Citations 48

Safety and Risk of Major Complications With Diagnostic Cardiac Catheterization

Circulation: Cardiovascular Interventions | July 9, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007791 | PMID 31284736

Background: We aim to study the incidence of major complications related to procedure defined as in-hospital death, myocardial infarction, stroke, pericardial effusion or tamponade, percutaneous coronary intervention due to iatrogenic coronary dissection, or unplanned bypass surgery within 72 hours after diagnostic left heart catheterization (LHC; primary end point). Furthermore, all causes of in-hospital death after LHC were adjudicated and reported (secondary end point). Methods and Results: Diagnostic LHC procedures (aortic angiography; coronary, including graft, angiography; and left ventricular angiography) from January 1, 2002, through December 31, 2013, were identified using the clinical scheduling system at Mayo Clinic, Rochester, and complications were identified through electronic records. International Classification of Diseases, Ninth Revision billing codes were used. Registration was queried to identify all-cause mortality. All events were reviewed and adjudicated. There were 43 786 diagnostic LHC procedures; 97.3% were coronary angiograms. The mean age of patients was 64.5 years (13.6), and the majority were male (61.5%). Primary end point was seen in 36 (0.082%) procedures or 8.2 of 10 000 LHCs. Combined right sided procedures with LHC did not increase the risk of major complications. Cardiogenic and septic shock, cardiac arrhythmia, and postsurgical complication were the most common causes of in-hospital death after LHC. Conclusions: The overall rates of major complications related to diagnostic cardiac catheterization procedures are extremely rare. The majority of the deaths occurring post-diagnostic LHC procedures were secondary to acute illness rather than directly related to diagnostic procedure.
Outcomes of Patients With Severe Symptomatic Aortic Valve Stenosis After Chest Radiation: Transcatheter Versus Surgical Aortic Valve Replacement

Journal of the American Heart Association | May 24, 2019 | Volume: 8 | Issue: 10 | Pages: No page available

10.1161/jaha.119.012110 | PMID 31124737

Background Patients with symptomatic severe aortic stenosis and a history of chest radiation therapy represent a complex and challenging cohort. It is unknown how transcatheter aortic valve replacement ( TAVR ) compares with surgical aortic valve replacement in this group of patients, which was the objective of this study. Methods and Results We retrospectively reviewed all patients with severe aortic stenosis who underwent either TAVR or surgical aortic valve replacement at our institution with a history of mediastinal radiation (n=55 per group). End points were echocardiographic and clinical outcomes in‐hospital, at 30 days, and at 1 year. Inverse propensity weighting analysis was used to account for intergroup baseline differences. TAVR patients had a higher STS score than surgical aortic valve replacement patients (5.1% [3.2, 7.7] versus 1.6% [0.8, 2.6], P <0.001) and more often ( P <0.01 for all) a history of atrial fibrillation (45.5% versus 12.7%), chronic lung disease (47.3% versus 7.3%), peripheral arterial disease (38.2% versus 7.3%), heart failure (58.2% versus 18.2%), and pacemaker therapy (23.6% versus 1.8%). Postoperative atrial fibrillation was less frequent (1.8% versus 27.3%; P <0.001) and hospital stay was shorter in TAVR patients (4.0 [2.0, 5.0] versus 6.0 [5.0, 8.0] days; P <0.001). The ratio of observed‐to‐expected 30‐day mortality was lower after TAVR as was 30‐day mortality in inverse propensity weighting–adjusted Kaplan–Meier analyses. Conclusions In patients with severe aortic stenosis and a history of chest radiation therapy, TAVR performs better than predicted along with less adjusted 30‐day all‐cause mortality, postoperative atrial fibrillation, and shorter hospitalization compared with surgical aortic valve replacement. These data support further studies on the preferred role of TAVR in this unique patient population.
Low‐Gradient Severe Mitral Stenosis: Hemodynamic Profiles, Clinical Characteristics, and Outcomes

Journal of the American Heart Association | February 22, 2019 | Volume: 8 | Issue: 5 | Pages: No page available

