Magnetic resonance elastography (MRE) is an imaging technology that has been available as an FDA-cleared upgrade to MRI systems since 2009. Worldwide, MRE technology has been installed on approximately 1000 MRI systems. In October 2017, the AMA approved the creation of a CPT code for MRE. In MRE, propagating shear waves in the range of 30–300 Hz are generated in tissue, and imaged with a phase contrast MRI technique. The wave images are processed with an inversion algorithm to generate cross-sectional images quantitatively depicting the complex shear modulus of tissue. The main application of MRE is currently in noninvasive diagnosis of chronic liver disease. Published studies have established the MRE is the most accurate and technically successful non-invasive modality for diagnosing liver fibrosis. Many other promising applications of MRE are being explored by investigators around the world, including assessment of diseases of the brain, heart, lung, and muscle and tumors of breast, liver, prostate, liver, and other organs. The new applications that closest adoption in clinical practice are (1) assessment of brain disease and (2) advanced diagnosis of liver disease. These new applications require acquisition sequences and processing algorithms that are more advanced than the current product MRE techniques.
Pancreatic Stiffness Quantified with MR Elastography: Relationship to Postoperative Pancreatic Fistula after Pancreaticoenteric Anastomosis
PurposeTo assess the success rate, image quality, and the ability to stage liver fibrosis of a standard 2D gradient‐recalled echo (GRE) and four different spin‐echo (SE) magnetic resonance elastography (MRE) sequences in patients with different liver iron concentrations.Materials and MethodsA total of 332 patients who underwent 3T MRE examinations that included liver fat and iron quantification were enrolled, including 136 patients with all five MRE techniques. Thirty‐four patients had biopsy results for fibrosis staging. The liver stiffness, region of interest area, image quality, and success rate of the five sequences were compared in 115/136 patients. The area under the receiver operating characteristic curves (AUCs) and the accuracies for diagnosing early‐stage fibrosis and advanced fibrosis were compared. The effect of BMI (body mass index), the R2* relaxation time, and fat fraction on the image quality and liver stiffness measurements were analyzed.ResultsThe success rates were significantly higher in the four SE sequences (99.1–100%) compared with GRE MRE (85.3%) (all P < 0.001). There were significant differences of the mean ROI area between every pair of sequences (all P < 0.0001). There were no significant differences in the AUC of the five MRE sequences for discriminating advanced fibrosis (10 P‐values ranging from 0.2410–0.9171). R2* had a significant effect on the success rate and image quality for the noniron 2D echo‐planar imaging (EPI), 3D EPI and 2D GRE (all P < 0.001) sequences. BMI had a significant effect on the iron 2D EPI (P = 0.0230) and iron 2D SE (P = 0.0040) sequences.ConclusionAll five techniques showed good diagnostic performance in staging liver fibrosis. The SE MRE sequences had higher success rates and better image quality than GRE MRE in 3T clinical hepatic imaging.Level of Evidence: 3Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2018;47:976–987.
Quantitative assessment of lung stiffness in patients with interstitial lung disease using MR elastography
Journal of Magnetic Resonance Imaging | July 13, 2017 | Volume: 46 | Issue: 2 | Pages: No page available
PurposeTo investigate the use of magnetic resonance elastography (MRE) in the quantitative assessment of pulmonary fibrosis by comparing quantitative shear stiffness measurements of lung parenchyma in patients diagnosed with fibrotic interstitial lung disease (ILD) and healthy controls.Materials and MethodsA 1.5T spin‐echo, echo planar imaging MRE (SE‐EPI MRE) pulse sequence was utilized to assess absolute lung shear stiffness in 15 patients with diagnosed ILD and in 11 healthy controls. Data were collected at residual volume (RV) and total lung capacity (TLC). Spirometry data were obtained immediately prior to scanning. To test for statistical significance between RV and TLC shear stiffness estimates a two‐sample t‐test was performed. To assess variability within individual subject shear stiffness estimates, the intraclass correlation coefficient (ICC) and Krippendorff's alpha were calculated.ResultsPatients with ILD exhibited an average (±1 standard deviation) shear stiffness of 2.74 (±0.896) kPa at TLC and 1.32 (±0.300) kPa at RV. The corresponding values for healthy individuals were 1.33 (±0.195) kPa and 0.849 (±0.250) kPa, respectively. The difference in shear stiffness between RV and TLC was statistically significant (P < 0.001). At TLC, the ICC and alpha values were 0.909 and 0.887, respectively. At RV, the ICC and alpha values were 0.852 and 0.862, respectively.ConclusionIn subjects with known fibrotic interstitial lung disease, parenchymal shear stiffness is increased when compared to normal controls at both RV and TLC, with TLC demonstrating the most significant difference. MRE‐derived parenchymal shear stiffness is a promising new noninvasive imaging‐based biomarker of interstitial lung disease.Level of Evidence:1J. MAGN. RESON. IMAGING 2017;46:1–1
MR Elastography Demonstrates Unique Regional Brain Stiffness Patterns in Dementias
American Journal of Roentgenology | June 1, 2017 | Volume: 209 | Issue: 2 | Pages: 403-408
Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two‐dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross‐validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross‐validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%‐81.1%). Overall cross‐validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%‐94.5%) for center 1, 90.0% (95% CI, 81.9%‐95.3%) for center 2, and 86.7% (95% CI, 77.9%‐92.9%) for automated analysis. Conclusion : 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (H epatology 2017;66:1474–1485)
Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
Magnetic Resonance in Medicine | May 10, 2017 | Volume: 79 | Issue: 2 | Pages: 1043-1051