Citations 98

Optimizing Emergency Department Workflow Using Radio Frequency Identification Device (RFID) Data Analytics

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3402

Emergency Department (ED) is a complex care delivery environment in a hospital that provides time sensitive urgent and lifesaving care [1]. Emergency medicine is an unscheduled practice and therefore providers experience extreme fluctuations in their workload. ED crowding is a major concern that affects the efficacy of the ED workflow, which often is challenged by long wait times, overuse of observation units, patients either leaving without being seen by a provider and non-availability of inpatient beds to accommodate patients after diagnosis [2]. Evaluating ED workflow is a challenging task due to its chaotic nature, with some success using time-motion studies and novel capacity management tools are nowadays becoming common in ED to address workflow related issues [3]. Several studies reveal that Electronic Medical Record (EMR) adoption has not resulted in significant ED workflow improvements nor reduced the cost of ED operations. Since raw EMR data does not offer operational and clinical decision making insights, advanced EMR data analytics are often sought to derive actionable intelligence from EMR data that can provide insights to improve ED workflow. Improving ED workflow has been an important topic of research because of its great potential to optimize the urgent care needed for the patients and at the same time save time and cost. Radio Frequency Identification Device (RFID) is a wireless automatic identification and data capture technology device that has the potential for improving safety, preventing errors, saving costs, and increasing security and therefore improving overall organizational performance. RFID technology use in healthcare has opened a new space in healthcare informatics research that provides novel data to identify workflow process pitfalls and provide new directions [4]. The potential advantages of RFID adoption in healthcare and especially in ED has been well recognized to save costs and improve care delivery [5]. However, the large upfront infrastructure costs, need for an integrated health information technology (HIT), advanced analytical tools for big data analysis emerging from RFID and skilled data scientists to tackle the data to derive actionable intelligence discourage many hospitals from adoption RFID technology despite its potential advantages. Our recent pilot study on the RFID data analytics demonstrated the feasibility of quantifying and analyzing two novel variables such as ‘patient alone’ time defined as the total time a patient spends alone without interaction with a health care staff in the ED and ‘provider time’ defined as the total time a patient spends interacting with any health care staff [6]. The study motivated a more comprehensive big data analytics of RFID data which can provide better insights into optimizing ED workflow which can improve the quality of care in the ED and also reduce cost. In this work, the authors attempt to describe the RFID adoption in the ED at the Saint Mary’s Hospital at Mayo Clinic, in Rochester, MN, a level one trauma center both for children and adults as a step towards optimizing ED workflow.
Air Embolism: Diagnosis and Management

Future Cardiology | June 23, 2017 | Volume: 13 | Issue: 4 | Pages: 365-378

10.2217/fca-2017-0015 | PMID 28644058

Feasibility study of cardiac magnetic resonance elastography in cardiac amyloidosis

Amyloid | April 22, 2017 | Volume: 24 | Issue: sup1 | Pages: 161-161

10.1080/13506129.2017.1278689 | PMID 28434361

Regional assessment of in vivo myocardial stiffness using 3D magnetic resonance elastography in a porcine model of myocardial infarction

Magnetic Resonance in Medicine | April 6, 2017 | Volume: 79 | Issue: 1 | Pages: 361-369

10.1002/mrm.26695 | PMID 28382658

Purpose The stiffness of a myocardial infarct affects the left ventricular pump function and remodeling. Magnetic resonance elastography (MRE) is a noninvasive imaging technique for measuring soft‐tissue stiffness in vivo. The purpose of this study was to investigate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE in a porcine model of myocardial infarction, and compare the results with ex vivo uniaxial tensile testing. Methods Myocardial infarct was induced in a porcine model by embolizing the left circumflex artery. Fourteen days postinfarction, MRE imaging was performed in diastole using an echocardiogram‐gated spin‐echo echo‐planar‐imaging sequence with 140‐Hz vibrations and 3D MRE processing. The MRE stiffness and tensile modulus from uniaxial testing were compared between the remote and infarcted myocardium. Results Myocardial infarcts showed increased in vivo MRE stiffness compared with remote myocardium (4.6 ± 0.7 kPa versus 3.0 ± 0.6 kPa, P = 0.02) within the same pig. Ex vivo uniaxial mechanical testing confirmed the in vivo MRE results, showing that myocardial infarcts were stiffer than remote myocardium (650 ± 80 kPa versus 110 ± 20 kPa, P = 0.01). Conclusions These results demonstrate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE. Magn Reson Med 79:361–369, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Cardiac MR elastography for quantitative assessment of elevated myocardial stiffness in cardiac amyloidosis

