Citations 44

New pathological illuminations on 3D transillumination transesophageal echocardiography imaging

Echocardiography | May 13, 2021 | Volume: 38 | Issue: 6 | Pages: 1070-1073

10.1111/echo.15060 | PMID 33982822

AbstractThe use of 3D technology has significantly improved the diagnostic accuracy of echocardiography by overcoming the limitation of 2D echocardiography. Transillumination 3D image post processing technique enhances shadows and contrast of cardiac structures with a movable virtual light source improving further the clarity and detail provided by conventional 3D imaging. In this report, we present 3 cases, one of mobile atherosclerotic aortic root plaque, another of small thrombi on ICD lead, and a third case of bicuspid aortic valve perforation due to infective endocarditis in whom TEE 3D transillumination further improved the diagnostic quality of conventional 3D imaging and lead to accurate clinical diagnosis.
Tricuspid valve regurgitation management with valve replacement Late Presentation of Traumatic Tricuspid Valve Regurgitation after Motor Vehicle Accident -- Role of 3D Echocardiography

No container title available | February 23, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.161410780.09714167/v1

A 51-year-old unrestrained female driver with history of a high-speed motor vehicle accident had been followed due to progressively worsening tricuspid valve regurgitation (TR). Three dimensional (3D0 transesophageal echocardiogram (TEE) showed a TR jet through a perforation in the an avulsed anterior leaflet from the tricuspid valve and another central tricuspid TR jet regurgitation due to tricuspid leafletresulted from malcoaptation of the leaflets from tricuspid annulus annular dilatation.
Reversible cardiac dysfunction in severe COVID‐19 infection, mechanisms and case report

Echocardiography | August 28, 2020 | Volume: 37 | Issue: 9 | Pages: 1465-1469

10.1111/echo.14807 | PMID 32856328

AbstractA previously healthy 49‐year‐old male patient presented with COVID‐19 infection and required mechanical ventilation and extracorporeal membrane oxygenation due to severe hypoxemia. Echocardiography showed cardiac dysfunction with an apical sparing strain pattern, which rapidly normalized within a week. Apical sparing myocardial strain in patients with COVID‐19 infection may suggest reverse‐type stress cardiomyopathy.
Is there a silver lining for US health care from COVID-19 pandemic?

Reviews in Cardiovascular Medicine | July 1, 2020 | Volume: 21 | Issue: 2 | Pages: No page available

10.31083/j.rcm.2020.02.64 | PMID 32706204

The COVID-19 pandemic has had an impact on economy and health care system of every nation. United States has been the hardest hit country both with incidence and absolute mortality from COVID-19. In some of its states the health care system have been stretched to their limits. This has led to a rapid change in the health care practice due to newly approved emergency legislative bills, new state government laws, measures taken by institutions and practices as well as the changing consumer behavior. Some of these adaptations - in particular, the transition of patient care to virtual visits are revolutionary. Increased vigilance by health care organization and workers to minimize the spread of infection to others as well for personal protection may result in lasting behavioral change that will prevent hospital acquired or transmitted infections and may lead to reduced morbidity and mortality from the regular “flu”. The recycling of personal protective equipment and the emerging research showing it a safe practice will reduce health care expenditure. It is quite possible that this pandemic may be the silver lining that will save the US health care from its unsustainable consumption of US gross domestic product.
Detection of LV apical thrombus by three‐dimensional transesophageal echocardiography

Echocardiography | December 16, 2019 | Volume: 37 | Issue: 1 | Pages: 142-146

10.1111/echo.14558 | PMID 31841222

AbstractIntroductionPatients with apical myocardial infarction are at higher risk of developing left ventricular (LV) thrombi. Standard transesophageal echocardiography (TEE) is commonly used in assessing cardiac source of embolic cerebrovascular accident (CVA). Contrast‐enhanced transthoracic echocardiography (TTE) improves sensitivity for thrombus detection compared with noncontrast TTE, and however for LV apical thrombi, contrast‐enhanced magnetic resonance imaging (MRI) and/or contrast‐enhanced computed tomography (CT) outperform both TTE and TEE in some studies.CaseA 67‐year‐old man with history of prior myocardial infarction (MI), four‐vessel coronary artery bypass surgery, congestive heart failure with LV ejection fraction of 30%, and diabetes mellitus presented to our facility with acute right occipital‐parietal stroke and recent history of left lower extremity ischemia. Head and neck MRI and MR angiography found multiple posterior circulation infarcts suggestive of cardio‐embolic etiology. TTE image quality was suboptimal even after contrast use to evaluate for LV thrombus, and due to renal insufficiency, MRI or CT was precluded and 3DTEE identified large LV apical thrombus with mobile components.Conclusion3DTEE may increase the detection of LV apical thrombi as well as evaluating its characteristics by live imaging as well as by offline reconstruction. TEE may be a useful diagnostic modality, especially in patients with decreased renal function, where iodinated contrast for cardiac CT or Gadolinium for MRI may be contraindicated. Multimodality imaging studies may further prove the utility of 3D echocardiographic imaging in the detection of LV apical thrombus.
Echocardiography in transcatheter aortic (Core)Valve implantation: Part 2—Transesophageal echocardiography

