Citations 74

Gap-filling method for suppressing grating lobes in ultrasound imaging: Theory and simulation results

The Journal of the Acoustical Society of America | March 18, 2019 | Volume: 145 | Issue: 3 | Pages: EL236-EL242

10.1121/1.5094337 | PMID 31067972

Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired from active elements of an array, RF echo data in unknown and/or inactive elements of array can be created virtually and used to suppress the GL artefact in SA. This letter presents gap-filling (GF) approaches to generate channel data, which are not physically acquired. It is demonstrated that the proposed GF technique can reduce the artefacts of SA by filling the gaps in the array aperture. Simulation results show that the GF technique can suppress the GL level of SA by up to 16 dB. Also, the GF technique can improve the image quality of fully sampled arrays with small number of active elements.
Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study

Sensors | February 25, 2019 | Volume: 19 | Issue: 4 | Pages: 955

10.3390/s19040955 | PMID 30813465

Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in persons with fracture. Using this method, we excited the clavicle or ulna by an ultrasound radiation force pulse which induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The acoustic signals were used for wave velocity estimation based on a cross-correlation technique. To further separate different vibration characteristics, we adopted a variational mode decomposition technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, allowing analysis of the acoustic signals by their constitutive components. This prospective study included 15 patients: 12 with clavicle fractures and three with ulna fractures. Contralateral intact bones were used as controls. Statistical analysis demonstrated that fractured bones can be differentiated from intact ones with a detection probability of 80%. Additionally, we introduce a “healing factor” to quantify the bone healing progress which successfully tracked the progress of healing in 80% of the clavicle fractures in the study.
Non-Local Based Denoising Framework for In Vivo Contrast-Free Ultrasound Microvessel Imaging

Sensors | January 11, 2019 | Volume: 19 | Issue: 2 | Pages: 245

10.3390/s19020245 | PMID 30634614

Vascular networks can provide invaluable information about tumor angiogenesis. Ultrafast Doppler imaging enables ultrasound to image microvessels by applying tissue clutter filtering methods on the spatio-temporal data obtained from plane-wave imaging. However, the resultant vessel images suffer from background noise that degrades image quality and restricts vessel visibilities. In this paper, we addressed microvessel visualization and the associated noise problem in the power Doppler images with the goal of achieving enhanced vessel-background separation. We proposed a combination of patch-based non-local mean filtering and top-hat morphological filtering to improve vessel outline and background noise suppression. We tested the proposed method on a flow phantom, as well as in vivo breast lesions, thyroid nodules, and pathologic liver from human subjects. The proposed non-local-based framework provided a remarkable gain of more than 15 dB, on average, in terms of contrast-to-noise and signal-to-noise ratios. In addition to improving visualization of microvessels, the proposed method provided high quality images suitable for microvessel morphology quantification that may be used for diagnostic applications.
Applications of acoustic radiation force for material characterization and imaging

The Journal of the Acoustical Society of America | October 18, 2018 | Volume: 144 | Issue: 3_Supplement | Pages: 1896-1896

10.1121/1.5068309

Acoustic radiation force has been used in many interesting medical and industrial applications in the past two decades. The fact that radiation stress can be confined to a small focal area and exerted remotely inside or on an object allows one to use this phenomenon in a variety of ways to explore properties of the object. Vibro-acoustography is a material characterization and imaging method that uses harmonic or impulsive acoustic radiation force to stimulate the targeted material and receives the resulting acoustic response. The output acoustic signal is then used to extract important information about the object. Biomedical applications of vibro-acoustography and its closely related methods include imaging, flow detection, and tissue characterization. Other applications include non-destructive evaluation/testing of materials, modal analysis of small structures, and microscopy. This talk presents an overview of vibro-acoustography and its closely related techniques over the past 20 years. Various biomedical and industrial applications will be presented. The talk will conclude with a discussion on potential future applications of this technology.
Three-dimensional shear wave elastography for differentiation of breast lesions: An initial study with quantitative analysis using three orthogonal planes

Clinical Hemorheology and Microcirculation | May 29, 2018 | Volume: 71 | Issue: 3 | Pages: 311-324

10.3233/ch-180388 | PMID 29865044

Using mean frequency estimation algorithms for unambiguous identification and visualization of an acoustically active catheter

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1930-1930

10.1121/1.5036307

Minimally invasive procedures using ultrasound are becoming prominent, especially in applications like biopsy, catheter guidance, and surgeries. In our previous work a catheter tip is fitted with a miniature omnidirectional piezoelectric crystal; the ultrasonic field from the imaging array and the piezoelectric crystal interact resulting in a symmetric Doppler shift. Previously, a frequency domain algorithm was used to identify pixels having the symmetric Doppler shift. The identified pixels can then be visualized on B-mode and color map with a unique color thus representing the location of the catheter tip. However, frequency domain algorithms are computationally expensive and require changes to data workflow. Using mean frequency estimators with symmetric Doppler shift results in the catheter tip being displayed as zero mean noise making it hard to distinguish from color Doppler noise. To overcome this limitation, complex demodulation can be used. Modulating the time domain signal with sine and cosine by the piezoelectric excitation frequency and summing them up results in cancellation of one of the symmetric Doppler components. With only one frequency component remaining mean frequency estimators can be used to identify the location of the catheter. The presented algorithm has lower computational complexity and requires minimal change in software design.
Multi-resolution rank analysis for non-contrast ultrasound imaging of slow flow

