Citations 56

Diagnostic and therapeutic value of implantable loop recorder: A tertiary care center experience

Pacing and Clinical Electrophysiology | October 25, 2018 | Volume: 42 | Issue: 1 | Pages: 38-45

10.1111/pace.13533 | PMID 30357866

AbstractBackgroundImplantable loop recorders (ILRs) are effective in achieving symptom‐rhythm correlation. However, diagnostic yield in routine clinical practice is not well established.MethodsPatients undergoing ILR implantation between April 2010 and May 2015 were included. All devices were enrolled in remote monitoring with automatic arrhythmia detection and P sense algorithms switched “ON.” Symptom‐rhythm correlation was assessed and changes in management were recorded.ResultsA total of 312 patients (57% male, age 53 ± 22 years; median CHADS2VaSc score = 1) were included in this study. ILRs were implanted for evaluation of syncope in 206 (66.0%), presyncope in 23 (7.4%), unexplained palpitations in 51 (16.3%), and cryptogenic stroke in 27 (8.7%) patients. ILR monitoring yielded a diagnosis that changed management strategy in 146 (46.8%) patients over a median of 12 (1‐42) months. Out of 163 (52.2%) patients with symptoms during the monitoring period, 100 (61.3%) had an arrhythmia. ILR was useful in ruling out an arrhythmic cause for symptoms in 63 (38.7%) patients. ILR results led to pacemaker implantation in 23 patients (7.4% overall and 11.2% of those with syncope) after median follow‐up of 3 months. A new diagnosis of atrial fibrillation was made in 38 (12.2%) patients, 11 of whom were initiated on oral anticoagulants. ILR results led to pacemaker implantation in 31 patients (9.9% overall and 19.0% of those with syncope) after median follow‐up of 3 months. A new diagnosis of atrial fibrillation was made in 38 (12.2%) patients, nine of whom were initiated on oral anticoagulants. Overall, ILR led to a change in management in 47% patients with a number needed to implant of 2.1 to change management.ConclusionILR monitoring is effective in achieving symptom‐rhythm correlation and results in changes in management in nearly half of implanted patients. Additional studies are needed to evaluate cost efficacy of ILR and the optimal monitoring duration.
P3698Correlation of lead length with procedural safety outcomes of magnetic resonance imaging in patients with legacy pacemakers and defibrillators

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy563.p3698

Leadless pacemaker used as long-term temporary therapy in Lyme carditis with high-grade atrioventricular block

EP Europace | July 14, 2018 | Volume: 21 | Issue: 1 | Pages: 8-8

10.1093/europace/euy175 | PMID 30059962

Level of block: atrioventricular node, infra-Hisian, or intramyocardial?

EP Europace | July 14, 2018 | Volume: 21 | Issue: 2 | Pages: 321-321

10.1093/europace/euy163 | PMID 30020430

Intrapulmonary Vein Ablation Without Stenosis: A Novel Balloon‐Based Direct Current Electroporation Approach

Journal of the American Heart Association | July 9, 2018 | Volume: 7 | Issue: 14 | Pages: No page available

10.1161/jaha.118.009575 | PMID 29987121

Background Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period. Methods and Results Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG‐gated 100 μs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present. Conclusions Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27‐day survival period using this balloon‐based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.
Percutaneous epicardial pacing using a novel transverse sinus device

Journal of Cardiovascular Electrophysiology | June 8, 2018 | Volume: 29 | Issue: 9 | Pages: 1308-1316

10.1111/jce.13661 | PMID 29882395

AbstractBackgroundTransvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS).Methods and resultsWe designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof‐of‐concept and 5 additional acute canine experiments.The TS device recorded ventricular and atrial electrograms. The median amplitude of near‐field ventricular electrograms was 3.3 mA (IQR 2.0–4.3) and of near‐field atrial electrograms was 2.1 mA (IQR 1.3–2.2). The median ventricular threshold (N = 30) was 1.1 mA (IQR 0.7–3.1) at a median pulse width of 0.5 ms (IQR 0.5–0.5). The median atrial threshold (N = 10) was 2.4 mA (IQR 1.1–7.8) at a median pulse width of 0.5 ms (IQR 0.5–0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications.ConclusionsThis study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.
Right Ventricular Dysfunction and Long-Term Risk of Sudden Cardiac Death in Patients With and Without Severe Left Ventricular Dysfunction

Circulation: Arrhythmia and Electrophysiology | May 16, 2018 | Volume: 11 | Issue: 6 | Pages: No page available

10.1161/circep.117.006091 | PMID 29769224

Background: Right ventricular systolic dysfunction (RVD) often coexists with various cardiopulmonary diseases. However, the association between RVD and risk of sudden cardiac death (SCD) has not been well studied. This study examined the risk of SCD associated with RVD in patients with heterogeneous underlying cardiac diseases. Methods: The Mayo Clinic cardiac care unit database included 5463 consecutive patients with complete echocardiographic evaluation to assess right ventricular systolic function and RVD severity. Prospective surveillance follow-up was obtained for all patients. SCD was adjudicated when a malignant ventricular arrhythmia was documented as the primary rhythm leading to death. RESULTS: The prevalence of mild RVD and moderate-severe RVD was 14.9% and 17.1%, respectively. Patients with RVD were more likely to have a history of congestive heart failure, cardiac arrest, pulmonary disease, and lower baseline left ventricular ejection fraction compared with those with normal right ventricular systolic function. During a median follow-up of 14 months, the incidence of SCD was highest in patients with moderate-severe RVD (7.4% versus 4.4% in mild RVD versus 1.6% in normal right ventricular function; P <0.001). After adjustment for baseline characteristics, mild RVD (adjusted hazard ratio, 1.57; P =0.046) and moderate-severe RVD (adjusted hazard ratio, 1.91; P =0.006) were independently associated with an increased risk of SCD. Moderate-severe RVD remained an independent predictor of SCD for patients with left ventricular ejection fraction >35% without or with preexisting implantable cardioverter-defibrillator (adjusted hazard ratio, 4.12; P =0.003 and adjusted hazard ratio, 5.04; P <0.001, respectively). Conclusions: Presence of RVD in patients with a history of preexisting cardiac disease is an independent predictor of SCD irrespective of left ventricular ejection fraction.
P1218Incidence and Risk Factors for Renal Dysfunction after Direct Current Cardioversion of Atrial Fibrillation

EP Europace | March 19, 2018 | Volume: 20 | Issue: suppl_1 | Pages: i239-i239

10.1093/europace/euy015.700

207Clinical utility of performing magnetic resonance imaging in patients with cardiac implantable electronic devices in situ

EP Europace | March 19, 2018 | Volume: 20 | Issue: suppl_1 | Pages: i22-i23

10.1093/europace/euy015.056

Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices

Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/circep.117.005480 | PMID 29321191

Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.