Citations 54

Quantitative susceptibility mapping of substantia nigra in dementia with Lewy bodies

Alzheimer's & Dementia | December 7, 2020 | Volume: 16 | Issue: S4 | Pages: No page available

10.1002/alz.046236

AbstractBackgroundNeurodegeneration of the substantia nigra in dementia with Lewy bodies is associated with iron deposition, which increases the magnetic susceptibility of the substantia nigra on MRI. The objective of this study was to measure the magnetic susceptibility of the substantia nigra in patients with dementia with Lewy bodies (DLB) and patients with mild cognitive impairment with at least one core feature of DLB (MCI‐DLB) compared to cognitively unimpaired controls (CU) by quantitative susceptibility mapping (QSM).MethodWe studied clinically diagnosed patients with DLB (n=36), patients with MCI‐DLB (n=16), and age‐, gender‐matched CU (n=104) in a case‐control study. MR images used for QSM were performed on 3T MRI with a multi‐echo (5 echoes) 3D gradient recalled echo sequence with a bipolar‐readout. Three‐dimensional regions of interest (ROIs) of bilateral substantia nigra, based on the DISTAL atlas, were propagated from the Mayo Clinic Adult Lifespan Template (MCALT) to each subject’s T1 image using ANTs nonlinear registration. The mean susceptibility values of the substantia nigra were extracted by aligning each subjects QSM image to their T1 image and corresponding ROIs with a 6 DOF rigid registration.ResultThe mean susceptibility values of the substantia nigra bilaterally was 0.110 ± 0.026 for DLB, 0.099 ± 0.028 for MCI‐DLB and 0.091 ± 0.025 for controls (Figure 1). No difference was found across the mean susceptibility from left, right and combined bilateral substantia nigra. Compared to controls, patients with DLB had higher susceptibility in the substantia nigra (p<0.001). The susceptibility of substantia nigra showed an increasing trend from controls to MCI‐DLB and to DLB (p<0.001). There was no correlation between the Unified Parkinson's Disease Rating Scale (UPDRS) and the mean susceptibility in the substantia nigra in patients with MCI‐DLB and DLB (r=0.03; p=0.82).ConclusionQuantitative susceptibility mapping is sensitive to the increased magnetic susceptibility due to higher iron content in the substantia nigra in DLB. The trend of increasing susceptibility from CU to MCI‐DLB and to DLB suggests that iron deposition in the substantia nigra starts to increase as early as the prodromal stage in DLB and continues to increase as the disease progresses independent of the severity of Parkinsonism.
Popular MRI de‐facing software does not sufficiently protect participants from re‐identification via face recognition

Alzheimer's & Dementia | December 7, 2020 | Volume: 16 | Issue: S4 | Pages: No page available

10.1002/alz.045157

AbstractBackgroundData shared for research use must be de‐identified to protect participant confidentiality. A recent study has shown that face imagery from brain imaging studies could be used to re‐identify anonymous participants via automatic face recognition, linking them with all study‐collected protected health information. Here we measure how well existing software for removing MRI face imagery protects against this privacy threat.MethodWe recruited 153 participants with existing 3D FLAIR MRI and photographed their face from 5 varying angles. We used surf_ice to reconstruct each participant’s face from their MRI and tested whether free, publicly‐available face recognition software (Microsoft Azure) could match their photos to their correct MRI. We tested two existing programs for removing face voxels in MRI: mri_deface (FreeSurfer) and pydeface (python package), and one in‐house implementation. We observed that existing methods often left participants’ eyes intact while removing most of their nose/mouth/chin. This prevented Azure from detecting the reconstructions as faces, therefore preventing its attempt of face recognition. We hypothesized that the retained eye imagery alone could be sufficient for face recognition, if a face were detected. Therefore, we also reconstructed each de‐faced MRI after applying novel pre‐processing that replaced any removed/missing face voxels with those from our population‐average template, e.g. replacing missing noses/mouths/chins with population‐average noses/mouths/chins, before testing face recognition.ResultsWithout any MRI de‐facing, Microsoft Azure correctly matched 78% of participants’ photos to their MRI. After mri_deface and pydeface, 8% and 6% were still identified, respectively. After preprocessing the de‐faced MRI to replace missing areas with those from a population‐average template prior to face reconstruction, the face imagery remaining in the de‐faced images was enough to allow re‐identification of 23% and 20% of participants, respectively. With an in‐house face removal implementation that removes the whole face from every image, 0% of faces were re‐identified from the standard reconstructions, and 5% were identified from the “missing‐parts‐replacement” reconstructions.ConclusionsEven after applying popular MRI de‐facing software, Microsoft Azure face recognition automatically re‐identified up to 23% of participants. Better de‐facing software is needed to remove more of the face more reliably, without affecting brain measurements from de‐faced images.
TURBINE‐MRE: A 3D hybrid radial‐Cartesian EPI acquisition for MR elastography

Magnetic Resonance in Medicine | August 1, 2020 | Volume: 85 | Issue: 2 | Pages: 945-952

