Background: Little is known about the relationship between carotid plaque formation and cognitive function in a middle-aged population. Hypothesis: We hypothesize that there will be an association between carotid atherosclerotic burden and cognitive function in middle-aged adults. Aim: The purpose of the present study is to examine the relationship between carotid artery (CA) plaque and cognitive function in middle-aged white and black men and women from the Bogalusa Heart Study (BHS) cohort. Methods: We included a total of 1,107 BHS participants with echocardiography and carotid ultrasound performed between 2013 and 2016. Cognitive function was quantified in a global cognitive score (GCS) comprised of the z standardized sum of 7 neuropsychiatric tests. CA plaque was defined by carotid intima media thickness ≥1.5mm in any segment of the CA including right and left common artery (RCC/LCC), bulbs (RCB/LCB) as well as right and left internal carotid artery (RIC/LIC). We compared demographic, clinical, and echocardiographic characteristics in participants with or without CA plaque and used linear regression analysis for the association between CA and GCS adjusted for age, sex, race and education. Results: Among all, 373 (33.7%) of participants had one or more CA plaque. The most common locations of CA plaque formation differed according to laterality, with 230 (61.7%), 189 (50.7%), 108 (29.0%), 92 (24.7%), 83 (22.3%), 10 (2.7%) participants having plaque in the RCB, LCB, LCA, RIC, LIC, and RCA, respectively. Participants with CA plaque were likely to be older (49.9 vs. 47.2 years), male (52 vs.38.9%), white (70.2 vs.63.4%,), have larger left ventricular (LV) end-diastolic volume (97.4 vs.94 ml) and LV mass index (83.4 vs.76.3 g/m 2 , all p -value<0.01), but similar LV ejection fraction (60.1 vs.60.0%) as compared to those without CA plaque. Moreover, CA is associated with poorer cognitive function (GCS, standardized β coefficient=-0.07; p =0.02) adjusted for age, sex, and race. However, the association was attenuated after adjusting for education. Conclusion: CA plaque was highly prevalent and inversely associated with cognitive function. The association was attenuated by education emphasizing the importance of social determinants in cognitive health.
Abstract 11685: Effects of Pectus Excavatum Surgical Repair on Cardiac Volumes and Systolic Function as Assessed by 3D Transesophageal Echocardiography
Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available
Introduction: The consequences of external cardiovascular compression and cardiac displacement from pectus excavatum (PEx) are debated. The complex geometry of the right (RV) and left ventricle (LV) along with distortion from the extrinsic chest deformity pose significant limitations to reliable assessment of LV and RV volumes and function using transthoracic 2D-echocardiography in this population. Hypothesis: A 3D-echocardiography approach can reliably assess the effects of external cardiac compression and the benefits of surgical correction on RV and LV function in PEx patients. Methods: Adult patients undergoing minimally invasive repair of PEx between Oct-2021 and Feb-2023 were included in this prospective study. Intraoperative transesophageal (TEE) 6 beat full volume video loops incorporating LV and RV were captured and compared before and after surgical correction of the PEx. TomTec Software® was used for offline 3D/4D reconstruction ( Figure 1 shows changes in 3D RV and LV shape pre- and post-surgery). Result: The study included 102 patients (mean age of 32.1 ±11.8 years; Haller index 4.9 ±2.5; 60.8% males). Post PEx repair, there was a significant (p<0.001) increase in the 3D RV volumes, RV ejection fraction (EF), RV stroke volume and RV strain ( Figure 1 ). Additionally, there was a significant improvement in 3D LVEF, 3D LV strain (longitudinal and circumferential), LV twist, and torsion ( Figure 1 ). Conclusion: In this PEx cohort, 3D/4D TEE imaging demonstrated significant increases in RV volumes and in RV and LV systolic function after surgical repair. These findings support the negative cardiovascular consequences of PEx compression and benefits of surgical repair.
