Abstract Background Variability in meningeal signal has been observed with various tau‐PET tracers. Differences have been observed in sex and age. Furthermore, the potential role of glymphatic clearance in this variability remains unclear. Here we compare meningeal signal of [ 18 F]MK6240 and [ 18 F]FTP tau‐PET tracers in cognitively unimpaired (CU) amyloid‐β‐ (Aβ‐) individuals, in relation to age, sex and glymphatic clearance. Methods 92 CU Aβ‐ (7 CU young [18‐35yo] and 85 CU old) underwent [ 18 F]MK6240 and [ 18 F]FTP tau‐PET scans, structural MRI, and resting‐state functional MRI (rsfMRI). In native space, we defined nine distinct levels representing meningeal regions, organized from those closest to the cortex (1) to those furthest away (9). Glymphatic clearance, measured as gBOLD/CSF coupling, was calculated for each participant; a lower value means a more efficient glymphatic clearance. Associations between meningeal tracer signal and factors such as sex, age, and glymphatic clearance were analyzed using t‐tests and linear regression models. Results All 9 meningeal regions were tested and rendered similar results; we will be showing those for meninges level 2. [ 18 F]MK6240 and [ 18 F]FTP meningeal signal significantly correlated with each other in both sexes (Figure 1). We observed higher [ 18 F]MK6240 meningeal signal in females compared to males while no difference was found for [ 18 F]FTP signal (Figure 2). In females, [ 18 F]MK6240 meningeal signal did not show a significant association with age, whereas in males, a significant relationship was observed. Both males and females exhibited lower [ 18 F]FTP meningeal signal with increasing age (Figure 3A). Additionally, glymphatic clearance was significantly associated with age for females with [ 18 F]MK6240. No significant associations were found in males with [ 18 F]MK6240 or in either sex for [ 18 F]FTP (Figure 3B). Conclusion Our findings demonstrate that meningeal signal of [ 18 F]MK6240 is significantly associated with glymphatic clearance in females, while in males, it is associated with age. In contrast, [ 18 F]FTP signal is primarily influenced by age in both sexes. These results highlight the distinct relationship between [ 18 F]MK6240 signal and glymphatic function in females, while age appears to play a significant role in both males and females for other tracer signal patterns.
Impact of Medication Use on [18F]MK6240 and [18F]Flortaucipir Uptake in Alzheimer's disease
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Quantifying tau aggregates in the human brain can be achieved using Positron Emission Tomography (PET) techniques, which can potentially be affected by binding competition due to medication use. Patients with dementia often have high rates of comorbidities and polypharmacy. Therefore, this study aims to investigate the potential influence of multiple medications on the uptake of the tau tracers MK6240 (MK) and Flortaucipir (FTP). Method Five classes of medications were evaluated: Anti‐Hypertensives, Statins, Anti‐Diabetics, Psychoactive drugs, and NSAIDs (Table 1). We included 292 individuals [170 cognitively unimpaired (CU) Aβ‐negative and 122 cognitively impaired (CI) Aβ‐positive] from the HEAD study (Table 2). We compared MK and FTP SUVR in the Medial Temporal Lobe (MTL) and Neotemporal Cortex (NTC) in individuals on and off medications. The linear regressions that tested associations were corrected for confounding factors, including age, sex, education, and MoCA score. Correction for multiple comparisons was applied using the Bonferroni method (adjusted p ‐value at 0.00125). Result Among CI Aβ‐positive individuals, Anti‐Diabetics were associated with lower SUVR in the NTC for both FTP and MK. However, these associations did not remain significant after correction for multiple comparisons. (Table 3). Conclusion Our findings indicate that there are no significant associations between the use of the medications studied and MK or FTP uptake when accounting for covariates and applying multiple comparison corrections.