Journal of Magnetic Resonance Imaging | February 25, 2017 | Volume: 46 | Issue: 5 | Pages: 1361-1367

10.1002/jmri.25678 | PMID 28236336

PurposeTo evaluate if cardiac magnetic resonance elastography (MRE) can measure increased stiffness in patients with cardiac amyloidosis. Myocardial tissue stiffness plays an important role in cardiac function. A noninvasive quantitative imaging technique capable of measuring myocardial stiffness could aid in disease diagnosis, therapy monitoring, and disease prognostic strategies. We recently developed a high‐frequency cardiac MRE technique capable of making noninvasive stiffness measurements.Materials and MethodsIn all, 16 volunteers and 22 patients with cardiac amyloidosis were enrolled in this study after Institutional Review Board approval and obtaining formal written consent. All subjects were imaged head‐first in the supine position in a 1.5T closed‐bore MR imager. 3D MRE was performed using 5 mm isotropic resolution oblique short‐axis slices and a vibration frequency of 140 Hz to obtain global quantitativein vivoleft ventricular stiffness measurements. The median stiffness was compared between the two cohorts. An octahedral shear strain signal‐to‐noise ratio (OSS‐SNR) threshold of 1.17 was used to exclude exams with insufficient motion amplitude.ResultsFive volunteers and six patients had to be excluded from the study because they fell below the 1.17 OSS‐SNR threshold. The myocardial stiffness of cardiac amyloid patients (median: 11.4 kPa, min: 9.2, max: 15.7) was significantly higher (P = 0.0008) than normal controls (median: 8.2 kPa, min: 7.2, max: 11.8).ConclusionThis study demonstrates the feasibility of 3D high‐frequency cardiac MRE as a contrast‐agent‐free diagnostic imaging technique for cardiac amyloidosis.Level of Evidence:2Technical Efficacy:Stage 2J. Magn. Reson. Imaging 2017;46:1361–1367.
Novel Multiscale Frequency Approach to Identify the Pivot Point of the Rotor1

Journal of Medical Devices | May 11, 2016 | Volume: 10 | Issue: 2 | Pages: No page available

10.1115/1.4033148

Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis

Magnetic Resonance in Medicine | March 26, 2016 | Volume: 77 | Issue: 3 | Pages: 1184-1192

10.1002/mrm.26207 | PMID 27016276

Purpose Magnetic resonance elastography (MRE) is a rapidly growing noninvasive imaging technique for measuring tissue mechanical properties in vivo. Previous studies have compared two‐dimensional MRE measurements with material properties from dynamic mechanical analysis (DMA) devices that were limited in frequency range. Advanced DMA technology now allows broad frequency range testing, and three‐dimensional (3D) MRE is increasingly common. The purpose of this study was to compare 3D MRE stiffness measurements with those of DMA over a wide range of frequencies and shear stiffnesses. Methods 3D MRE and DMA were performed on eight different polyvinyl chloride samples over 20–205 Hz with stiffness between 3 and 23 kPa. Driving frequencies were chosen to create 1.1, 2.2, 3.3, 4.4, 5.5, and 6.6 effective wavelengths across the diameter of the cylindrical phantoms. Wave images were analyzed using direct inversion and local frequency estimation algorithm with the curl operator and compared with DMA measurements at each corresponding frequency. Samples with sufficient spatial resolution and with an octahedral shear strain signal‐to‐noise ratio > 3 were compared. Results Consistency between the two techniques was measured with the intraclass correlation coefficient (ICC) and was excellent with an overall ICC of 0.99. Conclusions 3D MRE and DMA showed excellent consistency over a wide range of frequencies and stiffnesses. Magn Reson Med 77:1184–1192, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
In vivo, high‐frequency three‐dimensional cardiac MR elastography: Feasibility in normal volunteers

Magnetic Resonance in Medicine | January 17, 2016 | Volume: 77 | Issue: 1 | Pages: 351-360

10.1002/mrm.26101 | PMID 26778442

Purpose Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three‐dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. Methods The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). Results The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. Conclusion This study motivates future evaluation of high‐frequency 3D MRE in patient populations. Magn Reson Med 77:351–360, 2017. © 2016 Wiley Periodicals, Inc.