Back to Authors

Drislane, Frank W.

0000-0002-1855-0882

A5090223824 | I1316535847

Mayo Clinic

Beth Israel Deaconess Medical Center

Citations 10

Revised Process for ACNS Guidelines Development

Journal of Clinical Neurophysiology | January 30, 2025 | Volume: 42 | Issue: 2 | Pages: 95-100

10.1097/wnp.0000000000001133 | PMID 39883486

Summary: The development of clinical practice guidelines is an evolving field. In response to the need for consistent, evidence-based medical practice, the American Clinical Neurophysiology Society identified the need to update the Society's guideline development process. The American Clinical Neurophysiology Society Guidelines Committee created an action plan with the goal of improving transparency and rigor for future guidelines and bringing existing guidelines to current standards. This article provides an overview of the new American Clinical Neurophysiology Society standards for the creation of clinical guidance documents, including clinical guidelines, technical standards, and consensus statements. This process is rooted in the importance of clinical guidance documents and their significance in the context of current behests for updated standards for practicing clinical neurophysiology. The need and rationale for updating the guideline development process from its prior state were described. The updated American Clinical Neurophysiology Society categories for clinical guidance and recommendations were defined and compared. Finally, the new process is summarized, focusing on methodologies, authorship, and conflicts of interest.
Minimum Technical Requirements for Performing Ambulatory EEG

Journal of Clinical Neurophysiology | June 15, 2022 | Volume: 39 | Issue: 6 | Pages: 435-440

10.1097/wnp.0000000000000950 | PMID 35916885

Summary: Ambulatory EEG (AEEG) devices offer portable, multichannel, digital EEG recording with or without video in the patient's natural environment. The technology applied for AEEG recording is like the technology for routine EEG and inpatient long-term video-EEG monitoring but designed to be compact and wearable. Computer-based AEEG technology is well-suited to digital recording, signal processing, and visual display. However, acquiring interpretable EEG outside of the hospital setting presents its own technical challenges. Published guidelines have established technical standards for performing routine EEG and inpatient video-EEG monitoring, but technical standards for AEEG are lacking. Therefore, this guideline provides minimal technical standards for the performance of AEEG which are essential to ensure the quality of studies for clinical and research practice. We expect these minimum standards to evolve over time with improved performance and advances in the technology.
American Clinical Neurophysiology Society's Standardized Critical Care EEG Terminology: 2021 Version

Journal of Clinical Neurophysiology | January 20, 2021 | Volume: 38 | Issue: 1 | Pages: 1-29

10.1097/wnp.0000000000000806 | PMID 33475321

American Clinical Neurophysiology Society Guideline 6: Minimum Technical Standards for EEG Recording in Suspected Cerebral Death

The Neurodiagnostic Journal | January 4, 2017 | Volume: 56 | Issue: 4 | Pages: 276-284

10.1080/21646821.2016.1245575 | PMID 28436789

American Clinical Neurophysiology Society: EEG Guidelines Introduction

The Neurodiagnostic Journal | January 4, 2017 | Volume: 56 | Issue: 4 | Pages: 231-234

10.1080/21646821.2016.1245513 | PMID 28436786

American Clinical Neurophysiology Society Guideline 7: Guidelines for EEG Reporting

The Neurodiagnostic Journal | January 4, 2017 | Volume: 56 | Issue: 4 | Pages: 285-293

10.1080/21646821.2016.1245576 | PMID 28436792

American Clinical Neurophysiology Society Guideline 6: Minimum Technical Standards for EEG Recording in Suspected Cerebral Death

Journal of Clinical Neurophysiology | August 9, 2016 | Volume: 33 | Issue: 4 | Pages: 324-327

10.1097/wnp.0000000000000322 | PMID 27482789

Summary: This revision to the EEG Guidelines is an update incorporating current EEG technology and practice. The role of the EEG in making the determination of brain death is discussed as are suggested technical criteria for making the diagnosis of electrocerebral inactivity.
American Clinical Neurophysiology Society Guideline 7: Guidelines for EEG Reporting

Journal of Clinical Neurophysiology | August 9, 2016 | Volume: 33 | Issue: 4 | Pages: 328-332

10.1097/wnp.0000000000000319 | PMID 27482790

Summary: This EEG Guideline incorporates the practice of structuring a report of results obtained during routine adult electroencephalography. It is intended to reflect one of the current practices in reporting an EEG and serves as a revision of the previous guideline entitled “Writing an EEG Report.” The goal of this guideline is not only to convey clinically relevant information, but also to improve interrater reliability for clinical and research use by standardizing the format of EEG reports. With this in mind, there is expanded documentation of the patient history to include more relevant clinical information that can affect the EEG recording and interpretation. Recommendations for the technical conditions of the recording are also enhanced to include post hoc review parameters and type of EEG recording. Sleep feature documentation is also expanded upon. More descriptive terms are included for background features and interictal discharges that are concordant with efforts to standardize terminology. In the clinical correlation section, examples of common clinical scenarios are now provided that encourages uniformity in reporting. Including digital samples of abnormal waveforms is now readily available with current EEG recording systems and may be beneficial in augmenting reports when controversial waveforms or important features are encountered.
American Clinical Neurophysiology Society: EEG Guidelines Introduction

Journal of Clinical Neurophysiology | August 9, 2016 | Volume: 33 | Issue: 4 | Pages: 301-302

10.1097/wnp.0000000000000315 | PMID 27482792

Summary: This revision to the EEG Guidelines is an update incorporating current EEG technology and practice. “Standards of practice in clinical electroencephalography” (previously Guideline 4) has been removed. It is currently undergoing revision through collaboration among multiple medical societies and will become part of “Qualifications and Responsibilities of Personnel Performing and Interpreting Clinical Neurophysiology Procedures.” The remaining guidelines are reordered and renumbered.
Use of simulation in acute neurology training: Point and counterpoint

Annals of Neurology | July 7, 2015 | Volume: 78 | Issue: 3 | Pages: 337-342

10.1002/ana.24473 | PMID 26150374