Imaging‐neuropathology evaluation of Amyloid Related Imaging Abnormality sulcal effusion in a DIAN‐TU‐001 participant treated with gantenerumab
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Amyloid related imaging abnormality edema (ARIA‐E) occurs in about 19% of individuals with autosomal dominant Alzheimer disease (ADAD) treated with an anti‐amyloid‐b monoclonal antibody (Salloway et al., 2021). In a previously reported case, ARIA‐E appeared to colocalize with decreases in PiB‐PET uptake (Joseph‐Mathurin, Llibre‐Guerra, et al, 2022), suggesting an association between amyloid‐b (Aβ) removal and ARIA‐E. Here, we compare longitudinal neuroimaging and corresponding neuropathology in an ADAD individual treated with gantenerumab, who experienced multiple ARIA‐E episodes as sulcal effusions that resolved by the end of the four‐year trial. Methods PiB‐PET and MRI were collected pre‐ and post‐randomization (2 and 4 years). The participant consented to brain donation, which was received a year after trial completion. Four tissue samples were taken from the location of the ARIA‐E in the parieto‐occipital left hemibrain as identified by MRI (one block contained the sulcus affected by ARIA‐E; the rest of the coronal section was captured in the remaining three blocks). Area fractions (AFs) of Aβ (10D5 immunohistochemistry (IHC)), tauopathy (PHF1), microglia (Iba1), and astrocytes (GFAP) in one sulcal region of interest (ROI) from each block and PiB‐PET SUVRs of corresponding ROIs were extracted ( n = 4, Figure 1). Additionally, we included PiB‐PET SUVRs corresponding to ARIA‐E findings observed in the right hemisphere at baseline, two‐year, and four‐year visits ( n = 6). Results Overall PiB‐PET uptake increased during the first two years (before ARIA‐E) and decreased during the last two years (including ARIA‐E episodes) (0.03±0.05 vs. ‐0.04±0.04 SUVR/year, p ‐value=0.01, Figure 2). The decrease seemed more pronounced in ARIA‐E ROIs versus normal‐appearing sulcus ROIs (‐0.05±0.04 vs. ‐0.02±0.03 SUVR/year). Lower PiB uptake at last visit appeared associated with lower Aβ AF (estimates=0.03±0.01, p ‐value=0.07). The ARIA‐E ROI had an Aβ AF of 0.009 while normal‐appearing sulcus ROIs had a mean of 0.02+0.003 (Figure 3). AFs for tauopathy, microglia, and astrocytes were within the range of those of normal‐appearing sulcus ROIs, suggesting an Aβ‐specific effect, although unexamined markers may play a role. Conclusions Our preliminary findings indicated that ARIA‐E is associated with longitudinal PiB‐PET decrease and Aβ AF, supporting the link between ARIA‐E, changes in PiB‐PET, and local Aβ removal observed at autopsy. Funding : K01AG080123; U01AG042791; R01AG046179; R01AG053267
Head‐to‐head trajectories of MK6240, Flortaucipir, and plasma
p
‐tau217 as a function of Aβ
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Tau PET tracers present distinct binding characteristics that might influence their trajectories and relationship with other biomarkers along the AD continuum. In a head‐to‐head study, we investigated the relationship between the emergence of PET tracers MK6240 and Flortaucipir, and plasma p ‐tau217 abnormalities as a function of Aβ PET deposition. We further assessed the concordance between tau PET and plasma p ‐tau217 positivity and its relationship with cognitive scores. Method We evaluated 352 individuals from the HEAD study (205 cognitively unimpaired and 147 cognitively impaired) with Aβ PET, MK6240 and Flortaucipir tau PET, and plasma p ‐tau217 (ALZpath) and GFAP (Quanterix) measures. Tau PET Braak regions, plasma p ‐tau217 trajectories were modeled as functions of Aβ burden (Centiloid scale) using the Lowess method. Biomarkers were z‐scored anchored on young individuals ( n = 19, < 28 years old) as anchors. Tau PET (Braak 1 region) and plasma p ‐tau217 were considered positive/abnormal when surpassing 2.5 