10.1161/jaha.118.010736 | PMID 30793648

Background Optimal management of patients with severe mitral stenosis ( MS ) and low transmitral gradient is incompletely understood. Methods and Results We examined 101 consecutive patients with severe rheumatic MS (mitral valve area ≤1.5 cm 2 ) who underwent balloon valvuloplasty. Low gradient was defined as mean transmitral gradient <10 mm Hg and low flow as stroke volume index ≤35 mL/m 2 by echocardiography. Symptoms and mortality data were collected. Systolic, diastolic, and arterial function were characterized by measuring left ventricular (LV) end‐systolic elastance, LV stiffness constant (β), diastolic capacitance (predicted LV end‐diastolic volume at a common LV filling pressure of 30 mm Hg), and effective arterial elastance. Low gradient (<10 mm Hg) was present in 55 patients, including low flow/low gradient in 11 and normal flow/low gradient in 44 patients, and high gradient was present in 46 patients. Participants with low‐flow/low‐gradient (LG) MS were older with higher rates of atrial fibrillation (64%) and subvalvular thickening, higher afterload, and decreased LV compliance with lower ejection fraction (57±10% versus 65±4% versus 63±6%, P =0.002) but similar end‐systolic elastance compared with patients with normal‐flow/ LG and high‐gradient MS . The normal‐flow/ LG group had larger mitral valve area and lower left atrial pressure by catheterization, as well as favorable long‐term outcomes compared with the low‐flow/ LG and high‐gradient MS group. A total of 40% of patients with LG MS had no symptomatic benefit from valvuloplasty compared with 18% of patients with high‐gradient MS ( P =0.02). Conclusions Presence of low gradient in patients with severe MS was associated with lesser symptomatic benefit from valvuloplasty. In the subset with low stroke volume index, this may be related to independent ventricular‐vascular uncoupling, decreased LV compliance, and high prevalence of atrial fibrillation in addition to intrinsic MS .
Paravalvular leak repair after balloon‐expandable transcatheter mitral valve implantation in mitral annular calcification: Early experience and lessons learned

Catheterization and Cardiovascular Interventions | February 9, 2019 | Volume: 94 | Issue: 5 | Pages: 764-772

10.1002/ccd.28131 | PMID 30737972

AbstractBackgroundTreatment of hemodynamically significant mitral annular calcification (MAC) using transcatheter approaches is in the early learning phase. The occurrence of paravalvular leak (PVL) following transcatheter mitral valve in MAC is common.AimsTo report the initial experience and techniques of percutaneous PVL closure after transcatheter valve in MAC.MethodsThis series includes five consecutive patients who underwent percutaneous PVL closure following transcatheter balloon expandable SAPIEN S3 valve in MAC.ResultsMean patient age was 73.6 ± 5.4 years (4 [80%] female), with average Society of Thoracic Surgeons score of 8.1 ± 2.8%. Three patients had a single PVL defect while two patients had two defects; all were located at the commissural sites. Closure was performed primarily for heart failure in four patients and hemolytic anemia in one patient. Transfemoral transseptal antegrade approach and Amplatz Vascular Plug (AVP)‐II occluders were utilized in all patients. Procedure success was achieved in three patients. One patient developed significant occluder related leaflet impingement and subsequent severe prosthetic mitral regurgitation requiring a second transcatheter mitral valve in valve implantation. The procedure was aborted in one patient due to difficulty crossing PVL defect after balloon post‐dilatation of SAPIEN prosthesis with 10 mL of additional volume. There was no in hospital or 30 day mortality or the need for emergent surgery.ConclusionEarly experience with percutaneous PVL closure of SAPIEN valve in MAC demonstrated feasibility of this approach. Careful procedure planning and monitoring for SAPIEN prosthesis leaflet impingement and frame instability is of utmost importance to increase the chances of procedural success.
Revascularization for Left Main and Multivessel Coronary Artery Disease: Current Status and Future Prospects after the EXCEL and NOBLE Trials

Korean Circulation Journal | April 24, 2018 | Volume: 48 | Issue: 6 | Pages: 447

10.4070/kcj.2018.0078 | PMID 29856140

Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification

Catheterization and Cardiovascular Interventions | January 23, 2018 | Volume: 92 | Issue: 7 | Pages: No page available

10.1002/ccd.27488 | PMID 29359388

AbstractIntroductionThree‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).MethodsEight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
Clinical Conundrum of Coronary Artery Disease and Aortic Valve Stenosis

Journal of the American Heart Association | February 21, 2017 | Volume: 6 | Issue: 2 | Pages: No page available

10.1161/jaha.117.005593 | PMID 28219922

The Forgotten Valve

Circulation | August 17, 2015 | Volume: 132 | Issue: 7 | Pages: No page available

10.1161/circulationaha.115.016315 | PMID 26283605