10.1002/mrm.28445 | PMID 32738084

PurposeTo develop a novel magnetic resonance elastography (MRE) acquisition using a hybrid radial EPI readout scheme (TURBINE), and to demonstrate its feasibility to obtain wave images and stiffness maps in a phantom and in vivo brain.MethodThe proposed 3D TURBINE‐MRE is based on a spoiled gradient‐echo MRE sequence with the EPI readout radially rotating about the phase‐encoding axis to sample a full 3D k‐space. A polyvinyl chloride phantom and 6 volunteers were scanned on a compact 3T GE scanner with a 32‐channel head coil at 80 Hz and 60 Hz external vibration, respectively. For comparison, a standard 2D, multislice, spin‐echo (SE) EPI‐MRE acquisition was also performed with the same motion encoding and resolution. The TURBINE‐MRE images were off‐line reconstructed with iterative SENSE algorithm. The regional ROI analysis was performed on the 6 volunteers, and the median stiffness values were compared between SE‐EPI‐MRE and TURBINE‐MRE.ResultsThe 3D wave‐field images and the generated stiffness maps were comparable between TURBINE‐MRE and standard SE‐EPI‐MRE for the phantom and the volunteers. The Bland–Altman plot showed no significant difference in the median regional stiffness values between the two methods. The stiffness measured with the 2 methods had a strong linear relationship with a Pearson correlation coefficient of 0.943.ConclusionWe demonstrated the feasibility of the new TURBINE‐MRE sequence for acquiring the desired 3D wave‐field data and stiffness maps in a phantom and in‐vivo brains. This pilot study encourages further exploration of TURBINE‐MRE for functional MRE, free‐breathing abdominal MRE, and cardiac MRE applications.
Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T

NMR in Biomedicine | December 19, 2019 | Volume: 34 | Issue: 5 | Pages: No page available

10.1002/nbm.4218 | PMID 31854045

Abstract The semi‐adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single‐shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high‐ and ultra‐high fields. Across‐vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B 1 requirements of the adiabatic inversion pulses and maximum B 1 limitations on some platforms. The aims of this study were to design a short‐echo sLASER sequence that can be executed within a B 1 limit of 15 μT by taking advantage of gradient‐modulated RF pulses, to implement it on three major platforms and to evaluate the between‐vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel‐based first and second order B 0 shimming and voxel‐based B 1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient‐modulated pulses considered (GOIA, FOCI and BASSI), GOIA‐WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B 1 of 15 μT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter‐pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE ‘Braino’ phantom between vendors. High‐quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal‐to‐noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi‐site studies with clinical cohorts.
Modernizing Storage Conditions for Fresh Osteochondral Allografts by Optimizing Viability at Physiologic Temperatures and Conditions

CARTILAGE | November 28, 2019 | Volume: 13 | Issue: 1_suppl | Pages: 280S-292S

10.1177/1947603519888798 | PMID 31777278

Objective. Osteochondral allograft (OCA) transplantation has demonstrated good long-term outcomes in treatment of cartilage defects. Viability, a key factor in clinical success, decreases with peri-implantation storage at 4°C during pathogen testing, matching logistics, and transportation. Modern, physiologic storage conditions may improve viability and enhance outcomes. Design. Osteochondral specimens from total knee arthroplasty patients (6 males, 5 females, age 56.4 ± 2.2 years) were stored in media and incubated at normoxia (21% O 2 ) at 22°C or 37°C, and hypoxia (2% O 2 ) at 37°C. Histology, live-dead staining, and quantitative polymerase chain reaction (qPCR) was performed 24 hours after harvest and following 7 days of incubation. Tissue architecture, cell viability, and gene expression were analyzed. Results. No significant viability or gene expression deterioration of cartilage was observed 1-week postincubation at 37°C, with or without hypoxia. Baseline viable cell density (VCD) was 94.0% ± 2.7% at day 1. At day 7, VCD was 95.1% (37°C) with normoxic storage and 92.2% (37°C) with hypoxic storage ( P ≥ 0.27). Day 7 VCD (22°C) incubation was significantly lower than both the baseline and 37°C storage values (65.6%; P < 0.01). COL1A1, COL1A2, and ACAN qPCR expression was unchanged from baseline ( P < 0.05) for all storage conditions at day 7, while CD163 expression, indicative of inflammatory macrophages and monocytes, was significantly lower in the 37°C groups ( P < 0.01). Conclusion. Physiologic storage at 37°C demonstrates improved chondrocyte viability and metabolism, and maintained collagen expression compared with storage at 22°C. These novel findings guide development of a method to optimize short-term fresh OCA storage, which may lead to improved clinical results.
Identification of Anonymous MRI Research Participants with Face-Recognition Software

New England Journal of Medicine | October 23, 2019 | Volume: 381 | Issue: 17 | Pages: 1684-1686

10.1056/nejmc1908881 | PMID 31644852

Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 | PMID 30101999

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
MRI feature tracking strain is prognostic for all-cause mortality in AL amyloidosis

Amyloid | May 7, 2018 | Volume: 25 | Issue: 2 | Pages: 101-108

10.1080/13506129.2018.1465406 | PMID 29733684

Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 | PMID 29194738

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
[P4–242]: ADNI‐3 MRI ACQUISITIONS

Alzheimer's & Dementia | October 20, 2017 | Volume: 13 | Issue: 7S_Part_28 | Pages: No page available

10.1016/j.jalz.2017.06.2110