Aortic Valve Calcium Score by Computed Tomography as an Adjunct to Echocardiographic Assessment—A Review of Clinical Utility and Applications
Journal of Imaging | November 16, 2023 | Volume: 9 | Issue: 11 | Pages: 250
Aortic valve stenosis (AS) is increasing in prevalence due to the aging population, and severe AS is associated with significant morbidity and mortality. Echocardiography remains the mainstay for the initial detection and diagnosis of AS, as well as for grading of severity. However, there are important subgroups of patients, for example, patients with low-flow low-gradient or paradoxical low-gradient AS, where quantification of severity of AS is challenging by echocardiography and underestimation of severity may delay appropriate management and impart a worse prognosis. Aortic valve calcium score by computed tomography has emerged as a useful clinical diagnostic test that is complimentary to echocardiography, particularly in cases where there may be conflicting data or clinical uncertainty about the degree of AS. In these situations, aortic valve calcium scoring may help re-stratify grading of severity and, therefore, further direct clinical management. This review presents the evolution of aortic valve calcium score by computed tomography, its diagnostic and prognostic value, as well as its utility in clinical care.
Point-of-Care Ultrasound in Detection, Severity and Mechanism of Significant Valvular Heart Disease and Clinical Management
Journal of Clinical Medicine | October 12, 2023 | Volume: 12 | Issue: 20 | Pages: 6474
Background: Early diagnosis of significant valvular heart disease (VHD) enables appropriate implementation of the best therapeutic strategy and follow-up. Cardiac auscultation remains suboptimal in early detection of VHD. The aim of this study was to evaluate the utility of point-of-care ultrasound (POCUS) for early detection of VHD and its severity. Methods: All consecutive patients with VHD who did not have a standard echocardiogram prior to first outpatient cardiology consultation underwent history and physical examination followed by POCUS study by an experienced physician in a general cardiology clinic from June 2017 to August 2022 at our institution. Subsequent standard transthoracic echocardiography (sTTE) was performed as the gold standard. Comparison was performed between POCUS and sTTE for the presence and severity of VHD. sTTE was performed by registered cardiac sonographers and interpreted by another cardiologist blinded to the POCUS results. Results: A total of 77 patients were studied (ge 72 ± 11 years, 58.4% males). A total of 89 significant valvular abnormalities were diagnosed. There were 39 (43.8%) cases of regurgitant VHD, 16 (18.0%) of stenotic VHD and 34 (38.2%) had evaluation for prosthetic valve function. The sensitivity (90.9%; 82.4%; 83.3%; 100%) and specificity (100%; 96.7%; 100%; 100%) were high for detecting ≥ moderate aortic regurgitation (AR), mitral regurgitation (MR), aortic stenosis (AS) and prosthetic valvular abnormality, respectively. The weighted κ coefficient between POCUS and sTTE for the assessment of ≥ moderate MR, AR and AS was 0.81 (95% CI, 0.65–0.97), 0.94 (95% CI, 0.84–1.00) and 0.88 (95% CI, 0.76–1.0), respectively, indicating excellent agreement. Conclusions: POCUS can identify patients with significant VHD and may serve as a powerful screening tool for early detection of significant VHD in the outpatient clinical practice with downstream impact on clinical management of significant VHD.
Three-Dimensional Transesophageal Echocardiography in Percutaneous Catheter-Based Cardiac Interventions
Journal of Clinical Medicine | August 31, 2023 | Volume: 12 | Issue: 17 | Pages: 5664
Cardiac structural and valve interventions have remained surgical procedures for several decades. The ability to directly visualize the region of interest during surgery made imaging of these structures pre- and postsurgery a secondary tool to compliment surgical visualization. The last two decades, however, have seen rapid advances in catheter-based percutaneous structural heart interventions (SHIs). Due to the “blind” nature of these interventions, imaging plays a crucial role in the success of these procedures. Fluoroscopy is used universally in all percutaneous cardiac SHIs and helps primarily in the visualization of catheters and devices. However, success of these procedures requires visualization of intracardiac soft tissue structures. Due to its portable nature and rapid ability to show cardiac structures online, transesophageal echocardiography (TEE) has become an integral tool for guidance for all percutaneous SHI. Transcatheter aortic valve replacement—one of the earliest catheter-based procedures—while initially dependent on TEE, has largely been replaced by preprocedural cardiac CT for accurate assessment of valve sizing. Developments in echocardiography now allow live three-dimensional (3D) visualization of cardiac structures mimicking surgical anatomy during TEE. Besides showing actual 3D intracardiac structures, 3D-TEE allows visualization of the interaction of intracardiac catheters and devices with soft tissue cardiac structures, thereby becoming a “second pair of eyes” for the operator. Real-time 3D-TEE now plays an important role complementing multiplane two dimensional and biplane TEE during such interventions. In this review, we discuss the incremental role of 3D-TEE during various SHIs performed today.