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1901-1901

10.1121/1.5036188

While conventional filtering techniques can effectively exclude tissue-related Doppler shifts from those resulting from blood motions in large vessels (flow rates ~ cm/s), significant spectral overlap can hinder proper clutter filtering in imaging slow flows (flow rates ~ mm/s or tenths of mm/s). Recently, several groups have proposed clutter filtering via processing of echo ensembles in the rank space instead of frequency domain. Though significant Doppler content can result from fast moving tissues, global coherence of the induced variations enables a low rank representation. In this talk, we first provide a brief overview of the low rank clutter removal methods. We then present a new framework for the analysis of Doppler ensembles using multi-linear decomposition of a tensor comprising Doppler ensembles at different rates. The model results in a high dimensional tensor from which, after proper rank selection, images of flow at different speeds can be extracted along different fibers. Using simulation models, we demonstrate the superior performance of the proposed method over singular value clutter filtering in imaging small vessels embedded in moving tissue undergoing both translational and shearing motions. We also present in vivo examples where the proposed method provides significant blood to clutter + noise ratio enhancement compared to singular value clutter filtering.
Quantitative morphological analysis of microvasculature in thyroid nodules using non-contrast high-resolution Doppler imaging

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1901-1902

10.1121/1.5036190

We hypothesize that pattern of microvasculature in the thyroid nodules can be a biomarker of thyroid cancer. In this study, morphological features of microvasculature networks are assessed as potential biomarkers for differentiation of benign, suspicious and malignant thyroid nodules. This prospective study included n = 81 patients, with a total of 61 benign, 12 suspicious and 8 malignant nodules verfied by pathology and cytology findings. Thyroid nodules were first identified using conventional B-mode ultrasound. A sequence of raw ultrasound data were acquired from each nodule site in two perpendicular planes at ~600 frames/sec. Power Doppler image of the microvasculature was formed using singular value decomposition clutter removal filtering. Gross images were further processed using a combination of morphology and Hessian-based vessel enhancement filtering. Background-free images of the microvasculature networks were segmented (vessels segment length >385μm and diameter >90μm) for morphological analysis. Using a Bayesian framework, measures of vessels density, diameter and tortuosity were tested for significant differences in the three groups. Among all measures, the probability of vessel diameter >600μm in benign cases was significantly higher than that in malignant cases with the p-value <0.01 using Wilcoxon-Rank-Sum test, suggesting reliable cancer detection performance of the proposed method. [Acknowledgment: NIH Grant EB17213.]
Quantifying nonlinear elasticity modulus of tissue-like solids using acoustic radiation force

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035900

As shown in a recent study, estimation of the magnitude of the acoustic radiation force (ARF) in isotropic tissue-like solids is the key to measuring a third-order nonlinear modulus of elasticity (C)—responsible for coupling the shear and volumetric constitutive responses of a material. Due to experimental limitations, a direct measurement of the ARF in tissue is however difficult. To overcome this problem, we deploy 3D elastodynamic finite element (EFE) simulations of the ARF experiment in tissue-mimicking phantoms to estimate (i) the “background” shear modulus from the phase of the induced shear waves; (ii) the ARF magnitude from the shear wave amplitude, and (iii) the modulus C from the knowledge of the ARF. In this way, by interpreting the ARF-generated shear waves through the prism of 3D-EFE simulations, we facilitate local estimation of the nonlinear C modulus with spatial resolution equaling the size of the focal region. We call this method the C-Elastography (CE). In this study, the CE technique is applied to gelatin phantoms containing an agar-based inclusion. The profiles of the C-modulus in phantoms tested demonstrate good correlation with the phantom geometry, showing marked (and sharp) C-contrast at push points acting on the inclusion. [Acknowledgment: NIH-Grant EB23113.]
Vibro-acoustic method for detection of osteopenia and osteoporosis

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1801-1801

10.1121/1.5035894

Early detection of osteopenia and osteoporosis is critical in identifying at-risk groups and manage necessary therapy. In this paper, a new noninvasive and quantitative vibro-acoustic method is proposed for detection of osteoporosis and osteopenia. In this method, we excite the bone by an ultrasound radiation force (URF) pulse. The URF pulse induces a vibration in the bone, resulting an acoustic wave that is received by a hydrophone placed on the skin. This prospective study included n = 23 volunteers. The number of volunteers with osteopenia and osteoporosis were 7, 6, respectively, and the number of volunteers with normal bone was 10. URF excitations were applied at four equi-distance points on the bone. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. In general, the hydrophone signal may be modeled as a superposition of different modes of bone vibration. Based on this model, we used variational mode decomposition (VMD) as an efficient technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions. Statistical analysis demonstrates that osteopenia and osteoporosis bones can be differentiated from normal bone with p< 0.001 using Wilcoxon rank-sum test on estimated velocity of the modes with maximum power.