Echocardiography | July 7, 2018 | Volume: 35 | Issue: 7 | Pages: 1020-1041

10.1111/echo.14034 | PMID 29981214

Transesophageal echocardiography (TEE) plays a significant role during transcatheter aortic valve implantation (TAVR). 2DTEE allows assessment of anatomy of the aortic valve, aortic root, left ventricular (LV) outflow tract, severity of the aortic valve stenosis (AS), and the presence and severity of other valve stenosis and regurgitation. Left and right ventricular size and global function as well as cardiac hemodynamics pre and post TAVR and LV regional wall motion can be assessed. Three‐dimensional (3D) imaging adds significantly via accurate measurement of aortic annulus that helps select the appropriate valve size. Biplane imaging allows simultaneous assessment of target cardiac structure in two orthogonal views and provides a rapid assessment during and immediately post valve deployment by evaluating stent height, leaflet motion, and the presence and severity of paravalvular leak (PVL). 2DTEE and 3DTEE allow evaluation of mechanism of PVL that helps guide the decision regarding need for balloon post dilation of the implanted valve or valve in valve implantation.
Echocardiography in transcatheter aortic valve implantation—Part 1—Transthoracic echocardiography

Echocardiography | February 1, 2018 | Volume: 35 | Issue: 7 | Pages: 1005-1019

10.1111/echo.13799 | PMID 29388705

Transcatheter aortic valve replacement (TAVR) has been a revolutionary technique in the treatment of degenerative aortic valve stenosis. Selection of appropriate patients and appropriate valve size is crucial for improved patient outcome. Echocardiographic imaging is a critical component for patient selection and plays an important role in the selection of valve size, procedural guidance, and patient follow‐up. This review discusses role of echocardiography in patient selection, device implantation, and postimplant follow‐up for the first‐generation CoreValve as used in pivotal trial. Same TTE imaging principles apply to the second‐ and third‐generation self‐expandable valves as well as the balloon‐expandable valves. Multiple case examples are used to illustrate imaging principles pre‐ and post‐TAVR. In addition, case examples to demonstrate complications post‐TAVR are shown.
Brick and mortar IMT core lab goes automated and online

European Journal of Preventive Cardiology | November 20, 2017 | Volume: 25 | Issue: 2 | Pages: 150-153

10.1177/2047487317743045 | PMID 29154682

Quantitation of valve regurgitation severity by three‐dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography

Echocardiography | May 8, 2017 | Volume: 34 | Issue: 7 | Pages: 992-1001

10.1111/echo.13549 | PMID 28480555

BackgroundQuantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three‐dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE).MethodsWe evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE‐recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade.ResultsMean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively.ConclusionMeasurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves.
Impaired Left and Right Ventricular Systolic and Diastolic Function in Response to Exercise in Patients with Diastolic Dysfunction

Echocardiography | May 31, 2016 | Volume: 33 | Issue: 8 | Pages: 1209-1218

10.1111/echo.13242 | PMID 27241948

BackgroundDiastolic dysfunction (DD) is associated with exercise intolerance. To evaluate mechanisms of exercise intolerance in patients with DD, we performed bicycle stress echocardiography.Method and ResultsDoppler measurements were performed at baseline, during exercise and recovery in 26 patients (58 ± 11 years) with DD and normal left ventricular ejection fraction and 6 normal controls (53 ± 5 years). Compared to controls, patients achieved similar target heart rates but lower METs (5.5 ± 2 vs. 9.8 ± 3, P < 0.01) and a higher peak pulmonary artery pressure (PAP) at peak exercise (50 ± 13 vs. 32 ± 7 mmHg, P < 0.01) despite similar PAP at rest and similar mean blood pressure at peak exercise (110.4 ± 18.0 vs. 106.9 ± 11.4 mmHg, P = NS). In patients versus controls, mitral E/E' was similar at baseline (10 ± 3 vs. 8 ± 1.3, P = NS) but higher at recovery (11 ± 2 vs. 7 ± 2, P < 0.05), % mitral filling time was shorter at baseline, onset, and peak exercise, whereas % LV and RV ejection time was similar to controls throughout exercise. Compared to controls, lateral mitral annular S' (11.8 ± 2.5 cm/sec vs. 14.9 ± 1.9 cm/sec, P < 0.02) and tricuspid annular S' (14.8 ± 4.1 cm/sec vs. 19.4 ± 4.0 cm/sec, P < 0.05) were lower at peak exercise in patients.ConclusionDiastolic filling time is reduced at rest and stress while LV ejection time increases normally during exercise in DD. There is a reduced systolic reserve in LV and RV during exercise in DD. These mechanisms contribute to exercise intolerance and elevation of left atrial and PAP in patients with DD.