Abstract 15639: Infected Thrombus - An Unusual Etiology of Acute Coronary Syndrome in a Patient With New Onset Atrial Fibrillation
Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available
Background: Coronary embolism (CE) is an uncommon (3%) cause of acute coronary syndromes (ACS) and is often missed. Case Presentation: A 68-year-old woman with a h/o hypertension & breast cancer post lumpectomy 10 yrs ago, presented with generalized weakness, fever (101F), & vomiting without chest pain, dyspnea, or palpitations. She was afebrile, tachycardic (158 beats/min), tachypneic (26 breaths/min) with BP of 98/64 mmHg. Cardiac exam revealed irregularly irregular rhythm, 5 cm jugular venous distension & 3+ bilateral pretibial edema. Labs revealed thrombocytopenia, lactic acidosis, & hyponatremia. High sensitivity-Troponin was 1023 & NT-pro-BNP 19854. EKG showed atrial fibrillation (AF), diffuse ST elevations in the precordial leads & aVR, poor R wave progression & inferior Q waves. Her cardiac cath revealed a large thrombus from mid-left main extending into the LAD with minimal atherosclerotic burden. Intraoperative transesophageal echocardiogram for emergent surgical resection of the thrombus revealed a highly mobile thrombus 2.32x0.6 cm on the aortic aspect originating between L and R coronary cusps and a left atrial appendage thrombus (1.1 cm) with marked spontaneous contrast in LA appendage & LA which was surgically resected. Blood cultures & of coronary thrombus grew Methicillin sensitive Staphylococcus Aureus (MSSA) . Anticoagulation & appropriate antibiotics were initiated. but after a protracted, complicated ICU stay, patient was made comfort care. Discussion/Conclusion: CE should be considered in cases of recurrent coronary thrombus or in the setting of heavy thrombus burden despite a relatively normal coronary vessel. AF is the most common underlying cause of CE causing ACS. Aspiration or surgical thrombectomy should be performed with a high thrombus burden. Thrombus should be sent for pathology to further delineate the source of thrombus.
Abstract 14439: Using Augmented Mean Arterial Pressure to Assess Post-Transcatheter Aortic Valve Replacement Mortality
Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available
Introduction: Post-transcatheter aortic valve replacement (TAVR) outcome of patients is an important research topic. To accurately assess post-TAVR mortality, we examined a family of new echo-parameters (augmented systolic blood pressure (AugSBP) and arterial mean pressure parameters (AugMAP)) derived from blood pressure and aortic valve gradient ( Figure 1 ). Methods: Patients in the Mayo Clinic National Cardiovascular Diseases Registry-TAVR database who underwent TAVR between January 1, 2012, and June 30, 2017, were identified to retrieve baseline clinical, echocardiographic, and mortality data. The median of AugSBP and AugMAP were used to stratify patients in Kaplan-Meier analysis. Results: The final cohort contained 974 patients with a mean age of 81.4±8.3 years old, and 56.6% were male. The mean Society of Thoracic Surgeons risk score was 8.2±5.2. The median follow-up duration was 354 days, and the one-year all-cause mortality rate was 14.2%. Detailed characteristics are summarized in Table 1. AugMAP1 < 102.5 mmHg (median) was associated with a 3-fold risk of all-cause mortality post-TAVR at 1 year (hazard ratio 3.0, 95%confidence interval 2.0-4.5, p<0.0001)( Figure 1 ). Conclusions: Augmented mean arterial pressure provides clinicians with a simple but effective approach to quickly identify patients at risk and potentially improve post-TAVR prognosis.
Abstract 13392: 3D TEE Aids in Assessment of Embolic Stroke Due to Aortic Atherosclerotic Plaque
Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available
Case Presentation: A 69-year-old right-handed man presented with new left-sided weakness and recurrent ischemic strokes. His had history of coronary artery disease, diabetes mellitus, hypertension, dyslipidemia, chronic kidney disease stage 3, obstructive sleep apnea and obesity. Plasma low-density lipoprotein was 127 mg/dL. Brain MRI showed diffusion restriction in the left caudate head, left corona radiata, left anterior lentiform nucleus, and left periventricular white matter from acute to subacute infarction. CT angiogram showed diffuse atheromatous disease in the anterior and posterior circulation, bilateral mild cervical internal carotid artery stenosis, and calcifications in the aortic arch ( Figure 1 ). Transthoracic echocardiogram (TTE) showed mild generalized left ventricular hypokinesis (ejection fraction 45%) without thrombus. Transesophageal echocardiogram (TEE) showed complex mobile atherosclerotic plaques in the aortic arch ( Figure 2 ) after which Apixaban & Clopidogrel were started and statins increased. At 1-year follow-up there was no recurrent stroke. Discussion: This case highlights the role of 3D TEE in the detection of complex aortic arch atherosclerotic plaque with mobile components as the etiology of recurrent embolic stroke. 2D TTE & TEE and CT chest were unable to show mobile components in the aortic arch plaque. Many patients identified as having “cryptogenic stroke” after 2D TTE & TEE may in fact have mobile aortic arch plaques which can only be delineated by 3D TEE, thus reducing the need for further workup and expediting appropriate treatment.
