Citations 132

Assessment of in vivo laser ablation using MR elastography with an inertial driver

Magnetic Resonance in Medicine | July 31, 2013 | Volume: 72 | Issue: 1 | Pages: 59-67

10.1002/mrm.24891 | PMID 23904298

MR elastography derived shear stiffness-a new imaging biomarker for the assessment of early tumor response to chemotherapy

Magnetic Resonance in Medicine | June 25, 2013 | Volume: 71 | Issue: 5 | Pages: 1834-1840

10.1002/mrm.24825 | PMID 23801372

Peroneal Tendon Injuries

Foot & Ankle International | March 3, 2013 | Volume: 19 | Issue: 5 | Pages: 280-288

10.1177/107110079801900503 | PMID 9622417

Injury to the peroneal tendons is a frequently overlooked cause of persistent lateral ankle pain after trauma. Peroneal tendon anatomy, biomechanics, diagnostic studies, and traumatic disorders were reviewed.
MR Elastography of Breast Cancer: Preliminary Results

American Journal of Roentgenology | February 28, 2013 | Volume: 178 | Issue: 6 | Pages: 1411-1417

10.2214/ajr.178.6.1781411 | PMID 12034608

Autocorrection of Three-Dimensional Time-of-Flight MR Angiography of the Circle of Willis

American Journal of Roentgenology | February 28, 2013 | Volume: 176 | Issue: 2 | Pages: 513-518

10.2214/ajr.176.2.1760513 | PMID 11159106

Hepatic and splenic stiffness augmentation assessed with MR elastography in an in vivo porcine portal hypertension model

Journal of Magnetic Resonance Imaging | February 15, 2013 | Volume: 38 | Issue: 4 | Pages: 809-815

10.1002/jmri.24049 | PMID 23418135

PurposeTo investigate the influence of portal pressure on the shear stiffness of the liver and spleen in a well‐controlled in vivo porcine model with magnetic resonance elastography (MRE). A significant correlation between portal pressure and tissue stiffness could be used to noninvasively assess increased portal venous pressure (portal hypertension), which is a frequent clinical condition caused by cirrhosis of the liver and is responsible for the development of many lethal complications.Materials and MethodsDuring multiple intraarterial infusions of Dextran‐40 in three adult domestic pigs in vivo, 3D abdominal MRE was performed with left ventricle and portal catheters measuring blood pressure simultaneously. Least‐squares linear regressions were used to analyze the relationship between tissue stiffness and portal pressure.ResultsLiver and spleen stiffness have a dynamic component that increases significantly following an increase in portal or left ventricular pressure. Correlation coefficients with the linear regressions between stiffness and pressure exceeded 0.8 in most cases.ConclusionThe observed stiffness–pressure relationship of the liver and spleen could provide a promising noninvasive method for assessing portal pressure. Using MRE to study the tissue mechanics associated with portal pressure may provide new insights into the natural history and pathophysiology of hepatic diseases and may have significant diagnostic value in the future. J. Magn. Reson. Imaging 2013;38:809–815. © 2013 Wiley Periodicals, Inc.
MR elastography of the human abdominal aorta: A preliminary study

Journal of Magnetic Resonance Imaging | January 31, 2013 | Volume: 38 | Issue: 6 | Pages: 1549-1553

10.1002/jmri.24056 | PMID 23371244

PurposeTo investigate the feasibility of using MR elastography (MRE) for the evaluation of the stiffness of in vivo aortic wall.Materials and MethodsTo validate the experimental approach for imaging the aorta in vivo, a gel phantom with an embedded porcine aorta was imaged in the presence of fluid flow within the aorta. The potential changes in the elasticity of the vessel wall with changes in pressure were investigated. The feasibility of performing MRE of abdominal aorta was assessed in five volunteers (age, 22–40 years; body mass index, 21.5–25.2 kg/m2). The pulse‐gated cine MRE technique was used to study the wave propagation along the aorta throughout the cardiac cycle and provide estimates of aortic stiffness in diastole.ResultsIn the phantom study, the wave propagation was well visualized within the porcine aorta embedded in the gel phantom. An increase of the Young's modulus‐wall thickness (E*t) product with the increase in static pressure was observed. In the in vivo study, the waves were well visualized within the lumen of abdominal aorta in the five volunteers in diastolic phase, but they were not well visualized during systole.ConclusionMRE is feasible for noninvasively assessing the stiffness of the abdominal aorta and merits further investigation. J. Magn. Reson. Imaging 2013;38:1549–1553. © 2013 Wiley Periodicals, Inc.
Automated liver stiffness measurements with magnetic resonance elastography

