Citations 48

Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 | PMID 34665654

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
A Simplified Method for the Diagnosis of Constrictive Pericarditis in the Cardiac Catheterization Laboratory

JAMA Cardiology | September 22, 2021 | Volume: 7 | Issue: 1 | Pages: 100

10.1001/jamacardio.2021.3478 | PMID 34550314

Incidence, Causes, and Outcomes Associated With Urgent Implantation of a Supplementary Valve During Transcatheter Aortic Valve Replacement

JAMA Cardiology | May 19, 2021 | Volume: 6 | Issue: 8 | Pages: 936

10.1001/jamacardio.2021.1145 | PMID 34009236

Temporal outcomes of transcatheter mitral valve replacement in native mitral valve disease with annular calcification

Catheterization and Cardiovascular Interventions | February 8, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ccd.29515 | PMID 33539045

30‐day patient reported outcomes can be predicted by change in left atrial pressure and not change in transmitral gradient following MitraClip

Catheterization and Cardiovascular Interventions | January 27, 2021 | Volume: 97 | Issue: 6 | Pages: 1244-1249

10.1002/ccd.29477 | PMID 33502087

AbstractBackgroundChange in left atrial pressure (LAP) has been shown to be associated with symptom improvement post‐MitraClip; however, the association between acute procedural changes in transmitral diastolic mean gradient (MG) compared to LAP and symptom improvement is not well established.Methods164 consecutive patients undergoing MitraClip at Mayo Clinic between June 2014 and May 2018 were included. Preclip and postclip MG and LAP were recorded. Baseline demographics, clinical, and echocardiographic outcomes, including 30‐day New York Heart Association (NYHA) functional status were obtained from patient charts.ResultsMedian age was 81.5 years (IQR: 76.3, 87), 34% were female and 94.5% had NYHA class III and IV functional status at baseline. At baseline, median MG was 4 mmHg (IQR: 3, 5) and LAP was 19 mmHg (IQR: 16, 23.5). Following MitraClip deployment, the median MG was 4 mmHg (IQR: 3, 6) and the median LAP was 17 mmHg (IQR: 14, 21), 69.5% of patients had less than moderate MR. There was no statistically significant association between change in MG and NYHA functional class at 30 days (OR = 0.95, 95% CI: 0.76–1.20). However, a reduction in LAP following MitraClip deployment was significantly associated with improvement in NYHA functional status at 30 days following adjustments for age and sex (aOR 3.36, 95% CI: 1.34–8.65). There was no significant correlation between change in mean LAP and change in MG (p = .98).ConclusionUnlike change in left atrial pressure, change in MG post‐MitraClip was not associated with patient reported outcomes at 30 days and did not correlate with change in left atrial pressure. Long‐term follow up is needed to evaluate the impact of LA pressure on symptoms.
Endovascular snare technique to facilitate delivery of self‐expanding valve during transcatheter aortic valve‐in‐valve replacement in angulated aortas: A case series

Catheterization and Cardiovascular Interventions | January 15, 2021 | Volume: 97 | Issue: 4 | Pages: 736-742

10.1002/ccd.29459 | PMID 33427384

AbstractBackgroundTranscatheter aortic valve‐in‐valve replacement (ViV) has been widely accepted as a less invasive alternative to treat failed aortic surgical or transcatheter bioprosthetic valves. Angulated aortas present an additional challenge, particularly when using self‐expanding transcatheter heart valves (SE‐THV).MethodsTwo patients with failed surgical bioprosthetic aortic valves and one patient with a failed transcatheter bioprosthetic aortic valve underwent transcatheter aortic ViV using SE‐THV. All were deemed high‐risk for surgical aortic valve replacement by a heart team. All three patients had initial failed SE‐THV delivery using a conventional approach with subsequent successful delivery using the endovascular snare technique.ResultsIn Cases 1 and 2, the SE‐THV was biased towards the greater curve of the angulated aorta and behind the outer frame of the bioprosthetic valve frame. An endovascular snare was deployed through a secondary left femoral artery access, and the valve delivery system was advanced through the snare in the ascending aorta. The snare was tightened around the SE‐THV capsule proximal to the hat‐marker, allowing deflection of the SE‐THV and successful delivery. In Case 3, the SE‐THV interacted with the tall frame of a failed SE‐THV. A snare via the left femoral artery was deployed in the descending artery. The SE‐THV was advanced through the snare, and both the snare and SE‐THV were advanced together to the ascending aorta where the SE‐THV was deflected and successfully delivered.ConclusionsThe endovascular snare technique is a feasible option for successful delivery of SE‐THV during transcatheter aortic ViV in failed transcatheter or surgical bioprosthetic valves in angulated aortas.
Utilization of an electronic health record derived elder risk assessment score and outcome in patients undergoing aortic valve replacement

