Interaction between the electrical system of implanted cardiovascular devices and electrical stimulation of acupuncture points (electro-acupuncture) can be life-threatening. As a result, there is reluctance to use this modality in patients who have been implanted with any cardiac device. A patient with a total artificial heart was successfully treated with electro-acupuncture for inflammatory arthritis without any adverse events. This case illustrates the safety of electro-acupuncture in patients with a total artificial heart.
Severe Left Atrial Appendage Stunning After Electrical Cardioversion of Atrial Fibrillation
Circulation | November 17, 2008 | Volume: 118 | Issue: 21 | Pages: No page available
Patients with hypertension exhibit impaired energetic coupling between the ventricle and the arterial system, leading to reduced cardiac mechanic efficiency and exercise capacity. We tested whether blood pressure normalization with current antihypertensive therapy can improve arterioventricular coupling. Eighteen hypertensive patients without other cardiovascular disease were examined before and after antihypertensive therapy. Transthoracic echocardiography was performed. Central aortic pressure waveforms, including end-systolic pressure, were derived from radial artery applanation tonometry. Afterload was increased with isometric handgrip exercise. Central aortic end-systolic pressure and ventricular volumes at rest and handgrip were used to calculate ventricular elastance, effective arterial elastance, arterioventricular coupling (effective arterial elastance/ventricular elastance), and mechanical efficiency. After 142±67 days, systolic blood pressure decreased from 150.9±14.6 to 119.8±9.2 mm Hg ( P <0.00001), diastolic blood pressure from 85.9±14.8 to 68.8±8.4 mm Hg ( P =0.00002), and cardiac output from 5.8±1.7 to 4.9±1.8 L/min ( P =0.03). Resting left ventricular end-systolic volume, ejection fraction, and septal thickness did not change. Ventricular elastance increased from 1.7±1.0 to 3.2±1.4 mm Hg/mL ( P =0.00002), whereas effective arterial elastance decreased from 1.4±0.5 to 1.2±0.4 mm Hg/mL ( P =0.02). Effective arterial elastance/ventricular elastance decreased in all patients, from 1.1±0.8 to 0.4±0.2 ( P =0.0002). Efficiency improved at rest (72.9±5.8% versus 83.5±5.7%; P <0.00001) and during handgrip (63.5±7.8% versus 78.9±7.1%; P <0.00001). In hypertensive patients, optimal brachial and central blood pressure reduction shifts arterioventricular coupling from cardiac output maximization to ventricular mechanical efficiency optimization. This occurs before significant changes in ventricular geometry and may be responsible for early clinical improvements.
Intracardiac Thrombosis and Embolism in Patients With Cardiac Amyloidosis
Background— Patients with primary amyloidosis (AL type) have a poor prognosis, in part due to frequent cardiac involvement. Although intracardiac thrombus has been reported in anecdotal cases, neither its frequency nor its role in causing mortality is known. Furthermore, the clinical and echocardiographic variables that may be associated with thromboembolism in cardiac amyloidosis have not been defined. Methods and Results— A total of 116 autopsy or explanted cases of cardiac amyloidosis (55 AL and 61 other type) were identified in the Mayo Clinic. Forty-six fatal nonamyloid trauma cases served as controls. Each heart was examined for intracardiac thrombus. The cause of death was determined from autopsy and clinical notes. Intracardiac thrombosis was identified in 38 hearts (33%). Twenty-three had 1 thrombus, whereas 15 had 2 to 5 thrombi. Although subjects in the AL group were younger and had less atrial fibrillation than those with other types of amyloidosis, the AL group had significantly more intracardiac thrombus (51% versus 16%, P <0.001) and more fatal embolic events (26% versus 8%, P <0.03). Control hearts had no intracardiac thrombus. The presence of both atrial fibrillation and AL was associated with an extremely high risk for thromboembolism (odds ratio 55.0 [95% confidence interval 8.1 to 1131.4]). By multivariate analysis, AL type (odds ratio 8.4 [95% confidence interval 1.8 to 51.2]) and left ventricular diastolic dysfunction (odds ratio 12.2 [95% confidence interval 2.7 to 72.7]) were independently associated with thromboembolism. Conclusions— A high frequency of intracardiac thrombosis was present in cardiac amyloidosis. Furthermore, thromboembolism caused significant fatality. Several risk factors for thromboembolism were identified. Early screening, especially in high-risk patients, and early anticoagulation might reduce morbidity and mortality.
Scimitar Syndrome
Circulation | September 4, 2006 | Volume: 114 | Issue: 10 | Pages: No page available