Journal of Magnetic Resonance Imaging | December 21, 2012 | Volume: 38 | Issue: 2 | Pages: 371-379

10.1002/jmri.23980 | PMID 23281171

PurposeTo provide a fully automated algorithm for obtaining stiffness measurements from hepatic magnetic resonance elastography (MRE) images that are consistent with measurements performed by expert readers.Materials and MethodsAn initial liver contour was found using an adaptive threshold and expanded using an active contour to select a homogeneous area of the liver. The confidence map generated during the stiffness calculation was used to select a region of reliable wave propagation. The average stiffness within the automatically generated region of interest (ROI) was compared to measurements by two trained readers in a set of 88 clinical test cases ranging from healthy to severely fibrotic.ResultsThe stiffness measurements reported by the readers differed by −6.76% ± 22.8% (95% confidence) and had an intraclass correlation coefficient (ICC) of 0.972 (P < 0.05). The algorithm and the more experienced reader differed by 4.32% ± 14.9 with an ICC of 0.987.ConclusionThe automated algorithm performed reliably, even though MRE acquisitions often have motion artifacts present. The correlation between the automated measurements and those from the trained readers was superior to the correlation between the readers. J. Magn. Reson. Imaging 2013;38:371–379. © 2013 Wiley Periodicals, Inc.
Preoperative assessment of meningioma stiffness using magnetic resonance elastography

Journal of Neurosurgery | October 19, 2012 | Volume: 118 | Issue: 3 | Pages: 643-648

10.3171/2012.9.jns12519 | PMID 23082888

Object The object of this study was to determine the potential of magnetic resonance elastography (MRE) to preoperatively assess the stiffness of meningiomas. Methods Thirteen patients with meningiomas underwent 3D brain MRE examination to measure stiffness in the tumor as well as in surrounding brain tissue. Blinded to the MRE results, neurosurgeons made a qualitative assessment of tumor stiffness at the time of resection. The ability of MRE to predict the surgical assessment of stiffness was tested using a Spearman rank correlation. Results One case was excluded due to a small tumor size. In the remaining 12 cases, both tumor stiffness alone (p = 0.023) and the ratio of tumor stiffness to surrounding brain tissue stiffness (p = 0.0032) significantly correlated with the surgeons' qualitative assessment of tumor stiffness. Results of the MRE examination provided a stronger correlation with the surgical assessment of stiffness compared with traditional T1- and T2-weighted imaging (p = 0.089), particularly when considering meningiomas of intermediate stiffness. Conclusions In this cohort, preoperative MRE predicted tumor consistency at the time of surgery. Tumor stiffness as measured using MRE outperformed conventional MRI because tumor appearance on T1- and T2-weighted images could only accurately predict the softest and hardest meningiomas.
Neuropilin-1 Stimulates Tumor Growth by Increasing Fibronectin Fibril Assembly in the Tumor Microenvironment

Cancer Research | June 27, 2012 | Volume: 72 | Issue: 16 | Pages: 4047-4059

10.1158/0008-5472.can-11-3907 | PMID 22738912

Abstract The tumor microenvironment, including stromal myofibroblasts and associated matrix proteins, regulates cancer cell invasion and proliferation. Here, we report that neuropilin-1 (NRP-1) orchestrates communications between myofibroblasts and soluble fibronectin that promote α5β1 integrin–dependent fibronectin fibril assembly, matrix stiffness, and tumor growth. Tumor growth and fibronectin fibril assembly were reduced by genetic depletion or antibody neutralization of NRP-1 from stromal myofibroblasts in vivo. Mechanistically, the increase in fibronectin fibril assembly required glycosylation of serine 612 of the extracellular domain of NRP-1, an intact intracellular NRP-1 SEA domain, and intracellular associations between NRP-1, the scaffold protein GIPC, and the nonreceptor tyrosine kinase c-Abl that augmented α5β1 fibronectin fibril assembly activity. Analysis of human cancer specimens established an association between tumoral NRP-1 levels and clinical outcome. Our findings indicate that NRP-1 activates the tumor microenvironment, thereby promoting tumor growth. These results not only identify new molecular mechanisms of fibronectin fibril assembly but also have important implications for therapeutic targeting of the myofibroblast in the tumor microenvironment. Cancer Res; 72(16); 4047–59. ©2012 AACR.