients was associated with worse clinical outcomes during hospitalization and at 1‐year follow‐up. These unfavorable outcomes highlight the need for a close follow‐up of these patients and for timely therapeutic strategies to best manage these coexisting conditions.
Developing an Echocardiography-Based, Automatic Deep Learning Framework for the Differentiation of Increased Left Ventricular Wall Thickness Etiologies

Journal of Imaging | February 20, 2023 | Volume: 9 | Issue: 2 | Pages: 48

10.3390/jimaging9020048 | PMID 36826967

Aims:Increased left ventricular (LV) wall thickness is frequently encountered in transthoracic echocardiography (TTE). While accurate and early diagnosis is clinically important, given the differences in available therapeutic options and prognosis, an extensive workup is often required to establish the diagnosis. We propose the first echo-based, automated deep learning model with a fusion architecture to facilitate the evaluation and diagnosis of increased left ventricular (LV) wall thickness. Methods and Results: Patients with an established diagnosis of increased LV wall thickness (hypertrophic cardiomyopathy (HCM), cardiac amyloidosis (CA), and hypertensive heart disease (HTN)/others) between 1/2015 and 11/2019 at Mayo Clinic Arizona were identified. The cohort was divided into 80%/10%/10% for training, validation, and testing sets, respectively. Six baseline TTE views were used to optimize a pre-trained InceptionResnetV2 model. Each model output was used to train a meta-learner under a fusion architecture. Model performance was assessed by multiclass area under the receiver operating characteristic curve (AUROC). A total of 586 patients were used for the final analysis (194 HCM, 201 CA, and 191 HTN/others). The mean age was 55.0 years, and 57.8% were male. Among the individual view-dependent models, the apical 4-chamber model had the best performance (AUROC: HCM: 0.94, CA: 0.73, and HTN/other: 0.87). The final fusion model outperformed all the view-dependent models (AUROC: HCM: 0.93, CA: 0.90, and HTN/other: 0.92). Conclusion: The echo-based InceptionResnetV2 fusion model can accurately classify the main etiologies of increased LV wall thickness and can facilitate the process of diagnosis and workup.
Developing an Echocardiography-Based, Automatic Deep Learning Framework for the Differentiation of Increased Left Ventricular Wall Thickness Etiologies

No container title available | September 7, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.166257188.84471102/v1

Aims Increased LV wall thickness is frequently encountered in transthoracic echocardiography (TTE). While accurate and early diagnosis is clinically important, given the differences in available therapeutic options and prognosis, an extensive workup is often required to establish the diagnosis. We propose the first echo-based, automated deep learning model with a fusion architecture to facilitate the evaluation and diagnosis of increased left ventricular (LV) wall thickness. Methods and Results Patients with an established diagnosis of increased LV wall thickness (hypertrophic cardiomyopathy (HCM), cardiac amyloidosis (CA), and hypertensive heart disease (HTN)/others) between 1/2015 to 11/2019 at Mayo Clinic Arizona were identified. The cohort was divided into 80%/10%/10% for training, validation, and testing sets, respectively. Six baseline TTE views were used to optimize a pre-trained InceptionResnetV2 model. Each model output was used to train a meta-learner under a fusion architecture. Model performance was assessed by multiclass area under the receiver operating characteristic curve (AUROC). A total of 586 patients were used for the final analysis (194 HCM, 201 CA, and 191 HTN/others). The mean age was 55.0 years, and 57.8% were male. Among the individual view-dependent models, the apical 4 chamber model had the best performance (AUROC: HCM: 0.94, CA: 0.73, and HTN/other: 0.87). The final fusion model outperformed all the view-dependent models (AUROC: CA: 0.90, HCM: 0.93, and HTN/other: 0.92). Conclusion The echo-based InceptionResnetV2 fusion model can accurately classify the main etiologies of increased LV wall thickness and can facilitate the process of diagnosis and workup.
Papillary fibroelastoma of the pulmonary valve: a 14-year follow-up

No container title available | August 9, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.166004382.22122672/v1

Primary cardiac tumors are exceedingly rare. Among them, papillary fibroelastomas (PFEs) are the third most common. These tumors are often incidental findings but can also precipitate a myriad of clinical presentations, mainly embolic events. Most common in the left-sided valves, PFEs rarely occur in the right side of the heart. They are usually resected surgically following diagnosis, thwarting assessment of their natural history. We present the case of a woman diagnosed with pulmonary valve PFE following recurrent pulmonary embolism who did not undergo surgery, allowing for an extended follow-up of the condition.
The Use of New Emerging Technology in Echocardiography-Glass View

Korean Circulation Journal | November 19, 2021 | Volume: 52 | Issue: 1 | Pages: 87

10.4070/kcj.2021.0341 | PMID 34989196

High Prevalence of Severe Aortic Stenosis in Low-Flow State Associated With Atrial Fibrillation