z‐score. Result Among the tested markers, MK6240 was the earliest to show abnormality as a function of Centiloid, occurring at 22 Centiloids, followed by plasma p ‐tau217 at 38 Centiloid and Flortaucipir at Centiloid 56 (Figure 1). Tau PET and plasma p ‐tau217 positivity showed an overall high concordance (∼80% for both tracers; Figure 2). In MK6240 discordant cases, most individuals were MK6240+/ p ‐tau217‐ (13.8%), while 6.6% were MK6240‐/ p ‐tau217+ (Figure 2A). For Flortaucipir, 15% of discordant cases were Flortaucipir‐/ p ‐tau217+, while 4.8% were Flortaucipir+/ p ‐tau217‐ (Figure 2B). The discordant groups present higher Centiloid than the ptau217‐/Tau‐ group and overall decreased scores in cognitive tests, except for p ‐tau217+/MK6240‐ group (Figure 3). Conclusion MK6240 becomes abnormal at lower levels of Aβ burden compared to plasma p ‐tau217 and Flortaucipir. The relatively high prevalence of discordant tau PET positive or plasma p ‐tau217 positive and suggests that some individuals may show tau PET positivity first, while others may exhibit plasma p ‐tau217 positivity first. The distinct cognitive profiles of this groups suggest potential clinical relevance, warranting further investigation.
Head‐to‐Head evaluation of plasma
p
‐tau217 associations with MK6240, Flortaucipir, PI2620, and RO948 tau PET tracers
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Tau phosphorylation and aggregation are hallmark features of Alzheimer's disease pathology(AD). Previous studies have shown that plasma phosphorylated tau( p ‐tau) at threonine 217 can detect AD‐related tau tangle pathology. However, the head‐to‐head association between p ‐tau217 and different tau PET tracers remains unexplored. Here, we conducted a head‐to‐head comparison of the association between plasma p ‐tau217 and four distinct tau PET tracers[MK6240, Flortaucipir(FTP), PI2620, RO948]. Method We studied 338 individuals across the AD continuum from the HEAD study[190 cognitively unimpaired elderly(CU), 109 with mild cognitive impairment(MCI), and 39 with dementia] with available FTP, MK6240, and plasma p ‐tau217 measured by ALZpath assay. A subset of 64 individuals(28 CU, 25 MCI, and 11 dementia) also had PI2620 and RO948, and p ‐tau217 measured by Lumipulse. The strength of the association was determined using t‐value maps from regression models testing the association between each tau PET tracer and plasma p ‐tau217, and the extent was measured by the percentage of significant voxels(t‐value>3.2). R‐square metric was used to determine how much of the variance in tau PET tracer estimates was explained by plasma p ‐tau217 concentrations. Associations between p ‐tau217 with tau PET were evaluated using the Spearman test. Result We found that in CU, both the extent and magnitude of the association with plasma p ‐tau217 were higher for MK6240 compared to FTP (Figures 1A‐D). Plasma p ‐tau217 explained a greater proportion of the variance in MK6240 than in FTP (Figures 1E‐F). In CI, the extent and magnitude of the association were similar for MK6240 and FTP. Additionally, plasma p ‐tau217 explained a similar proportion of the variance in MK6240 and FTP. Using the subset of individuals who had all tau tracers, MK6240 showed a slightly higher extent of association with p ‐tau217, followed by FTP, PI2620, and RO948 (Figures 2A‐B). The magnitude of association was stronger for MK6240, followed by PI2620, RO948, and FTP (Figures 2C‐D). Plasma p ‐tau217 explained a greater proportion of the variance in MK6240, followed by FTP, RO948, and PI2620 (Figures 2E‐F). We compared the associations between different p ‐tau217 assays, and both assays presented similar associations with all tau PET tracers (Figure 3). Conclusion In summary, our results indicate that the four tau PET tracers exhibit robust associations with plasma p ‐tau217 in similar topographical regions.