Impact of physician performed point of care ultrasound (POCUS) during first outpatient cardiology consultation on patient management and downstream testing
AbstractBackgroundGoal directed point of care ultrasound (POCUS) is a bedside tool to assist with clinical diagnosis. We examined the impact of POCUS performed by consulting cardiologist (CC) during initial cardiology consult on clinical management and downstream testing.MethodsSixty‐nine study patients (pts) seen in a general cardiology outpatient clinic of a tertiary center by an expert imaging CC were compared to a control group of 65 pts seen by three different CCs without POCUS during the same time‐period, in whom the first standard echo (SE) was performed after the initial visit.ResultsBaseline characteristics were similar between the two groups for age, cardiac risk factors, and referral diagnoses. Echo findings on POCUS and by SE (mean delay of 17.2 days after visit) in the control group were comparable for RV size and function and for valvular heart disease. More patients with lower LVEF, higher LV filling pressures, new regional wall motion abnormalities, and increased aortic root size were present among POCUS group resulting in greater yield of echo abnormalities. There were more cardiovascular medication changes at the first visit (15.3% vs. 5.7%, p < .01), less referral for noninvasive stress testing (10% vs. 29%, p < .01), more advanced cardiac testing and subspecialty referrals (29% vs. 18% pts, p = .06), in the study compared to the control group after cardiology visit.ConclusionPOCUS at time of consultation detects more abnormal echo findings, results in more medication adjustments, less referral for noninvasive stress testing, earlier referral for advanced cardiac diagnostic imaging, and subspecialty cardiac referrals.
Transcatheter Aortic Valve Replacement Prognostication with Augmented Mean Arterial Pressure
Journal of Cardiovascular Development and Disease | April 26, 2023 | Volume: 10 | Issue: 5 | Pages: 192
Background: Post-transcatheter aortic valve replacement (TAVR) patient outcome is an important research topic. To accurately assess post-TAVR mortality, we examined a family of new echo parameters (augmented systolic blood pressure (AugSBP) and arterial mean pressure (AugMAP)) derived from blood pressure and aortic valve gradients. Methods: Patients in the Mayo Clinic National Cardiovascular Diseases Registry-TAVR database who underwent TAVR between 1 January 2012 and 30 June 2017 were identified to retrieve baseline clinical, echocardiographic and mortality data. AugSBP, AugMAP and valvulo-arterial impedance (Zva) (Zva) were evaluated using Cox regression. Receiver operating characteristic curve analysis and the c-index were used to assess the model performance against the Society of Thoracic Surgeons (STS) risk score. Results: The final cohort contained 974 patients with a mean age of 81.4 ± 8.3 years old, and 56.6% were male. The mean STS risk score was 8.2 ± 5.2. The median follow-up duration was 354 days, and the one-year all-cause mortality rate was 14.2%. Both univariate and multivariate Cox regression showed that AugSBP and AugMAP parameters were independent predictors for intermediate-term post-TAVR mortality (all p < 0.0001). AugMAP1 < 102.5 mmHg was associated with a 3-fold-increased risk of all-cause mortality 1-year post-TAVR (hazard ratio 3.0, 95%confidence interval 2.0–4.5, p < 0.0001). A univariate model of AugMAP1 surpassed the STS score model in predicting intermediate-term post-TAVR mortality (area under the curve: 0.700 vs. 0.587, p = 0.005; c-index: 0.681 vs. 0.585, p = 0.001). Conclusions: Augmented mean arterial pressure provides clinicians with a simple but effective approach to quickly identify patients at risk and potentially improve post-TAVR prognosis.