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.3245

Abstract Background Older adults with severe aortic stenosis (AS) are at high risk of mortality unless surgical or transcatheter aortic valve replacement (AVR) is performed. Risk stratification often becomes complicated in frail elders with multi-morbidity, and time constraints limit thorough evaluation of geriatric comorbidities in the outpatient clinic setting. Purpose Utilization of an automated administratively-derived electronic health record (EHR) tool may aid in risk stratification of AS patients undergoing AVR. Methods We reviewed patients with severe AS undergoing AVR at our hospital program and cross-referenced with the Elder Risk Assessment (ERA) score. The ERA score is an administratively abstracted score derived on adults >60 years old followed by general medicine clinic. It contains the following variables: marital status, age, hospitalized days in preceding 2 years, diabetes, coronary disease, heart failure, stroke, pulmonary disease, cancer, and dementia; higher scores indicate greater risk for adverse outcomes. Kaplan-Meier method was used to estimate survival by ERA score tertile. Cox regression was used to test the association of ERA with survival. Results There were 97 patients with severe AS undergoing AVR with ERA scores. Mean age was 80.6 (±6.6) years, 37% were female, average Society of Thoracic Surgery (STS) score was 3.6% (± 2.6), and 7% had transcatheter AVR. Co-morbidities were prevalent and included atrial fibrillation (41%), chronic renal failure (16%), stroke (14%), and diabetes (35%). Over a mean follow-up of 68 months (± 37.9 months), there were 62 deaths. Elevated ERA score was associated with worse long term survival (p=0.016 by log-rank) (Figure 1), with only 49% surviving at 5 years in the highest ERA tertile vs 68% in the lowest ERA tertile. Cox regression demonstrated that the relative risk of death per 6 unit increase in ERA score was 1.54 (95% CI 1.21–1.96, P<0.001) in single variable analysis and 1.43 (95% CI 1.11–1.84, P=0.006) after adjusting for STS score. Conclusions Patients undergoing AVR for severe AS are often co-morbid older adults. An automated EHR derived ERA score was independently associated with survival after accounting for STS score and may streamline and improve risk assessment in these patients. Figure 1 Funding Acknowledgement Type of funding source: Foundation. Main funding source(s): Mayo Clinic
Percutaneous Axillary Intra-aortic Balloon Pump Insertion Technique as Bridge to Advanced Heart Failure Therapy

ASAIO Journal | September 6, 2020 | Volume: 67 | Issue: 4 | Pages: e81-e85

10.1097/mat.0000000000001259 | PMID 33770002

In patients with advanced heart failure (HF), temporary mechanical circulator support (TMCS) is used to improve hemodynamics, via left ventricular unloading, and end-organ function as a bridge to definitive therapy. While listed for cardiac transplantation, use of TMCS may be prolonged, preventing adequate mobility. Here, we describe the technique for placement of a percutaneous axillary intra-aortic balloon pump (IABP) using single-site arterial access to facilitate ambulation and subsequent safe removal without surgery or a closure device. Retrospective review of the experience with this approach at a single institution between September 2017 and February 2020 documented feasibility and safety. Baseline demographics, hemodynamic data, and clinical outcomes were collected. Thirty-eight patients had a total of 56 IABPs placed. There were no significant access site or cerebrovascular complications. One fifth of IABPs (21.4%) had balloon failure or migration, requiring placement of a new device, though no patients had significant complications from balloon failure. The majority (81.6%) of patients in the cohort on axillary IABP support were ambulatory and ultimately received the intended therapy (63.2% transplant, 13.2% durable left ventricular assist device, 5.3% other cardiac surgery). Percutaneous, axillary IABP is feasible and associated with an acceptable complication rate as a bridge to definitive therapy.
A novel technique—Prophylactic septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement (RADIO‐TMVR)

Journal of Cardiovascular Electrophysiology | August 21, 2020 | Volume: 31 | Issue: 11 | Pages: 3048-3055

10.1111/jce.14720 | PMID 32820547

AbstractTranscatheter mitral valve replacement (TMVR) with off‐label use of aortic balloon‐expandable transcatheter heart valves has emerged as a therapeutic option in high‐surgical risk patients with severe mitral annular calcification. Left ventricular outflow tract (LVOT) obstruction post valve deployment is a major limitation. We describe a case of septal reduction therapy using radiofrequency ablation (RFA) when established methods of septal reduction were either ineffective or not feasible. RFA permitted successful enlargement of the LVOT area and subsequent TMVR.
Routine Continuous Electrocardiographic Monitoring Following Percutaneous Coronary Interventions

Circulation: Cardiovascular Interventions | December 30, 2019 | Volume: 13 | Issue: 1 | Pages: No page available

10.1161/circinterventions.119.008290 | PMID 31884835

Background: The clinical utility of routine electrocardiographic monitoring following percutaneous coronary interventions (PCI) is not well studied. Methods: We prospectively evaluated the incidence, cost, and the clinical implications of actionable arrhythmia alarms on telemetry monitoring following PCI. One thousand three hundred fifty-eight PCI procedures (989 [72.8%] for acute coronary syndrome and 369 [27.2%] for stable angina) on patients admitted to nonintensive care unit were identified and divided into 2 groups; group 1, patients with actionable alarms (AA) and group 2, patients with non-AA. AA included (1) ≥3 s electrical pause or asystole; (2) high-grade Mobitz type II atrioventricular block or complete heart block; (3) ventricular fibrillation; (4) ventricular tachycardia (>15 beats); (5) atrial fibrillation with rapid ventricular response; (6) supraventricular tachycardia (>15 beats). Primary outcomes were 30-day all-cause mortality. Cost-savings analysis was performed. Results: Incidence of AA was 2.2% (37/1672). Time from end of procedure to AA was 5.5 (0.5, 24.5) hours. Patients with AA were older, presented with acute congestive heart failure or non–ST-segment–elevation myocardial infarction, and had multivessel or left main disease. The 30-day all-cause mortality was significantly higher in patients with AA (6.5% versus 0.3% in non-AA [ P <0.001]). Applying the standardized costing approach and tailored monitoring per the American Heart Association guidelines lead to potential cost savings of $622 480.95 for the entire population. Conclusions: AA following PCI were infrequent but were associated with increase in 30-day mortality. Following American Heart Association guidelines for monitoring after PCI can lead to substantial cost saving.