Harmonization of Flortaucipir, MK6240, PI2620 and RO948 with the Uniτ scale
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Precise cross‐tracer harmonization of tau PET imaging is essential for comparing tau burden across different tracers and studies. Here, we evaluated the performance of the universal tau PET scale (Uniτ) in harmonizing Flortaucipir, MK6240, PI2620, and RO948 tau PET images into a universal scale. Method We assessed 485 individuals across aging and AD spectrum scanned head‐to‐head with Flortaucipir and MK6240, and a subset of 90 individuals with additional PI2620 and RO948. We generated tau PET SUVRs using the inferior cerebellar gray matter as reference with a common 8mm FWHM. We estimated Uniτ parameters on a training set ( n = 200) by fitting a smoothed hyperbolic tangent equation to the Meta‐Temporal ROI anchored in the mean SUVR of young participants and the 90th percentile from cognitively impaired individuals. We compared tau positivity on the Uniτ scale with classifications from SUVRs (mean + 3 SD from Youngs). We applied the same equation to all brain voxels to generate Uniτ 3D images. Then, we extracted mean Uniτ values for key ROIs and correlated them with ROI‐based Uniτ values to evaluate voxel‐wise estimates. Result Using tracer‐specific parameters, Uniτ harmonized Flortaucipir, MK6240, PI2620, and RO948 to the same scale, aligning values near the identity line and confirming its applicability across tau PET tracers (Figure 1). For Flortaucipir, Uniτ tau positivity matched original SUVR classifications (ground truth), with only one mismatch for MK6240 (Figure 1). Applying the Uniτ transformation to all brain voxels effectively harmonized 3D images to a common scale, reducing visual variabilities (Figure 2). Furthermore, ROI‐based estimates and those extracted from the 3D Uniτ images were identical (Figure 3). Conclusion Our results indicate that tau PET tracers can be harmonized to a common scale using a large head‐to‐head dataset. The Uniτ scale can harmonize entire 3D tau PET images, suggesting that there is no need to use pre‐established ROIs, which would constrain the analysis to a few brain regions. Uniτ is freely accessible across platforms ( www.unitau.app ) for ROI and 3D tau PET harmonization.
Effects of AD modifiable risk factors to tau‐PET tracer uptake and its association with cognitiion in early Braak stages
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Many risk factors can contribute to the occurrence of Alzheimer`s Disease (AD). However, little is known about the impact of dementia risk factors to the uptake of tau‐PET tracers. Therefore, in this work we aim to investigate the influence of dementia risk factors and comorbidities on 18 F‐Flortaucipir (FTP) and 18 F‐MK6240 (MK) tau‐PET tracers’ uptake. Additionally, we will assess how these factors impact the association of tau‐PET and cognition. Method We accessed 436 individuals across the aging and AD spectrum (251 amyloid negative and 185 amyloid positive) from the HEAD study, with available Aβ‐PET, FTP, MK, and clinical assessments. Linear regression models corrected for age, sex, clinical diagnosis, and study site tested the association of factors with tau‐PET tracers in the medial temporal lobe (MTL). A tau‐PET × risk factor term was added to test the influence of risk factors to the association of tau with cognition. Result In amyloid‐β negative individuals, high BMI were positively associated with the uptake of both FTP and MK, whereas hearing loss were positively associated only with MK in the MTL (Figure 1A). In amyloid‐β positive individuals, high body mass index (BMI), hearing loss and sleep disorders were negatively associated with the uptake of both tau‐PET tracers in the MTL. On the other hand, hypertension showed negative association only with MK uptake (Figure 1B). Using Mini‐Mental State Examination (MMSE) scores as outcome, we observed that amyloid‐β negative individuals with high BMI showed worse cognitive performance as a function of both MK and FTP in the MTL, whereas individuals with vision impairment and hearing loss showed worse cognitive performance as a function of MK only (Figure 2A). Amyloid‐β positive individuals with hypercholesterolemia and hypertension presented worse cognitive performance as a function of both MK and FTP in the MTL (Figure 2B). Conclusion In this preliminary analysis, sleep disorders, hypertension, and high BMI were independently associated with tau‐PET tracer uptake, with the effects varying according to amyloid‐β pathology. These prevalent factors in the elderly also changed the association between tau‐PET and cognition, underscoring the need for further studies to better understand their role in modulating this relationship.