Circulation: Cardiovascular Imaging | July 12, 2021 | Volume: 14 | Issue: 7 | Pages: No page available

10.1161/circimaging.120.012453 | PMID 34250815

Background: Atrial fibrillation (AF) is a low-flow state and may underestimate aortic stenosis (AS) severity. Single-high Doppler signals (HS) consistent with severe AS (peak velocity ≥4 m/s or mean gradient ≥40 mm Hg) are averaged down in current practice. The objective for the study was to determine the significance of HS in AF low-gradient AS (LGAS). Methods: One thousand five hundred forty-one patients with aortic valve area ≤1 cm 2 and left ventricular ejection fraction ≥50% were identified and classified as high-gradient AS (HGAS) (≥40 mm Hg) and LGAS (<40 mm Hg), and AF versus sinus rhythm (SR). Available computed tomography aortic valve calcium scores (AVCS) were retrieved from the medical record. Outcomes were assessed. Results: Mean age was 76±11 years, female 47%. Mean gradient was 51±12 in SR-HGAS, 48±10 in AF-HGAS, 31±5 in SR-LGAS, and 29±7 mm Hg in AF-LGAS, all P ≤0.001 versus SR-HGAS; HS were present in 33% of AF-LGAS. AVCS were available in 34%. Compared with SR-HGAS (2409 arbitrary units; interquartile range, 1581–3462) AVCS were higher in AF-HGAS (2991 arbitrary units; IQR1978–4229, P =0.001), not different in AF-LGAS (2399 arbitrary units; IQR1817–2810, P =0.47), and lower in SR-LGAS (1593 arbitrary units; IQR945–1832, P <0.001); AVCS in AF-LGAS were higher when HS were present ( P =0.048). Compared with SR-HGAS, the age-, sex-, comorbidity index-, and time-dependent aortic valve replacement-adjusted mortality risk was higher in AF-HGAS (hazard ratio=1.82 [1.40–2.36], P <0.001) and AF-LGAS with HS (hazard ratio=1.54 [1.04–2.26], P =0.03) but not different in AF-LGAS without HS or SR-LGAS (both P =not significant). Conclusions: Severe AS was common in AF-LGAS. AVCS in AF-LGAS were not different from SR-HGAS. AVCS were higher and mortality worse in AF-LGAS when HS were present.
1049 High single-beat Doppler signals in low-gradient aortic stenosis are associated with higher aortic valve calcium

European Heart Journal - Cardiovascular Imaging | January 17, 2020 | Volume: 21 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jez319.641

Abstract Funding Acknowledgements Mayo Clinic Background Variability in Doppler signals is common in patients with atrial fibrillation (AF) and AF is common in low-gradient AS (LGAS). Presence of high single beat Doppler signals (peak velocity ≥4m/s or mean gradient ≥40mmHg) is not factored into decision-making in low-gradient aortic stenosis (LGAS). Objective Determine prevalence of at least one high Doppler signal in AF LGAS and its relationship to computed tomography aortic valve calcium score (AVCS) versus sinus rhythm (SR) high-gradient aortic stenosis (HGAS). Methods Consecutive patients with aortic valve area ≤1cm2 and left ventricular ejection fraction ≥50% during echo were identified (January 1, 2012-December 31, 2016). At least three consecutive Doppler signals were averaged in sinus rhythm (SR) and five in atrial fibrillation (AF). Results Of 1,854 patients, age 76± 11 years, male 52%, 301/1,854 (16%) were in AF and LGAS was present in 122/301 (41%). At least one high Doppler signal in AF LGAS was present in 43/122 (35%). AVCS within 1 year of echo was available for 36% of patient with SR HGAS and 34% of AS LGAS. Median AVCS was not different in SR HGAS 2424 (IQR 1623, 3445) vs AF LGAS with at least one high Doppler signal 2509 [IQR1547, 3119], p =0.10 AVCS threshold for severe AS (men &gt;2000 women &gt;1200) was met in 80% SR HGAS vs 86% AF LGAS with high signals. Conclusions High Doppler signals in AF LGAS are associated with high AVCS more frequently exceeding thresholds for severe AS. Single-beat high Doppler signals instead of the average correlate better with AVCS and classic HGAS.
Echocardiographic mimicker of thrombus on a mechanical aortic valve prosthesis due to cavitation: A paradoxical phenomenon of pressure recovery

Echocardiography | June 18, 2019 | Volume: 36 | Issue: 7 | Pages: 1397-1400

10.1111/echo.14403 | PMID 31209920

AbstractWe describe a case of a mass‐like echocardiographic density on a mechanical prosthetic aortic valve. We initially suspected a thrombus vs vegetation on transthoracic echocardiography, but after transesophageal echocardiography, the density was subsequently determined to be cavitation by reviewing the initial images in slow motion.