Defining tau PET positivity grey zones for MK6240 and Flortaucipir quantification
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Tau PET measures are inherently continuous and applying dichotomized thresholds introduces conceptual and analytical idiosyncrasies. Understanding the limitations in the transition from tau‐negative to tau‐positive classifications is crucial for the effective use of these thresholds. This study aims to determine the confidence levels of tau PET thresholds of abnormality for different tau PET tracers by characterizing their "gray zone" using the universal tau PET scale (Uniτ, www.unitau.app ). Method We evaluated 485 individuals across the aging and AD spectrum from the HEAD study, with head‐to‐head scans for MK6240 and Flortaucipir. Uniτ estimates were derived from the Meta‐Temporal ROI. Tau positivity (T+) was defined as Uniτ values exceeding the mean plus 3 SD of individuals younger than 28 years ( n = 24). Two physicians independently performed a visual assessment of tau positivity for each tracer, with agreement indicating clear tau pathology (TVR+). Logistic regression was used to estimate the probability of TVR+ across Uniτ values for each tracer ( n = 189, CU elderly Aβ‐ and CI Aβ+). Individuals were classified as negative, positive, or within a "gray zone" between the most liberal T+ threshold and varying TVR+ probability thresholds (50%, 75%, 90%, 95%, and 99%). Result The Uniτ gray zone, defined as a function of TVR+ probabilities, demonstrated consistency between the two tracers, with differences observed only in the decimal range. The most liberal Uniτ threshold for T+ was 11.0 for both MK6240 and Flortaucipir, closely matching the 50% TVR+ probability threshold (11.1 for MK6240 and 11.7 for Flortaucipir). Higher TVR+ probabilities corresponded to increased Uniτ values with MK6240 and Flortaucipir showing near‐identical values between the tracers: 14.2 and 14.8 for 75%, 17.3 and 17.9 for 90%, 19.4 and 19.9 for 95%, and 24.1 and 24.6 for 99%, respectively (Figure 1). In total, 26 participants fell within the gray zone for MK6240, compared to 47 participants for Flortaucipir. Conclusion These findings highlight the potential of Uniτ to provide a standardized approach for assessing tau positivity across tracers. By combining quantitative Uniτ measures with visual assessments, we enhance the understanding of tau positivity certainty, particularly in the transition between negative and positive classifications.
Assessing Braak stage agreement between four Tau PET tracers
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background The Alzheimer's disease (AD) Braak staging is a key framework for classifying tau pathology progression in AD based on histopathological post‐mortem brain examinations. However, adapting it to PET imaging can be challenging due to differences in tracer uptake patterns and binding properties, which affect sensitivity, specificity, and regional staging. This study compares Braak staging across four tau PET tracers: Flortaucipir, MK6240, PI2620, and RO948. Methods We assessed 90 participants across the AD spectrum (46 CU, 31 MCI, 13 dementia; mean age 66.1 ± 7.8) using Aβ PET and four tau PET tracers: (Flortaucipir, MK6240, PI2620, and RO948). Braak positivity was defined based on Aβ− CU individuals (mean +2.5 SD, SUVR). To evaluate systematic bias and agreement between tracers, we computed pairwise differences at corresponding Braak stage estimates and applied the Bland‐Altman method to assess mean bias and limits of agreement. Additionally, Tau PET Braak region trajectories were modeled as functions of Aβ burden (Centiloid scale) using the Lowess method. Results Braak stage trajectories as a function of Aβ differ depending on the tracer and the sequential order of abnormality is highly variable. For instance, while for MK6240, RO948 and PI2620, Braak I is the first region to became abnormal, for Flortaucipir the earliest region to became abnormal is Braak IV (Figure 1). This variable pattern of abnormality impacts in the concordance of Braak staging between tracers with the highest Braak staging agreement resulting in concordance levels of approximately 70%. The highest levels of agreement between tracers usually happen at Braak 0 or Braak IV‐V, with intermediate stages showing very low concordance (Figure 2). The Bland‐Altman analysis identified wide limits of agreement, suggesting high variability and high tracer‐specific differences (Figure 3). On the other hand, it also identified that mean differences between tracers were small, indicating minimal systematic bias. Conclusion These preliminary findings reveal discrepancies in Braak staging when comparing Flortaucipir, MK6240, PI2620 and RO948. These findings suggest that while the tracers provide comparable stages on average, they may not be fully interchangeable in individual cases.
In vivo
detectability of tau‐PET tracers in Alzheimer’s disease
Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available
Abstract Background Tau‐PET tracers are essential for visualizing pathology in Alzheimer’s (AD). High detectability to tau is crucial for early detection and monitoring of tau deposition. This study compares the noise to dynamic range ratio (NRR) of [ 18 F]FTP, [ 18 F]MK6240, [ 18 F]PI2620, and [ 18 F]RO948, cross‐sectionally and longitudinally. Methods 460 individuals from the HEAD study (23 cognitively unimpaired (CU) young, 249 CU old and 188 cognitively impaired) underwent [ 18 F]FTP and [ 18 F]MK6240 tau‐PET scans; 94 additionally received [ 18 F]PI2620 and [ 18 F]RO948. A subset of 28 individuals (15 CU and 13 CI) underwent [ 18 F]FTP and [ 18 F]MK6240 follow‐up scans (1.5 ± 0.1 years later). Annual change was measured as [(followup‐baseline)/time between scans]. Noise was calculated as the standard deviation (SD) of CU Aβ‐ participants aged ≤65 (SD CUAβ‐≤65 ). The dynamic range was calculated as the SD across all subjects (SD range ). A lower the NRR (=SD CUAβ‐≤65 /SD range ) indicates more detectability. Analyses were performed at both region‐of‐interest and voxel‐wise levels. Results Across the whole cohort, [ 18 F]MK6240 exhibited lower NRR than [ 18 F]FTP in all regions. Voxel‐wise, differences were most pronounced in the frontal medial temporal regions (Figure 1). Within the four‐tracers subset, [ 18 F]PI2620 and [ 18 F]FTP showed the highest NRR in Braak II, followed by [ 18 F]RO948 and [ 18 F]MK6240. In Braak IV‐VI, [ 18 F]MK6240 consistently demonstrated the lowest values, followed by [ 18 F]PI2620, [ 18 F]FTP and [ 18 F]RO948. Similarly, in metatemporal‐ROI and Braak III, [ 18 F]MK6240 remained the lowest, however followed by [ 18 F]FTP, [ 18 F]PI2620 and [ 18 F]RO948 (Figure 2). Lower [ 18 F]MK6240 NRR was due to larger SD range , while [ 18 F]FTP's lower values stemmed from smaller SD CUAβ‐≤65 . Conversely, high [ 18 F]PI2620 and [ 18 F]RO948 values are driven by larger SD CUAβ‐≤65 . Longitudinal analyses further confirmed that [ 18 F]MK6240 exhibited the lowest NRR across the entire brain, including AD‐related regions, with voxel‐wise differences mainly in the temporal and parietal lobes. Conclusion Tau‐PET tracers exhibit significant variability in detectability. [ 18 F]MK6240 consistently demonstrated lower NRR, implying better detectability across all regions, cross‐sectionally and longitudinally. Despite differences in NRR, [ 18 F]FTP, [ 18 F]RO948 and [ 18 F]PI2620 followed similar pattern. These results provide insights into the differential tracer detectability, helping guide their optimal use in detecting and tracking tau pathology. Ongoing follow‐up scans will further clarify longitudinal tracer detectability and its implications for tau progression in AD.